Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
66.82.9.024.0601 Finder Power relay 2pole 30A DC 24V.
The Finder 66.82.9.024.0601 is a heavy-duty 30 A industrial electromechanical power relay featuring a 24 V DC operating coil and two normally open contacts (DPST-NO / 2 NO). Part of the established Finder 66 Series, this relay is designed for high-current electrical switching in industrial machinery, automation systems, heating equipment and electrical control assemblies.
The relay incorporates two normally open contacts that operate simultaneously when the electromagnetic coil is energised. Its 1.5 mm contact gap provides increased contact separation, while its 30 A rated switching current supports demanding industrial load-control applications. The monostable operating mechanism automatically returns both contacts to their open positions when coil power is removed.
A distinguishing feature of the 66.82.9.024.0601 is its wash-tight construction (RT III), designed to provide enhanced protection against cleaning processes during equipment manufacturing. Combined with silver-cadmium oxide (AgCdO) contacts, flange mounting and Faston 250 quick-connect terminals, this relay offers a practical solution for OEM equipment manufacturers, maintenance engineers and industrial automation professionals.
The Finder 66.82.9.024.0601 enables two electrical load circuits to be controlled using a single 24 V DC control signal. When the coil is energised, both normally open contacts close simultaneously, completing their respective circuits. When coil power is removed, both contacts open automatically. This provides a straightforward solution for industrial control systems that require two circuits to operate together while maintaining electrical isolation between the control coil and switched contacts.
The Finder 66 Series is designed for industrial power switching applications requiring robust contacts and practical installation. The 66.82.9.024.0601 combines 30 A contacts, a 1.5 mm contact gap, RT III wash-tight construction and flange-mounted Faston connections. The wash-tight construction is particularly relevant to suitable OEM manufacturing processes; it should not be interpreted as an IP-rated waterproof enclosure or permission to expose an energised relay to liquids.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Switching Current (A) | 30 A | |
| Load Voltage | 440 V AC | |
| Manufacturer | Finder | |
| Series | 66 Series Power Relays | |
| Model | 66.82.9.024.0601 | |
| Product type | Electromechanical power relay | |
| Contact configuration | 2 normally open contacts (DPST-NO / 2 Form A) | |
| Number of contacts | 2 normally open contacts | |
| Nominal coil voltage | 24 V DC | |
| Coil supply type | DC | |
| Operating principle | Monostable / non-latching | |
| Nominal DC coil consumption | 1.7 W | |
| Nominal coil resistance | 340 Ω | |
| Calculated nominal coil current | Approximately 70.6 mA | |
| Rated contact current | 30 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 440 V AC | |
| Rated AC1 switching capacity | 7,500 VA | |
| Contact material | Silver-cadmium oxide (AgCdO) | |
| Contact gap | 1.5 mm | |
| Dielectric strength between coil and contacts | 4,000 V AC | |
| Typical operate time | 8 ms | |
| Typical release time | 10 ms | |
| Operating ambient temperature | −40 to +70 °C | |
| Environmental protection category | RT III (wash tight) | |
| Mounting type | Flange / chassis mounting | |
| Terminal arrangement | Faston quick-connect terminals | |
| Terminal type | Faston 250 | |
| Terminal dimensions | 6.3 × 0.8 mm | |
| Approximate overall dimensions | 68.5 × 33.5 × 31 mm | |
| RoHS compliance | Yes |
The Finder 66.82.9.024.0601 is an industrial electromechanical power relay used to switch electrical loads in machinery, automation systems, heating equipment and control assemblies. It features two normally open contacts rated at 30 A, operated by a 24 V DC coil.
The relay requires a 24 V DC nominal coil supply. Its nominal coil consumption is 1.7 W, with a coil resistance of approximately 340 Ω and a calculated nominal current of approximately 70.6 mA.
The relay features two normally open contacts rated at 30 A, with a rated contact voltage of 250 V AC and a maximum switching voltage of 440 V AC. Its rated AC1 switching capacity is 7,500 VA. Permissible loads depend on the switching category and operating conditions.
Both relays feature a 24 V DC coil, two normally open 30 A contacts and a 1.5 mm contact gap. The key difference is the environmental protection version: the 66.82.9.024.0601 has RT III wash-tight construction, while the 66.82.9.024.0600 is the standard RT II flux-proof version. The mounting and electrical specifications should also be checked before substitution.
The relay is designed for flange or chassis mounting and uses Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm. It should be installed using suitably rated connectors, wiring and protective devices. Its RT III wash-tight construction is intended for appropriate manufacturing conditions and does not replace the need for a suitable electrical enclosure.
Finder 66 Series power relays are designed for dependable high-current switching in industrial machinery, automation and electrical control equipment. The Finder 66.82.9.024.0601 combines a 24 V DC coil, two 30 A normally open contacts, a 1.5 mm contact gap and RT III wash-tight construction with practical flange-mounted Faston connections, making it a suitable choice for demanding OEM and industrial electrical switching applications.