66.82.8.230.0003 Finder Power relay 2pole 30A 230V.
The Finder 66.82.8.230.0003 is an industrial electromechanical power relay from the Finder 66 Series, designed for electrical load switching, machinery control and industrial automation applications. Featuring a 230 V AC operating coil and two normally open contacts (2 NO), this relay provides a practical solution for controlling two separate electrical circuits through a common AC control signal.
The Finder 66.82.8.230.0003 combines a dual-contact switching arrangement with electromagnetic relay technology. Its two normally open contacts allow separate electrical circuits to be switched together, making it suitable for auxiliary load control, equipment operation and industrial electrical switching applications.
As part of Finder's established 66 Series power relay family, this model is intended for equipment requiring AC-controlled switching. The complete 66.82.8.230.0003 manufacturer part number identifies the specific relay variant and should be used when selecting replacement components or specifying relays for new electrical installations.
The Finder 66.82.8.230.0003 provides an electromechanical interface between a 230 V AC control circuit and two separately connected electrical loads. When the operating coil is energised, the relay's electromagnetic mechanism closes both normally open contacts, completing the connected circuits. When coil power is removed, the contacts return to their open positions.
The 2 NO contact configuration is useful where one control command must operate two electrical circuits. For example, one contact may control an auxiliary load while the other operates a separate equipment function. This arrangement can simplify control wiring in compatible industrial machinery, electrical panels and automation equipment.
Before installation, engineers should verify the contact current rating, switching voltage, load category, inrush current, coil frequency, terminal arrangement, mounting requirements and any special characteristics of the .0003 variant against Finder documentation for the exact part number. The 230 V AC coil rating specifies the nominal operating supply and does not determine the permissible voltage across the relay contacts. Suitable circuit protection and safe isolation procedures are essential when working with mains-voltage control circuits.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 66 Series | |
| Manufacturer part number | 66.82.8.230.0003 | |
| Product category | Industrial electromechanical power relay | |
| Relay technology | Electromechanical | |
| Contact configuration | 2 NO (two normally open contacts) | |
| Number of poles | 2 | |
| Nominal coil voltage | 230 V AC | |
| Coil supply type | Alternating current (AC) | |
| Operating principle | Electromagnetic, monostable | |
| Contact operating arrangement | Two normally open switching circuits | |
| Contact state when de-energised | Both normally open contacts open | |
| Product family | Finder 66 Series Power Relays |
The Finder 66.82.8.230.0003 is an industrial electromechanical power relay used for switching two electrical circuits through a common AC control signal. Typical applications include machinery control, auxiliary load switching and industrial automation equipment.
The relay has a nominal operating coil voltage of 230 V AC. It must be connected to a compatible alternating-current control supply within the manufacturer's specified operating limits. The coil frequency and voltage tolerance should be confirmed before installation.
The relay features two normally open contacts (2 NO). Both contacts are open when the relay is de-energised and close when the operating coil is energised, allowing two separate electrical circuits to be switched together.
No. The Finder 66.82.8.230.0003 uses a monostable electromechanical operating principle. Its normally open contacts close while the coil is energised and return to their open positions when the coil is de-energised.
Before installation, confirm the 230 V AC coil supply, two normally open contact arrangement, applicable switching ratings, coil frequency, terminal configuration, mounting requirements and any special characteristics of the .0003 variant against Finder documentation for the exact part number. Connected loads must remain within the relay's specified operating limits.
Finder 66 Series power relays provide electromechanical switching solutions for industrial machinery, electrical control and automation equipment. The Finder 66.82.8.230.0003 combines a 230 V AC operating coil with two normally open contacts, offering dual-circuit switching for compatible industrial electrical applications.