ETE WV50P7S8 is a 50 VA single-phase wide-input-voltage control transformer with selectable 380–480 V AC primary taps, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 15% voltage regulation.

SKU: WV50P7S8MPN: WV50P7S8
Price
List Price £34.30 ex VAT
Your Price (ex VAT) Save 25%
£25.73 25% OFF
You save £8.58 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £25.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£25.73

Why Choose the ETE WV50P7S8 50 VA Wide-Input-Voltage Control Transformer?

The ETE WV50P7S8 is a versatile 50 VA single-phase wide-input-voltage control transformer designed to provide reliable AC voltage conversion for industrial control panels, electrical machinery and automation systems. Part of the ETE WV wide-input-voltage transformer range, it features multiple primary voltage taps and dual secondary windings, making it suitable for equipment operating across different industrial supply voltages.

The WV50P7S8 features a 0/380/400/420/440/460/480 V primary terminal arrangement, allowing selection of the appropriate input connection for compatible AC supplies between 380 V and 480 V. Its two 0/110/120 V secondary windings can be connected in parallel to provide 110 V or 120 V AC, or in series to provide 220 V or 240 V AC, according to the required voltage configuration.

With a rated apparent power of 50 VA, Class E insulation and 15% voltage regulation, the WV50P7S8 is suited to appropriately rated industrial control applications. Its compact dimensions of 75 × 65 × 88 mm and weight of just 1 kg make it practical for installation in space-conscious control panels. Compatible enclosure references are EPH 1 or EPN 1.

Key Advantages

  • 50 VA rated capacity for compatible industrial control and automation circuits.
  • Wide primary voltage selection covering 380, 400, 420, 440, 460 and 480 V AC.
  • Dual secondary windings provide flexible series and parallel connection options.
  • 110 V or 120 V AC parallel output for compatible control equipment.
  • 220 V or 240 V AC series output for higher-voltage control circuits.
  • Class E insulation for dependable electrical insulation performance.
  • Compact 75 × 65 × 88 mm dimensions help conserve panel space.
  • Lightweight 1 kg construction simplifies handling and installation.
  • Provides electrical isolation between primary and secondary circuits.
  • EPH 1 or EPN 1 enclosure references offer protective housing options.

Key Features

  • ETE WV wide-input-voltage control transformer series.
  • 50 VA rated apparent power.
  • Single-phase transformer configuration.
  • Primary terminals: 0/380/400/420/440/460/480 V.
  • Selectable primary voltages: 380, 400, 420, 440, 460 and 480 V AC.
  • Secondary terminals: 0/110/120 V + 0/110/120 V.
  • Secondary configuration: Two configurable secondary windings.
  • Parallel secondary output: 110 V or 120 V AC.
  • Series secondary output: 220 V or 240 V AC.
  • Voltage regulation: 15%.
  • Insulation class: E.
  • Compact dimensions: 75 × 65 × 88 mm.
  • Weight: 1 kg.
  • Enclosure references: EPH 1 or EPN 1.

Flexible 380–480 V Input with 110/120 V or 220/240 V AC Output

The ETE WV50P7S8 is designed for industrial control applications where the available primary supply voltage may vary between installations. Its six selectable primary voltage taps allow the transformer to be configured for 380, 400, 420, 440, 460 or 480 V AC supplies, providing greater flexibility than a transformer with a single fixed primary voltage.

The transformer incorporates two secondary windings, each with 0/110/120 V terminals. By connecting matching secondary winding taps in parallel, a 110 V or 120 V AC output can be obtained. Connecting the windings in series allows a 220 V or 240 V AC output. Correct winding polarity and terminal selection are essential, and connections must follow the manufacturer's wiring instructions.

At its 50 VA rating, the theoretical full-load secondary current is approximately 0.45 A at 110 V, 0.42 A at 120 V, 0.23 A at 220 V or 0.21 A at 240 V, assuming the full transformer rating is available at the selected connection. Actual permissible loading must comply with ETE's winding and terminal ratings.

