ETE XMS200P5S6 Class II Enclosed Safety Transformer 200VA 0/415V to 0/24V

ETE XMS200P5S6 Class II Enclosed Safety Transformer 200VA 0/415V to 0/24V

ETE XMS200P5S6 is a 200 VA single-phase Class II enclosed safety/isolating transformer with a 415 V AC primary input, 24 V AC secondary output, Class F insulation and DIN rail or chassis mounting for industrial control applications.

SKU: XMS200P5S6MPN: XMS200P5S6
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ETE XMS200P5S6 Class II Safety/Isolating Transformer?

The ETE XMS200P5S6 is a high-quality 200 VA single-phase Class II enclosed safety/isolating transformer designed to provide reliable electrical isolation and a 24 V AC secondary supply for industrial control circuits, electrical panels and automation equipment. As part of the ETE XMS Class II transformer series, it combines double-insulated construction, protected terminals and flexible mounting options for dependable operation in industrial electrical installations.

Manufactured by Eastern Transformers & Equipment (ETE), this transformer features an integral flame-retardant moulded housing and IP20 touch-proof terminals. Its Class II construction provides protective insulation without requiring a protective earth connection. The transformer is designed to EN 61558-2-4 and EN 61558-2-6, with Class F insulation for reliable thermal performance.

With a rated capacity of 200 VA, a 415 V AC primary input and a 24 V AC secondary output, the XMS200P5S6 is suitable for supplying compatible low-voltage control equipment. Its compact enclosure, measuring 102 × 115.5 × 126 mm, supports convenient DIN rail or chassis mounting within electrical control panels and machinery installations.

Key Advantages

  • 200 VA single-phase transformer designed for industrial safety isolation and control circuit applications.
  • 415 V AC primary input and 24 V AC secondary output for low-voltage electrical equipment.
  • Class II double-insulated construction with no protective earth connection required.
  • Integral flame-retardant moulded housing meeting UL 94 V-0 material requirements.
  • IP20 touch-proof terminals help protect against accidental contact with live connections.
  • DIN rail or chassis mounting provides installation flexibility.
  • Class F insulation supports dependable transformer operation.
  • Designed to relevant EN 61558 transformer safety standards.

Key Features

  • ETE XMS Class II enclosed transformer series.
  • 200 VA rated apparent power.
  • Single-phase transformer configuration.
  • Primary terminals: 0/415 V AC.
  • Secondary terminals: 0/24 V AC.
  • 24 V AC output connection.
  • 50/60 Hz operating frequency.
  • Class II protective insulation without provision for protective earthing.
  • Class F insulation system.
  • IP20 touch-proof terminal protection.
  • Flame-retardant moulded enclosure to UL 94 V-0.
  • DIN rail or chassis mounting.
  • Designed for ambient temperatures from -10 to +35 °C.

Reliable Electrical Isolation and 24 V AC Control Power

Safety and isolating transformers provide electrical separation between primary and secondary circuits through transformer insulation. The ETE XMS200P5S6 converts a nominal 415 V AC single-phase supply into a 24 V AC output while maintaining electrical isolation between the windings. This makes it suitable for appropriately rated control circuits and electrical equipment requiring a separate low-voltage AC supply.

The XMS series uses Class II construction with an integral moulded enclosure, reducing the need for additional protective earthing arrangements for the transformer itself. Its IP20 touch-proof terminals and flexible DIN rail or chassis mounting make it practical for installation in industrial control cabinets, machinery panels and electrical distribution assemblies.

Typical Applications

  • Industrial electrical control panels requiring an isolated 24 V AC supply.
  • Machine control circuits and automation equipment.
  • 24 V AC contactor, relay and control device supplies within the transformer rating.
  • Electrical equipment requiring Class II transformer construction.
  • Industrial machinery and OEM control assemblies.
  • Building services and HVAC control circuits.
  • Low-voltage signalling and indication systems.
  • Electrical panel building and equipment manufacturing.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 200 VA
Primary Voltage 0/415V
Secondary Voltage 0/24V
Phase Single Phase
Manufacturer Eastern Transformers & Equipment (ETE)
Series XMS Class II Transformers
Model XMS200P5S6
Product type Enclosed safety/isolating transformer
Transformer configuration Single-phase
Rated apparent power 200 VA
Primary voltage 415 V AC
Primary terminals 0/415 V
Secondary voltage 24 V AC
Secondary terminals 0/24 V
Output connection 24 V AC
Rated frequency 50/60 Hz
Electrical protection class Class II
Insulation class F
Terminal protection rating IP20
Enclosure reference Integral moulded housing
Enclosure material characteristic Flame-retardant to UL 94 V-0
Mounting type DIN rail or chassis mounting
Length 102 mm
Width 115.5 mm
Height 126 mm
Dimensions (L × W × H) 102 × 115.5 × 126 mm
Weight 4 kg
Ambient operating temperature -10 to +35 °C
Applicable design standards EN 61558-2-4 / EN 61558-2-6
Protective earth connection Not provided (Class II)
Manufacturer range ETE stock control transformer range

Frequently Asked Questions

What is the ETE XMS200P5S6 used for?

The ETE XMS200P5S6 is a 200 VA Class II safety/isolating transformer used to provide an electrically isolated 24 V AC supply for compatible industrial control circuits, electrical panels and automation equipment.

What input and output voltages does this transformer have?

The transformer has a 415 V AC primary input with terminals marked 0/415 V and a 24 V AC secondary output with terminals marked 0/24 V.

What is the power rating of the XMS200P5S6?

The transformer has a rated apparent power of 200 VA, making it suitable for compatible 24 V AC loads within its rated capacity.

Does the ETE XMS200P5S6 require a protective earth connection?

No. The XMS200P5S6 uses Class II double-insulated construction and is manufactured without provision for a protective earth connection.

Can this transformer be mounted on a DIN rail?

Yes. The ETE XMS200P5S6 supports DIN rail or chassis mounting, allowing flexible installation within electrical control panels and equipment enclosures.

What are the dimensions and weight of this transformer?

The XMS200P5S6 measures 102 × 115.5 × 126 mm (L × W × H) and weighs approximately 4 kg.

What insulation and terminal protection does the transformer provide?

The transformer features Class F insulation, IP20 touch-proof terminals and an integral flame-retardant moulded housing to UL 94 V-0.

Trusted ETE Transformer Engineering

ETE XMS Class II transformers provide reliable electrical isolation, protected terminal connections and flexible installation for industrial control applications. The XMS200P5S6 combines a 200 VA rating, 415 V AC primary supply and 24 V AC secondary output in a robust, double-insulated enclosure designed for professional electrical installations.