66.82.8.230.0003 Finder Power relay 2pole 30A 230V

66.82.8.230.0003 Finder Power relay 2pole 30A 230V

66.82.8.230.0003 Finder Power relay 2pole 30A 230V.

SKU: 66.82.8.230.0003Alt SKU: 668282300003MPN: 66.82.8.230.0003
This product has been discontinued A direct replacement is available below.
66.82.8.230.4003 Finder Power relay 2pole 30A 230V Replacement product 66.82.8.230.4003 Finder Power relay 2pole 30A 230V SKU: 66.82.8.230.4003 View

Why Choose the Finder 66.82.8.230.0003 Industrial Power Relay?

The Finder 66.82.8.230.0003 is an industrial electromechanical power relay from the Finder 66 Series, designed for electrical load switching, machinery control and industrial automation applications. Featuring a 230 V AC operating coil and two normally open contacts (2 NO), this relay provides a practical solution for controlling two separate electrical circuits through a common AC control signal.

The Finder 66.82.8.230.0003 combines a dual-contact switching arrangement with electromagnetic relay technology. Its two normally open contacts allow separate electrical circuits to be switched together, making it suitable for auxiliary load control, equipment operation and industrial electrical switching applications.

As part of Finder's established 66 Series power relay family, this model is intended for equipment requiring AC-controlled switching. The complete 66.82.8.230.0003 manufacturer part number identifies the specific relay variant and should be used when selecting replacement components or specifying relays for new electrical installations.

Key Advantages

  • 230 V AC operating coil supports compatible industrial AC control systems.
  • Two normally open contacts (2 NO) enable switching of two separate electrical circuits.
  • Dual-circuit switching allows two electrical loads to respond to a common control signal.
  • Electromechanical operation provides electrical separation between the operating coil and switching contacts.
  • Normally open contact arrangement keeps both switching paths open when the relay is de-energised.
  • Monostable operation returns the contacts to their normal positions when coil power is removed.
  • Industrial power relay design supports integration into machinery and electrical control equipment.
  • Finder 66 Series construction provides an established platform for industrial power switching.
  • Suitable for auxiliary load switching, equipment control and electrical automation.
  • Useful for OEM equipment manufacture and replacement of matching relay variants.

Key Features

  • Finder 66 Series industrial electromechanical power relay.
  • 66.82 configuration with two normally open contacts.
  • 2 NO contact arrangement for dual-circuit switching.
  • 230 V AC nominal coil voltage.
  • Alternating-current electromagnetic coil operation.
  • Two normally open switching paths.
  • Common coil control of both contact sets.
  • Monostable, non-latching operating mechanism.
  • Electrical separation between the coil and contact circuits.
  • Suitable for switching compatible electrical loads within the manufacturer's specified ratings.
  • Designed for industrial machinery, electrical control and automation applications.
  • Identified by the complete manufacturer part number 66.82.8.230.0003.

Reliable 230 V AC Control for Industrial Power Switching

The Finder 66.82.8.230.0003 provides an electromechanical interface between a 230 V AC control circuit and two separately connected electrical loads. When the operating coil is energised, the relay's electromagnetic mechanism closes both normally open contacts, completing the connected circuits. When coil power is removed, the contacts return to their open positions.

The 2 NO contact configuration is useful where one control command must operate two electrical circuits. For example, one contact may control an auxiliary load while the other operates a separate equipment function. This arrangement can simplify control wiring in compatible industrial machinery, electrical panels and automation equipment.

Before installation, engineers should verify the contact current rating, switching voltage, load category, inrush current, coil frequency, terminal arrangement, mounting requirements and any special characteristics of the .0003 variant against Finder documentation for the exact part number. The 230 V AC coil rating specifies the nominal operating supply and does not determine the permissible voltage across the relay contacts. Suitable circuit protection and safe isolation procedures are essential when working with mains-voltage control circuits.

Typical Applications

  • Industrial electrical control panels and automation assemblies.
  • 230 V AC machinery control circuits.
  • Dual-circuit auxiliary power switching.
  • Industrial equipment enable and disable functions.
  • Manufacturing machinery and production equipment.
  • Electrical automation and control systems.
  • Building services and equipment control.
  • Heating, ventilation and air-conditioning control equipment.
  • Pump, fan and process equipment control circuits.
  • OEM machinery and electrical equipment manufacturing.
  • Industrial plant auxiliary switching applications.
  • Maintenance and replacement of matching Finder 66 Series relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Manufacturer Finder
Series 66 Series
Manufacturer part number 66.82.8.230.0003
Product category Industrial electromechanical power relay
Relay technology Electromechanical
Contact configuration 2 NO (two normally open contacts)
Number of poles 2
Nominal coil voltage 230 V AC
Coil supply type Alternating current (AC)
Operating principle Electromagnetic, monostable
Contact operating arrangement Two normally open switching circuits
Contact state when de-energised Both normally open contacts open
Product family Finder 66 Series Power Relays

Frequently Asked Questions

What is the Finder 66.82.8.230.0003 used for?

The Finder 66.82.8.230.0003 is an industrial electromechanical power relay used for switching two electrical circuits through a common AC control signal. Typical applications include machinery control, auxiliary load switching and industrial automation equipment.

What coil voltage does the Finder 66.82.8.230.0003 require?

The relay has a nominal operating coil voltage of 230 V AC. It must be connected to a compatible alternating-current control supply within the manufacturer's specified operating limits. The coil frequency and voltage tolerance should be confirmed before installation.

What contact configuration does the Finder 66.82.8.230.0003 have?

The relay features two normally open contacts (2 NO). Both contacts are open when the relay is de-energised and close when the operating coil is energised, allowing two separate electrical circuits to be switched together.

Is the Finder 66.82.8.230.0003 a latching relay?

No. The Finder 66.82.8.230.0003 uses a monostable electromechanical operating principle. Its normally open contacts close while the coil is energised and return to their open positions when the coil is de-energised.

What should be checked before installing the Finder 66.82.8.230.0003?

Before installation, confirm the 230 V AC coil supply, two normally open contact arrangement, applicable switching ratings, coil frequency, terminal configuration, mounting requirements and any special characteristics of the .0003 variant against Finder documentation for the exact part number. Connected loads must remain within the relay's specified operating limits.

Trusted by Industrial Automation and Control Engineers Worldwide

Finder 66 Series power relays provide electromechanical switching solutions for industrial machinery, electrical control and automation equipment. The Finder 66.82.8.230.0003 combines a 230 V AC operating coil with two normally open contacts, offering dual-circuit switching for compatible industrial electrical applications.