66.82.9.024.4601 Finder Power relay 2pole 30A DC 24V

66.82.9.024.4601 Finder Power relay 2pole 30A DC 24V

Finder 66.82.9.024.4601 is a 30 A industrial electromagnetic power relay with a 24 V DC coil, two normally open contacts, a minimum 1.5 mm contact gap, RT III wash-tight construction, top flange mounting and Faston 250 quick-connect terminals.

SKU: 66.82.9.024.4601Alt SKU: 668290244601MPN: 66.82.9.024.4601
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 66.82.9.024.4601 Power Relay?

The Finder 66.82.9.024.4601 is a heavy-duty 30 A industrial electromagnetic power relay designed for reliable high-current switching in industrial machinery, automation systems and electrical control equipment. Part of the Finder 66 Series, this model combines a 24 V DC operating coil, two normally open contacts (DPST-NO) and an increased contact gap of at least 1.5 mm.

The 66.82.9.024.4601 features RT III wash-tight construction, offering additional environmental protection during suitable manufacturing washing processes. It also incorporates top flange mounting and Faston 250 quick-connect terminals, making it practical for installation in electrical enclosures and machinery without direct PCB soldering.

Its combination of a 24 V DC control coil, high-current contacts, increased open-contact separation and reinforced coil-to-contact insulation makes this relay particularly useful in demanding electrical switching applications. The 1.5 mm minimum contact gap is especially relevant to equipment designs requiring enhanced separation between open contacts, including suitable photovoltaic inverter applications.

Key Advantages

  • 30 A rated contact current for demanding industrial electrical loads.
  • 24 V DC operating coil for compatible low-voltage DC control systems.
  • 2 NO (DPST-NO) contacts allow simultaneous switching of two independent circuits.
  • Minimum 1.5 mm contact gap provides increased separation between open contacts.
  • RT III wash-tight construction offers additional protection during suitable manufacturing processes.
  • Top flange mounting enables secure mechanical installation.
  • Faston 250 quick-connect terminals simplify wiring, maintenance and replacement.
  • Reinforced insulation between the coil and contacts.
  • 8 mm creepage and clearance distances support robust electrical separation.
  • 6 kV coil-to-contact impulse withstand voltage in the Finder 66 Series insulation design.
  • Suitable for industrial machinery, power control equipment and appropriately designed photovoltaic systems.

Key Features

  • Finder 66 Series industrial power relay.
  • 24 V DC nominal coil voltage.
  • 2 NO (DPST-NO) contact configuration.
  • Minimum 1.5 mm open-contact gap.
  • 30 A rated contact current.
  • Silver cadmium oxide (AgCdO) contact material.
  • RT III wash-tight environmental protection.
  • Top flange mounting arrangement.
  • Faston 250 terminals measuring 6.3 × 0.8 mm.
  • 250 V AC rated contact voltage.
  • Approximately 1.7 W nominal DC coil consumption.
  • 24 V DC coil operating range of approximately 19.2–26.4 V DC.
  • Reinforced coil-to-contact insulation.
  • Non-latching electromagnetic operation.
  • Increased-gap contact design associated with photovoltaic inverter switching requirements.

Wash-Tight Power Switching with Increased Contact Separation

The Finder 66.82.9.024.4601 uses a 24 V DC electromagnetic coil to control two normally open power contacts. When the coil is energised, both contacts close, allowing current to flow through the connected circuits. When the coil supply is removed, the contacts return to their normally open positions.

The 4601 configuration combines two important characteristics: a minimum 1.5 mm open-contact gap and RT III wash-tight construction. The increased contact gap provides greater physical separation between open contacts, while the wash-tight enclosure offers additional protection during suitable manufacturing washing processes. RT III classification does not mean that the relay is intended for permanent immersion, pressure washing or unrestricted outdoor exposure.

The increased-gap design is relevant to applications such as photovoltaic inverter switching, where specific contact separation requirements may apply. However, the relay must be assessed as part of the complete equipment design; its contact gap alone does not establish compliance with every isolation, disconnection or photovoltaic safety requirement.

