136G4953 Danfoss VLT HVAC Drive 11 kW/15HP 380-480VAC IP55

136G4953 Danfoss VLT HVAC Drive 11 kW/15HP 380-480VAC IP55

Danfoss 136G4953 VLT HVAC Drive FC 102, an 11 kW 15 HP three-phase AC variable frequency drive with IP55 Type 12 protection, mains disconnect and Modbus TCP communication for HVAC pumps, fans, compressors and building automation applications.

SKU: 136G4953Alt SKU: FC-102P11KT4E55H1XGC1XXSXXXXAQBXCXXXXDXMPN: 136G4953
Price
List Price £2,894.00 ex VAT
Your Price (ex VAT) Save 45%
£1,591.70 45% OFF
You save £1,302.30 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,591.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,591.70

Danfoss 136G4953 at a glance

The Danfoss 136G4953 is an 11 kW / 15 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame B1, IP55 / UL Type 12 unit, built for wall mounting in plant rooms without a separate enclosure.

This configuration has RFI class A1/B (C1), no brake chopper, a graphical LCP 102 control panel, and a Modbus TCP MCA 122 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP55 / UL Type 12 — built for wall mounting in plant rooms without a separate enclosure.
  • EMC: RFI class A1/B (C1). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive11 kWDanfoss 136G4953IP55 / UL Type 12 · frame B1
Larger30 kWDanfoss 136G4954IP55 / UL Type 12 · frame B2View drive →

Same 11 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 11 kW
Current 21 A
Voltage 480 V
Phase Three Phase
IP Rating IP55
EMC Filter Commercial
Series VLT HVAC Drive FC 102
Full model code FC-102P11KT4E55H1XGC1XXSXXXXAQBXCXXXXDX
Product type AC variable frequency drive
Rated output power 11 kW / 15 HP
Rated current 21 A
Input voltage 380–480 V AC
Input phases 3-phase
Output phases Three phase
Frequency 50 / 60 Hz
Protection rating IP55 / Type 12
Frame size B1
Control panel Graphical local control panel
Brake chopper No brake chopper
Communication option Modbus TCP MCA 122
PCB protection Coated PCB
Mains option Mains disconnect
Dimensions (H × W × D) approx. 494 × 243 × 261 mm
Net weight approx. 21.1 kg
EAN 5710108614072

Frequently asked questions

Which communication protocols does it support?

This unit is fitted with a Modbus TCP MCA 122 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

Can this drive be wall mounted without a panel?

Yes. The IP55 / UL Type 12 enclosure is designed for direct mounting.

Type code decoded

FC-102P11KT4E55H1XGC1XXSXXXXAQBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
11 kW / 15 HPP11K
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP55 / UL Type 12E55
RFI filter
Position 16–17
RFI class A1/B (C1)H1
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Conformal-coated PCBsC
Mains option
Position 21
Mains disconnect1
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
Modbus TCP MCA 122AQ
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX