Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 486181201060SPA DIN rail interface relay module from the 48 Series, featuring a 120 V AC nominal control supply, single changeover contact and plug-in electromechanical relay construction for industrial automation and electrical control applications.
The Finder 486181201060SPA, formatted as 48.61.8.120.1060SPA, is a Finder 48 Series industrial interface relay module designed for convenient switching and control in electrical panels, industrial machinery and automation systems. Combining a plug-in electromechanical relay with a DIN rail socket, this type of interface module provides a practical connection between control equipment and electrical loads.
Designed around a 120 V AC nominal control voltage, the Finder 486181201060SPA is intended for compatible AC control circuits. The 48.61 relay family features a single changeover contact, providing both normally open and normally closed switching functions. This makes the module useful for auxiliary switching, equipment control, status signalling and electrical interlocking applications.
The 48.61.8.120.1060SPA reference identifies a specific relay interface assembly within Finder's modular range. The 48.61 family is associated with 16 A changeover relay technology, while the complete assembly provides a convenient format for DIN rail installation and maintenance. Before selecting the product for a particular load, the exact socket rating, accessory configuration and manufacturer's technical data should be checked against the full part number.
The Finder 486181201060SPA is intended to simplify electrical switching where a 120 V AC control circuit needs to operate a separate contact circuit. When the relay coil is energised, the common contact transfers from the normally closed terminal to the normally open terminal. Removing the control voltage allows the relay to return to its normal position.
This single changeover contact provides flexibility for equipment control. The normally open connection can be used where a circuit should activate when the relay is energised, while the normally closed connection can be used where a circuit should remain connected until the relay operates. Both functions share a common contact, so they must be designed and wired in accordance with the relay's electrical ratings.
The modular DIN rail arrangement is particularly useful in industrial control panels. It provides an accessible interface between incoming control wiring and outgoing load wiring, while the removable relay format supports maintenance without replacing the entire socket assembly. Correct socket selection, conductor sizing and protective devices remain essential for reliable operation.
Finder's 48 Series interface relay platform is designed for installations where conventional electromechanical switching must be integrated into compact electrical control assemblies. Interface relays can help control engineers organise wiring, separate control and load circuits and provide replaceable switching components within an electrical enclosure.
The Finder 486181201060SPA is particularly relevant to systems using a 120 V AC control supply. When specifying this product, engineers should distinguish it from otherwise similar 48.61 modules designed for 110 V AC, 230 V AC or DC operation. The correct nominal coil voltage is essential for dependable operation and to avoid damage to the relay.
Tick the specs you need, then view products that match.
| Device Type | Interface Relay | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 48 Series | |
| Relay family | 48.61 | |
| Product SKU | 486181201060SPA | |
| Formatted part number | 48.61.8.120.1060SPA | |
| Product category | Industrial interface relay module | |
| Relay technology | Electromechanical | |
| Nominal control voltage | 120 V AC | |
| Control supply type | AC | |
| Contact configuration | Single-pole double-throw (SPDT / 1 CO) | |
| Number of changeover contacts | 1 | |
| Normally open contact | Yes | |
| Normally closed contact | Yes | |
| Common contact | Yes | |
| Relay family rated contact current | 16 A | |
| Relay family rated contact voltage | 250 V AC | |
| Relay operating mode | Monostable / non-latching | |
| Contact switching action | Electromagnetically operated changeover | |
| Mounting method | DIN rail socket assembly | |
| Relay replacement | Plug-in arrangement | |
| Typical DIN rail standard | 35 mm mounting rail | |
| Electrical connections | Via the interface socket | |
| Application environment | Industrial electrical control enclosures | |
| Control and load circuits | Electrically separated through the relay mechanism | |
| Primary applications | Control panel switching, auxiliary control and industrial automation | |
| Exact assembly contact rating | Verify against the complete Finder part-number datasheet and socket rating |
The Finder 486181201060SPA is a DIN rail interface relay module intended for electrical switching in industrial automation, control panels and machinery. It provides a changeover contact operated by a 120 V AC control supply.
The part-number designation identifies a 120 V AC nominal control voltage. The relay should be operated only from a compatible AC supply within the manufacturer's specified voltage and frequency limits. It must not be treated as a 120 V DC relay.
1 CO means one changeover contact, also described as SPDT (single-pole double-throw). The relay has a common terminal that switches between normally closed and normally open contact positions when the coil is energised.
The Finder 48.61 relay family is associated with a 16 A contact rating. The permitted current for the complete 486181201060SPA assembly must also take account of the supplied socket, wiring and load category. Always verify the complete module rating before switching high-current loads.
The module is intended for installation on a compatible DIN rail inside a suitable electrical enclosure. Control and load wiring connect through the relay socket, and the plug-in relay can be removed for servicing. The exact terminal layout and accessory arrangement should be checked against the manufacturer's documentation before installation.
Finder 48 Series interface relays provide a practical approach to electrical switching in industrial automation and control panel applications. The Finder 486181201060SPA offers a 120 V AC control interface, a single changeover contact and a convenient DIN rail mounting arrangement, making it a useful option for electrical engineers, panel builders and maintenance professionals seeking a compact, serviceable relay solution.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.