ETE XMS50P4S4 is a 50 VA single-phase Class II enclosed safety/isolating transformer with a 240 V AC primary, 110 V AC secondary, Class F insulation, integral moulded housing and DIN rail or chassis mounting options.
£24.68
The ETE XMS50P4S4 is a compact 50 VA single-phase Class II enclosed safety/isolating transformer designed for industrial electrical control panels, machinery, automation equipment and AC control circuits. Part of the ETE XMS enclosed transformer range, it converts a nominal 240 V AC primary supply into a 110 V AC secondary output, providing a practical solution for industrial equipment requiring a lower control voltage.
The XMS50P4S4 features a 0/240 V primary terminal arrangement and a 0/110 V secondary terminal arrangement. Its Class II protective construction and integral moulded housing provide an enclosed transformer design suitable for integration into compatible electrical assemblies. The transformer supports DIN rail or chassis mounting, offering installation flexibility for different control panel layouts.
With a rated apparent power of 50 VA and Class F insulation, the ETE XMS50P4S4 is suitable for appropriately rated 110 V AC control loads. Its compact dimensions of 90 × 106 × 87 mm and weight of 1.3 kg make it a convenient choice for electrical cabinets where installation space is limited. The specified enclosure is an integral moulded housing.
The ETE XMS50P4S4 is designed to convert a nominal 240 V AC input into a 110 V AC output for compatible industrial control and signalling equipment. Its primary winding uses 0/240 V terminals, while its secondary winding uses 0/110 V terminals, providing a straightforward fixed-voltage transformer configuration.
Unlike multi-tap transformers with selectable secondary voltages, the XMS50P4S4 is specified with a single 110 V AC output connection. This makes it suitable for installations where the required control voltage is known and a compact, enclosed transformer is preferred.
Based on its 50 VA rating, the theoretical full-load secondary current is approximately 0.45 A at 110 V AC. This is calculated by dividing the rated apparent power by the nominal secondary voltage. Actual permissible loading, protective device selection and operating conditions must follow ETE's specifications and the requirements of the connected equipment.
The transformer's Class II construction provides a protective insulation arrangement, while its Class F insulation defines the winding insulation thermal classification. These are separate characteristics and should not be confused. The integral moulded housing and DIN rail or chassis mounting options support installation into suitable electrical assemblies. Correct primary and secondary connections, circuit protection, ventilation and mounting arrangements remain essential for safe operation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 50 VA | |
|---|---|---|
| Primary Voltage | 0/240V | |
| Secondary Voltage | 0/110V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | XMS Class II Enclosed Safety/Isolating Transformers | |
| Model | XMS50P4S4 | |
| Product type | Enclosed safety/isolating transformer | |
| Rated apparent power | 50 VA | |
| Number of phases | Single-phase | |
| Primary terminal arrangement | 0/240 V | |
| Primary voltage | 240 V AC | |
| Secondary terminal arrangement | 0/110 V | |
| Secondary voltage | 110 V AC | |
| Output connection | 110 V | |
| Protection class | Class II | |
| Insulation class | F | |
| Mounting | DIN rail or chassis | |
| Enclosure reference | Integral moulded housing | |
| Length | 90 mm | |
| Width | 106 mm | |
| Height | 87 mm | |
| Dimensions (L × W × H) | 90 × 106 × 87 mm | |
| Weight | 1.3 kg | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE XMS50P4S4 is a 50 VA single-phase Class II enclosed safety/isolating transformer designed to convert a 240 V AC supply into a 110 V AC output for compatible industrial control, signalling and automation applications.
The transformer has a 0/240 V primary terminal arrangement and is specified for a nominal 240 V AC input.
The transformer provides a nominal 110 V AC secondary output through its 0/110 V secondary terminals.
The transformer has a rated apparent power of 50 VA, making it suitable for appropriately rated 110 V AC control and signalling equipment.
Class II identifies a protective insulation construction based on double or reinforced insulation rather than reliance on a protective earth connection for basic electrical shock protection. The transformer must still be installed and connected according to ETE's instructions.
Based on the 50 VA rating and 110 V AC output, the theoretical full-load secondary current is approximately 0.45 A. Actual permissible loading must follow ETE's specifications.
Yes. The XMS50P4S4 is specified for DIN rail or chassis mounting, allowing it to be installed in compatible electrical control cabinets and equipment assemblies.
The transformer measures 90 mm long × 106 mm wide × 87 mm high and weighs 1.3 kg.
The transformer features Class F insulation and an integral moulded housing. Its protective construction is Class II, which is distinct from the Class F thermal insulation rating.
The ETE XMS50P4S4 combines a 50 VA rating, 240 V AC primary input, 110 V AC secondary output, Class II protective construction, Class F insulation and an integral moulded enclosure. With DIN rail or chassis mounting options, it offers a compact and flexible solution for industrial control panel builders, OEM equipment manufacturers and electrical maintenance engineers requiring an enclosed AC safety/isolating transformer.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.