The specified 15% voltage regulation means secondary voltage variation under different load conditions should be considered when selecting connected equipment. Sensitive devices requiring tightly regulated supplies may need additional voltage regulation. Appropriate circuit protection, conductor sizing and enclosure selection should be provided for safe operation.

Typical Applications

  • Industrial electrical control panels and automation cabinets.
  • Control circuits supplied from 380–480 V AC industrial systems.
  • 110 V and 120 V AC relay and contactor control circuits.
  • 220 V and 240 V AC control circuits requiring a compatible isolated supply.
  • OEM machinery designed for multiple international supply voltages.
  • Industrial signalling and monitoring equipment.
  • Manufacturing machinery and production equipment.
  • Compact electrical control assemblies with limited installation space.
  • Replacement of compatible industrial control transformers.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 50 VA
Primary Voltage 0/380/400/420/440/460/480V
Secondary Voltage 0/110/120V + 0/110/120V
Phase Single Phase
Manufacturer ETE
Series WV Wide-Input-Voltage Control Transformers
Model WV50P7S8
Product type Wide-input-voltage control transformer
Rated apparent power 50 VA
Number of phases Single-phase
Primary terminal arrangement 0/380/400/420/440/460/480 V
Primary voltage options 380/400/420/440/460/480 V AC
Secondary terminal arrangement 0/110/120 V + 0/110/120 V
Secondary winding configuration Dual windings, series or parallel
Parallel secondary output 110/120 V AC
Series secondary output 220/240 V AC
Voltage regulation 15%
Insulation class E
Length 75 mm
Width 65 mm
Height 88 mm
Dimensions (L × W × H) 75 × 65 × 88 mm
Weight 1 kg
Enclosure reference EPH 1 or EPN 1
Product range reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE WV50P7S8 used for?

The ETE WV50P7S8 is a 50 VA single-phase wide-input-voltage control transformer designed to convert compatible 380–480 V AC supplies into selectable 110/120 V or 220/240 V AC outputs for industrial control equipment.

What primary voltages does the WV50P7S8 support?

The transformer has a 0/380/400/420/440/460/480 V primary terminal arrangement, allowing selection of 380, 400, 420, 440, 460 or 480 V AC using the appropriate input terminals.

What secondary voltages can the ETE WV50P7S8 provide?

The transformer provides 110 V or 120 V AC with its two secondary windings connected in parallel, or 220 V or 240 V AC when the windings are connected in series.

What is the power rating of the WV50P7S8?

The transformer has a rated apparent power of 50 VA, suitable for appropriately rated industrial control and automation circuits.

How are the secondary windings connected in series or parallel?

The two 0/110/120 V secondary windings can be connected in parallel for 110/120 V AC or in series for 220/240 V AC. Correct winding polarity and terminal connections must be verified against ETE's wiring instructions before energising the transformer.

What does 15% voltage regulation mean?

The specified 15% voltage regulation indicates that the secondary voltage can vary with load. Connected equipment should be suitable for the resulting voltage range, and additional regulation may be necessary for voltage-sensitive applications.

What are the dimensions and weight of the WV50P7S8?

The transformer measures 75 mm long × 65 mm wide × 88 mm high and weighs 1 kg.

What insulation class does the WV50P7S8 have?

The transformer features Class E insulation, as specified in the ETE stock control transformer range.

Which enclosure is specified for the ETE WV50P7S8?

The specified enclosure references are EPH 1 or EPN 1. The appropriate enclosure should be selected according to the installation and required environmental protection.

A Practical Choice for Industrial Control Panel Builders

The ETE WV50P7S8 combines a 50 VA rating, six selectable primary voltage taps, configurable 110/120 V and 220/240 V secondary outputs, Class E insulation and compact dimensions. Its wide-input-voltage design makes it a practical solution for industrial control panel manufacturers, OEM machinery builders and electrical maintenance engineers requiring flexible AC control voltage conversion.