Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 486181200060SPA – 48 Series Relay interface modules.
The Finder 486181200060SPA, also identified as 48.61.8.120.0060SPA, is a compact 16 A modular relay interface designed for industrial automation, PLC interfacing and electrical control applications. Part of the Finder Series 48, this complete relay and socket assembly combines a 120 V AC operating coil, single-pole changeover (SPDT / 1 CO) contacts and convenient 35 mm DIN rail mounting.
Featuring a 16 A rated contact current and 250 V AC rated switching voltage, the Finder 486181200060SPA provides a practical interface between control signals and electrical loads. Its changeover contact configuration supports normally open and normally closed switching functions, making it suitable for machinery control, auxiliary switching, signalling and industrial automation systems.
The module incorporates screw terminal connections, an LED status indicator and varistor coil suppression to support convenient wiring, visual monitoring and protection against switching-related voltage transients. With a slim 15.8 mm housing width, the relay interface helps conserve DIN rail space while providing dependable electromechanical switching.
The Finder 486181200060SPA provides a convenient method of switching electrical loads using a 120 V AC control circuit. Its single-pole changeover contact allows one control signal to operate either a normally open or normally closed circuit, supporting a wide range of industrial control, signalling and auxiliary switching functions.
The integrated LED status indicator provides visual confirmation of the control supply, helping maintenance personnel identify relay activation conditions during inspection and troubleshooting. The varistor suppression circuit helps manage transient voltages generated during coil switching, making the module suitable for integration into compatible electronic and industrial control systems.
Its compact DIN rail-mounted construction supports efficient electrical cabinet layouts, while the screw terminal socket provides accessible connections for installation and maintenance. For applications involving currents above 10 A, the manufacturer's specified parallel contact terminal connections must be followed to achieve the applicable 16 A rating.
Tick the specs you need, then view products that match.
| Device Type | Interface Relay | |
|---|---|---|
| Terminal Type | Screw | |
| Load Voltage | 400 V AC | |
| Mounting Type | DIN rail | |
| Switching Current (A) | 16 A | |
| Manufacturer | Finder | |
| Series | 48 | |
| Relay interface type | 48.61 | |
| Model / SKU | 486181200060SPA | |
| Alternative manufacturer reference | 48.61.8.120.0060SPA | |
| Product type | Modular electromechanical relay interface | |
| Nominal coil voltage | 120 V AC | |
| Coil supply frequency | 50/60 Hz | |
| Coil operating voltage range | 96–132 V AC | |
| Nominal coil consumption | 1.2 VA at 50 Hz | |
| Contact configuration | SPDT / 1 CO | |
| Number of changeover contacts | 1 | |
| Number of poles | 1 | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated AC1 resistive load | 4,000 VA | |
| Contact material | Silver cadmium oxide (AgCdO) | |
| Relay operating principle | Electromechanical, monostable | |
| Mounting method | 35 mm DIN rail | |
| Connection type | Screw terminals | |
| Relay socket | Included | |
| Status indication | Integrated LED | |
| Coil suppression | Integrated varistor | |
| Operating temperature | −40 °C to +70 °C | |
| Degree of protection | IP20 | |
| Width | 15.8 mm | |
| Height | 78.6 mm | |
| Depth | 71.8 mm | |
| EAN | 8012823246505 | |
| Application | Industrial automation and electrical control interface switching |
The Finder 486181200060SPA is a modular electromechanical relay interface used for electrical switching in industrial automation systems, PLC interfaces, electrical control panels and machinery control circuits.
The relay interface operates from a 120 V AC nominal control supply at 50/60 Hz. Its specified coil operating voltage range is 96–132 V AC.
The module features a 16 A rated contact current, a 250 V AC rated contact voltage and a maximum switching voltage of 400 V AC. For currents exceeding 10 A, the manufacturer's required parallel contact terminal connections must be used.
Yes. The Finder 486181200060SPA is supplied as a complete relay interface assembly with socket, featuring screw terminal connections, an integrated LED status indicator and varistor coil suppression.
The module is designed for 35 mm DIN rail mounting within a suitable electrical enclosure. It uses screw terminal connections and has a compact housing measuring approximately 15.8 mm wide, 78.6 mm high and 71.8 mm deep.
The Finder 486181200060SPA combines a 120 V AC coil, 16 A changeover contacts, LED indication and varistor suppression in a compact DIN rail-mounted interface, providing practical switching functionality for industrial automation, electrical control panels and electronic control systems.
Product availability note: This exact part number has been listed as obsolete by a major electronic component distributor. Confirm current availability and any proposed replacement before ordering.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.