BFA03270024 - S-D STARTER 50A 24/50-60 W/O T/O RELAY

BFA03270024 – S-D STARTER 50A 24/50-60 W/O T/O RELAY

Lovato BFA03270024 is a 50 A open-frame star-delta motor starter with 24 V AC 50/60 Hz contactor coils for three-phase motors rated up to 25 kW at 400 V.

SKU: BFA03270024MPN: BFA03270024
Price
List Price £1,058.57 ex VAT
Your Price (ex VAT) Save 40%
£635.14 40% OFF
You save £423.43 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £635.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£635.14

Why Choose the Lovato BFA03270024 Star-Delta Starter?

The Lovato BFA03270024 is a complete open-frame star-delta motor starter designed to reduce starting current when controlling three-phase induction motors. Part of the Lovato Electric BF range, it provides an assembled solution for industrial motor-starting applications requiring dependable electromechanical control.

The starter has a maximum IEC operational current of 50 A and supports three-phase motor ratings up to 25 kW at 400 V AC. Its contactors use a 24 V AC, 50/60 Hz control coil, making the assembly suitable for control circuits operating at this voltage.

Designed for starting periods of up to 12 seconds and a maximum of 30 operations per hour, the BFA03270024 is suitable for controlled-duty industrial machinery. It is supplied without a thermal overload relay, allowing the correct overload device to be selected separately for the motor.

Key Advantages

  • Complete open-frame star-delta starter assembly.
  • Reduces motor starting current compared with direct-on-line starting.
  • 50 A maximum IEC operational current.
  • Supports motor ratings up to 25 kW at 400 V AC.
  • 24 V AC, 50/60 Hz contactor coils.
  • Suitable for starting periods of up to 12 seconds.
  • Pre-assembled format simplifies motor-control panel construction.

Key Features

  • Lovato Electric BF series star-delta starter.
  • Open-frame construction for installation inside an enclosure.
  • 50 A rated operational current.
  • 25 kW AC-3 operational power at 400 V.
  • 15 kW AC-3 operational power at 230 V.
  • 24 V AC control voltage at 50/60 Hz.
  • Maximum starting time of 12 seconds.
  • Maximum operating frequency of 30 operations per hour.
  • Screw connections for main and control circuits.
  • Supplied without a thermal overload relay.

Controlled Starting for Three-Phase Motors

A star-delta starter initially connects a compatible motor’s windings in star configuration to reduce the current drawn during acceleration. After the timed starting period, the circuit changes to delta configuration so the motor can operate at its normal running voltage and power.

This starting method is commonly used where reduced inrush current is required and the driven machine can accelerate with reduced starting torque. The BFA03270024 must be installed with suitable upstream short-circuit protection and a correctly selected thermal overload relay.

Typical Applications

  • Industrial pumps and pumping systems.
  • Fans and ventilation equipment.
  • Compressors with suitable starting characteristics.
  • Conveyors and material-handling systems.
  • Processing and production machinery.
  • Industrial motor-control panels.

Technical Specifications

Tick the specs you need, then view products that match.

Coil / Supply Voltage 24 V AC
HS Code 85371098
Manufacturer Lovato Electric
Series BF
Model BFA03270024
Product type Star-delta motor starter
Construction Open frame
Maximum IEC operational current 50 A
Rated operational power at AC-3, 400 V 25 kW
Rated operational power at AC-3, 230 V 15 kW
Contactor coil voltage 24 V AC
Coil frequency 50/60 Hz
Maximum starting time 12 seconds
Maximum operating frequency 30 operations per hour
UL/CSA motor rating at 480 V 30 hp
Main circuit connection Screw connection
Auxiliary and control circuit connection Screw connection
Protection rating IP20
Width 198 mm
Height 90 mm
Depth 130 mm
Weight 1760 g
Standards IEC/EN 60947-1 and IEC/EN 60947-4-9

Frequently Asked Questions

What is the Lovato BFA03270024 used for?

The BFA03270024 is used to start compatible three-phase induction motors using a star-delta starting sequence that reduces starting current.

What is the maximum operational current of this starter?

The starter has a maximum IEC operational current of 50 A.

What control voltage does the BFA03270024 require?

Its contactors have 24 V AC coils designed for 50/60 Hz supplies.

What motor power can the starter control?

The BFA03270024 is rated for three-phase motors up to 25 kW at 400 V AC under AC-3 operating conditions.

Does the BFA03270024 include a thermal overload relay?

No. The starter is supplied without a thermal overload relay, so a suitable overload device must be selected separately for the motor’s rated current.

Trusted Industrial Motor Control from Lovato Electric

Lovato Electric star-delta starters provide practical, dependable motor-starting solutions for machine builders, panel manufacturers and industrial automation engineers.