The 66.82 flange-mounted housing and Faston 250 connections make this relay suitable for machinery and electrical assemblies requiring secure mechanical installation and detachable wiring. As with any power relay, the connected load type, inrush current, switching frequency and operating temperature must be considered when confirming suitability.

Typical Applications

  • Industrial automation and electrical control panels.
  • Photovoltaic inverter switching and power control assemblies.
  • Industrial machinery requiring increased contact separation.
  • Manufacturing equipment and machine controllers.
  • Industrial heating and temperature control systems.
  • Boiler and burner control equipment.
  • Air conditioning, ventilation and HVAC systems.
  • Commercial laundry and industrial washing equipment.
  • Electrical power distribution and auxiliary switching circuits.
  • OEM equipment requiring wash-tight, flange-mounted relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 30 A
Manufacturer Finder
Series 66 Series Power Relays
Model 66.82.9.024.4601
Product type Industrial electromagnetic power relay
Relay operation Non-latching
Contact configuration 2 NO (DPST-NO)
Number of poles 2
Open-contact gap ≥ 1.5 mm
Contact material Silver cadmium oxide (AgCdO)
Nominal coil voltage 24 V DC
Coil supply type DC
Nominal DC coil consumption 1.7 W
Approximate nominal coil resistance 340 Ω
Approximate nominal coil current 71 mA
Coil operating voltage range 19.2–26.4 V DC
Rated contact current 30 A
Rated contact voltage 250 V AC
Rated AC1 switching capacity 7,500 VA
Coil-to-contact impulse withstand voltage 6 kV (1.2/50 µs)
Coil-to-contact dielectric strength 4,000 V AC
Coil-to-contact creepage and clearance 8 mm
Insulation type Reinforced insulation between coil and contacts
Mechanical life, series nominal 10 million operations
Electrical life at rated AC1 load, series nominal 100,000 operations
Ambient operating temperature, series range −40 to +70 °C
Environmental protection category RT III, wash-tight
Mounting type Top flange mounting
Terminal type Faston 250 quick-connect terminals
Terminal dimensions 6.3 × 0.8 mm
Approximate overall dimensions 68.5 × 33.5 × 31 mm
Contact circuit option 6 – Normally open contacts with ≥ 1.5 mm contact gap
Special version 1 – Wash-tight RT III
Applicable relay standard EN 61810-1

Frequently Asked Questions

What is the Finder 66.82.9.024.4601 used for?

The Finder 66.82.9.024.4601 is a 30 A industrial electromagnetic power relay used to switch electrical loads in machinery, automation systems and power control equipment. Its increased contact gap and wash-tight construction make it particularly useful in equipment designs requiring additional open-contact separation and environmental protection.

What coil voltage does the Finder 66.82.9.024.4601 require?

The relay uses a 24 V DC nominal operating coil with approximately 1.7 W nominal coil consumption. Its nominal operating voltage range is approximately 19.2–26.4 V DC. It is a DC coil relay and should not be connected directly to an AC control supply.

What does the 4601 suffix mean on the Finder 66.82.9.024.4601?

The 4601 suffix identifies a relay with silver cadmium oxide contacts, a normally open contact arrangement with a gap of at least 1.5 mm, and an RT III wash-tight special version. These characteristics distinguish it from standard-contact-gap and standard-enclosure versions.

What is the difference between the Finder 66.82.9.024.4600 and 66.82.9.024.4601?

Both models use a 24 V DC coil and two normally open contacts with a minimum 1.5 mm contact gap. The principal difference is environmental protection: the 4600 is the standard version, while the 4601 is the RT III wash-tight version.

How is the Finder 66.82.9.024.4601 mounted and connected?

The relay uses top flange mounting and Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm. This allows it to be fixed securely to suitable equipment structures and wired using compatible quick-connect receptacles.

Trusted by Industrial Automation and Electrical Equipment Manufacturers

Finder 66 Series power relays offer robust electrical switching for industrial machinery, automation systems and OEM equipment. The Finder 66.82.9.024.4601 combines a 24 V DC coil, 30 A normally open contacts, increased contact separation, RT III wash-tight construction, reinforced insulation and flange-mounted Faston connections for demanding power control applications.