ETE WV750P7S7 is a 750 VA single-phase wide-input-voltage control transformer with 0/380/400/420/440/460/480 V primary terminals, dual 0/24 V secondary windings configurable for 24 V parallel or 48 V series output, Class E insulation and 4% voltage regulation.
£105.30
The ETE WV750P7S7 is a robust 750 VA single-phase wide-input-voltage control transformer designed to provide dependable AC voltage transformation for industrial machinery, electrical control panels and automation systems. Part of the ETE WV stock control transformer range, it combines flexible primary voltage selection with dual secondary windings, making it a practical solution for industrial control panel builders, OEM machinery manufacturers and electrical maintenance engineers.
The WV750P7S7 features primary terminals marked 0/380/400/420/440/460/480 V, providing six nominal input voltage options for different industrial electrical supplies. Its dual 0/24 V secondary windings can be connected in parallel to provide a 24 V AC output or in series to provide a 48 V AC output. This configurable arrangement allows the same transformer to support different control voltage requirements while retaining a total rated capacity of 750 VA.
With Class E insulation and 4% voltage regulation, the ETE WV750P7S7 is suited to industrial applications requiring a substantial control transformer capacity and relatively stable secondary voltage performance. Measuring 150 × 108 × 145 mm and weighing 7.6 kg, it offers a practical combination of power capacity and manageable dimensions, with an associated EPN 3 enclosure reference.
The ETE WV750P7S7 transforms a selected industrial AC input voltage into a lower secondary voltage suitable for compatible control equipment. Its six nominal primary voltage connections support installations using 380 V, 400 V, 420 V, 440 V, 460 V or 480 V AC supplies. This flexibility can simplify transformer selection across machinery and electrical installations with different nominal supply voltages. The appropriate primary terminal must be selected to match the available supply.
On the secondary side, the transformer incorporates two separate 24 V AC windings. Connecting these windings correctly in parallel provides a 24 V AC output, while connecting them in series with additive polarity provides a 48 V AC output. Parallel operation requires matching winding polarity, and all connections must follow ETE's terminal identification and wiring instructions.
The transformer's 750 VA rating applies to its total apparent power capacity, rather than independently to each secondary winding. This capacity can support multiple compatible industrial control devices, provided their combined operating and starting demands remain within the manufacturer's permitted transformer and winding ratings. The specified 4% voltage regulation helps limit the variation in secondary voltage between no-load and rated-load conditions, although connected equipment must still be suitable for the expected voltage range.
With Class E insulation, a 7.6 kg weight and an associated EPN 3 enclosure reference, the WV750P7S7 is suitable for integration into appropriately designed industrial electrical equipment. Installation should account for adequate mechanical support, ventilation, protective devices, earthing and safe access to terminals.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 750 VA | |
|---|---|---|
| Primary Voltage | 0/380/400/420/440/460/480V | |
| Secondary Voltage | 0/24V + 0/24V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product range | WV Wide-Input-Voltage Stock Control Transformers | |
| Model / SKU | WV750P7S7 | |
| Product type | Wide-input-voltage industrial control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 750 VA | |
| Primary terminal markings | 0/380/400/420/440/460/480 V | |
| Nominal primary voltage options | 380/400/420/440/460/480 V AC | |
| Number of nominal primary voltage options | 6 | |
| Secondary terminal markings | 0/24 V + 0/24 V | |
| Secondary winding configuration | Dual 24 V AC windings | |
| Parallel output connection | 24 V AC | |
| Series output connection | 48 V AC | |
| Total transformer capacity | 750 VA | |
| Insulation class | E | |
| Voltage regulation | 4% | |
| Length | 150 mm | |
| Width | 108 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 108 × 145 mm | |
| Weight | 7.6 kg | |
| Enclosure reference | EPN 3 | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV750P7S7 is a 750 VA single-phase wide-input-voltage control transformer used to provide isolated 24 V or 48 V AC supplies for compatible industrial machinery, control panels and automation equipment.
The transformer has a total rated apparent power of 750 VA. This is the overall transformer rating and does not mean that each secondary winding can independently supply 750 VA.
Its primary terminals are marked 0/380/400/420/440/460/480 V, providing nominal input voltage options of 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC.
The transformer has dual 0/24 V secondary windings. They can be connected in parallel for 24 V AC or in series for 48 V AC, using the appropriate winding connections.
For 24 V AC, the two secondary windings are connected in parallel with matching polarity. For 48 V AC, they are connected in series with additive polarity. Connections must follow ETE's terminal identification and wiring instructions.
The transformer has Class E insulation, providing a defined thermal insulation classification for operation within the manufacturer's specified limits.
The ETE WV750P7S7 has 4% voltage regulation. This describes the specified variation in secondary voltage between no-load and rated-load conditions and should be considered when selecting connected control equipment.
The transformer measures 150 × 108 × 145 mm (length × width × height) and weighs 7.6 kg.
The specified enclosure reference is EPN 3. The installation should provide suitable mounting support, ventilation, electrical protection and access for wiring and maintenance.
Yes. Its 750 VA total rated capacity can support multiple compatible devices, provided their combined apparent power, starting demands and operating requirements remain within the transformer's overall and individual winding limits.
Yes. The transformer includes a nominal 400 V AC primary connection, alongside 380 V, 420 V, 440 V, 460 V and 480 V AC options. The correct primary terminal must be selected and wired according to the manufacturer's instructions.
The ETE WV750P7S7 combines 750 VA capacity, six nominal primary voltage options and configurable dual 24 V secondary windings in a robust industrial control transformer. With 24 V parallel or 48 V series output, Class E insulation and 4% voltage regulation, it provides a flexible solution for compatible industrial control and auxiliary AC power applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.