sne3-1130fs chint rcd fused spur plastic

sne3-1130fs chint rcd fused spur plastic

Chint SNE3-1130FS is a 13 A unswitched plastic fused spur with an integrated 30 mA Type A latching RCD, double-pole contact break and 240 V AC rating for protected fixed electrical connections.

SKU: SNE3-1130FS
Price
List Price £49.08 ex VAT
Your Price (ex VAT) Save 55%
£22.09 55% OFF
You save £26.99 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £22.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£22.09

Why Choose the Chint SNE3-1130FS RCD Fused Spur?

The Chint SNE3-1130FS is a 13 A unswitched fused spur with integrated Type A RCD protection, designed to provide additional protection against residual currents in domestic, commercial and light industrial electrical installations. Part of the Chint Shield SNE3 series, this plastic fused connection unit combines circuit connection, fuse protection and residual current protection within a compact wall-mounted accessory.

The SNE3-1130FS incorporates a 30 mA Type A latching/passive RCD with double-pole contact break. Type A residual current protection is designed to respond to alternating sinusoidal residual currents as well as pulsating DC residual currents, making the unit suitable for supplying a wide range of modern electrical equipment.

Rated at 13 A and 240 V AC, 50 Hz, the SNE3-1130FS has an RCD operating speed of less than 40 ms, a breaking capacity of 250 A and short-circuit withstand capability of 1,500 A. Its white plastic construction, compact 86 × 86 mm fascia and minimum 35 mm mounting-box depth make it a practical solution for fixed electrical installations requiring local fused and residual current protection.

Key Advantages

  • Combines a 13 A fused connection unit and RCD in one compact accessory.
  • Type A RCD protection suitable for modern electrical loads.
  • 30 mA rated tripping current for additional residual current protection.
  • Double-pole contact break disconnects both live and neutral conductors.
  • Latching/passive RCD operation for appropriate fixed-installation applications.
  • Fast <40 ms operating speed.
  • White plastic construction suitable for a wide range of interiors.

Key Features

  • Chint Shield SNE3 series.
  • 13 A unswitched RCD fused spur.
  • Type A residual current protection.
  • 30 mA rated tripping current.
  • 240 V AC, 50 Hz voltage rating.
  • Double-pole contact break.
  • Latching / passive RCD operation.
  • 250 A breaking capacity.
  • 1,500 A short-circuit withstand.
  • <40 ms operating speed.
  • Plastic construction with compact single-gang format.
  • Cable capacity up to 1 × 6 mm².

Integrated RCD and Fused Connection Protection

An RCD fused spur combines the functions of a fused connection unit with residual current protection, providing a convenient local connection point for fixed electrical equipment. The Chint SNE3-1130FS incorporates a 13 A fused connection with a sensitive 30 mA RCD, helping provide additional protection where leakage current to earth is detected.

The Type A RCD and double-pole contact break make the SNE3-1130FS suitable for contemporary electrical installations and equipment containing electronic components. Its passive design means the RCD remains latched following a loss of supply, allowing connected equipment to resume operation when power is restored where this behaviour is appropriate for the installation.

Typical Applications

  • Fixed domestic electrical appliances.
  • Commercial electrical installations.
  • Kitchen and utility equipment supplies.
  • Heating and ventilation equipment.
  • Pumps and fixed electrical equipment.
  • Workshops and light industrial installations.
  • Circuits requiring local fused and 30 mA RCD protection.

Technical Specifications

Manufacturer Chint
Range Chint Shield
Series SNE3
Model SNE3-1130FS
Product type RCD fused connection unit / fused spur
Configuration Unswitched
Material Plastic
Current rating 13 A
Voltage rating 240 V AC
Frequency 50 Hz
RCD type Type A
RCD operation Latching / passive
Rated tripping current 30 mA
Contact break Double pole
Operating speed <40 ms
Breaking capacity 250 A
Short-circuit withstand 1,500 A
Ambient operating temperature -5 to +40 °C
Minimum box depth 35 mm
Cable capacity 5 × 2.5 mm² / 2 × 4 mm² / 1 × 6 mm²
Dimensions (H × W) 86 × 86 mm
Front plate depth 14.5 mm
Overall mounting depth 21 mm

Frequently Asked Questions

What is the Chint SNE3-1130FS used for?

The Chint SNE3-1130FS provides a 13 A fused connection with integrated 30 mA RCD protection for fixed electrical equipment in domestic, commercial and light industrial installations.

What type of RCD is fitted to the SNE3-1130FS?

The SNE3-1130FS incorporates a Type A latching/passive RCD with a rated residual operating current of 30 mA.

What is the current and voltage rating of the SNE3-1130FS?

The fused spur is rated at 13 A and 240 V AC, 50 Hz.

Does the Chint SNE3-1130FS provide double-pole isolation?

The RCD incorporates a double-pole contact break, allowing both live and neutral conductors to be disconnected by the RCD mechanism.

What mounting box depth is required for the SNE3-1130FS?

Chint specifies a minimum box depth of 35 mm for the SNE3 series plastic RCD fused spur.

Reliable Protection for Fixed Electrical Equipment

Chint Shield SNE3 RCD sockets and fused spurs combine practical wiring accessory design with 30 mA residual current protection, providing convenient protection solutions for domestic, commercial and light industrial electrical installations.