Chint SNE3-1130FS is a 13 A unswitched plastic fused spur with an integrated 30 mA Type A latching RCD, double-pole contact break and 240 V AC rating for protected fixed electrical connections.
£22.09
The Chint SNE3-1130FS is a 13 A unswitched fused spur with integrated Type A RCD protection, designed to provide additional protection against residual currents in domestic, commercial and light industrial electrical installations. Part of the Chint Shield SNE3 series, this plastic fused connection unit combines circuit connection, fuse protection and residual current protection within a compact wall-mounted accessory.
The SNE3-1130FS incorporates a 30 mA Type A latching/passive RCD with double-pole contact break. Type A residual current protection is designed to respond to alternating sinusoidal residual currents as well as pulsating DC residual currents, making the unit suitable for supplying a wide range of modern electrical equipment.
Rated at 13 A and 240 V AC, 50 Hz, the SNE3-1130FS has an RCD operating speed of less than 40 ms, a breaking capacity of 250 A and short-circuit withstand capability of 1,500 A. Its white plastic construction, compact 86 × 86 mm fascia and minimum 35 mm mounting-box depth make it a practical solution for fixed electrical installations requiring local fused and residual current protection.
An RCD fused spur combines the functions of a fused connection unit with residual current protection, providing a convenient local connection point for fixed electrical equipment. The Chint SNE3-1130FS incorporates a 13 A fused connection with a sensitive 30 mA RCD, helping provide additional protection where leakage current to earth is detected.
The Type A RCD and double-pole contact break make the SNE3-1130FS suitable for contemporary electrical installations and equipment containing electronic components. Its passive design means the RCD remains latched following a loss of supply, allowing connected equipment to resume operation when power is restored where this behaviour is appropriate for the installation.
| Manufacturer | Chint |
|---|---|
| Range | Chint Shield |
| Series | SNE3 |
| Model | SNE3-1130FS |
| Product type | RCD fused connection unit / fused spur |
| Configuration | Unswitched |
| Material | Plastic |
| Current rating | 13 A |
| Voltage rating | 240 V AC |
| Frequency | 50 Hz |
| RCD type | Type A |
| RCD operation | Latching / passive |
| Rated tripping current | 30 mA |
| Contact break | Double pole |
| Operating speed | <40 ms |
| Breaking capacity | 250 A |
| Short-circuit withstand | 1,500 A |
| Ambient operating temperature | -5 to +40 °C |
| Minimum box depth | 35 mm |
| Cable capacity | 5 × 2.5 mm² / 2 × 4 mm² / 1 × 6 mm² |
| Dimensions (H × W) | 86 × 86 mm |
| Front plate depth | 14.5 mm |
| Overall mounting depth | 21 mm |
The Chint SNE3-1130FS provides a 13 A fused connection with integrated 30 mA RCD protection for fixed electrical equipment in domestic, commercial and light industrial installations.
The SNE3-1130FS incorporates a Type A latching/passive RCD with a rated residual operating current of 30 mA.
The fused spur is rated at 13 A and 240 V AC, 50 Hz.
The RCD incorporates a double-pole contact break, allowing both live and neutral conductors to be disconnected by the RCD mechanism.
Chint specifies a minimum box depth of 35 mm for the SNE3 series plastic RCD fused spur.
Chint Shield SNE3 RCD sockets and fused spurs combine practical wiring accessory design with 30 mA residual current protection, providing convenient protection solutions for domestic, commercial and light industrial electrical installations.