Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE WV500P8S8 is a 500 VA single-phase wide-input-voltage control transformer with selectable 500/550/600/690 V AC primary taps, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 8% voltage regulation.
£72.23
The ETE WV500P8S8 is a versatile 500 VA single-phase wide-input-voltage control transformer designed for industrial electrical control panels, machinery, switchgear and automation systems. Part of the ETE WV wide-input-voltage control transformer range, it combines multiple high-voltage primary taps with configurable dual secondary windings, providing flexible AC voltage conversion for industrial installations operating with different supply voltages.
The WV500P8S8 features a 0/500/550/600/690 V primary terminal arrangement, supporting compatible 500, 550, 600 and 690 V AC supplies. Its two 0/110/120 V secondary windings can be connected in parallel for 110 V or 120 V AC, or in series for 220 V or 240 V AC. This flexibility makes the transformer suitable for industrial control equipment with different operating voltage requirements.
With a rated apparent power of 500 VA, Class E insulation and 8% voltage regulation, the WV500P8S8 provides a practical solution for appropriately rated industrial control circuits. Its dimensions of 120 × 120 × 120 mm and weight of 6.2 kg make it suitable for installation in electrical control cabinets with appropriate mounting arrangements. The specified enclosure references are EPH 3 or EPN 2.
The ETE WV500P8S8 is designed for industrial control installations where the available primary supply voltage may differ between machines, facilities or electrical systems. Its selectable primary terminals support 500, 550, 600 and 690 V AC, allowing the transformer to be configured for several compatible industrial electrical supplies.
The transformer incorporates two secondary windings, each with 0/110/120 V terminals. Connecting matching secondary winding taps in parallel with the correct polarity provides 110 V or 120 V AC. Connecting the windings in series with the correct additive polarity provides 220 V or 240 V AC. All winding connections must follow ETE's instructions to ensure correct voltage selection and safe operation.
Based on its 500 VA rating, the theoretical full-load secondary current is approximately 4.55 A at 110 V AC, 4.17 A at 120 V AC, 2.27 A at 220 V AC or 2.08 A at 240 V AC. These calculated values assume the full rated apparent power is available in the selected configuration. Actual permissible winding currents and loading requirements must follow ETE's specifications.
The specified 8% voltage regulation means secondary voltage variation between operating load conditions should be considered when selecting connected equipment. Sensitive devices requiring tightly regulated supplies may need additional voltage regulation. Correct primary tap selection, secondary winding polarity, suitable circuit protection, conductor sizing and appropriate installation clearances are particularly important when working with primary supplies up to 690 V AC.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 500 VA | |
|---|---|---|
| Primary Voltage | 0/500/550/600/690V | |
| Secondary Voltage | 0/110/120V + 0/110/120V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | WV Wide-Input-Voltage Control Transformers | |
| Model | WV500P8S8 | |
| Product type | Wide-input-voltage control transformer | |
| Rated apparent power | 500 VA | |
| Number of phases | Single-phase | |
| Primary terminal arrangement | 0/500/550/600/690 V | |
| Primary voltage options | 500/550/600/690 V AC | |
| Secondary terminal arrangement | 0/110/120 V + 0/110/120 V | |
| Secondary winding configuration | Dual windings, series or parallel | |
| Parallel secondary output | 110/120 V AC | |
| Series secondary output | 220/240 V AC | |
| Voltage regulation | 8% | |
| Insulation class | E | |
| Length | 120 mm | |
| Width | 120 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 120 × 120 mm | |
| Weight | 6.2 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV500P8S8 is a 500 VA single-phase wide-input-voltage control transformer designed to convert compatible 500–690 V AC supplies into selectable 110/120 V or 220/240 V AC outputs for industrial control circuits, machinery and automation equipment.
The transformer features a 0/500/550/600/690 V primary terminal arrangement, supporting selectable 500, 550, 600 and 690 V AC input connections.
The transformer provides 110 V or 120 V AC when its secondary windings are connected in parallel, or 220 V or 240 V AC when they are connected in series.
The transformer has a rated apparent power of 500 VA, making it suitable for appropriately rated industrial control, signalling and automation applications.
The two 0/110/120 V secondary windings must be connected according to ETE's wiring instructions. Parallel operation requires matching winding voltages and correct polarity, while series operation requires the correct additive-polarity connection to obtain 220 V or 240 V AC.
Based on the 500 VA rating, the theoretical full-load secondary current is approximately 4.55 A at 110 V AC, 4.17 A at 120 V AC, 2.27 A at 220 V AC or 2.08 A at 240 V AC, assuming the full rating is available in the selected configuration. Actual permissible loading must follow ETE's specifications.
The specified 8% voltage regulation describes the transformer's secondary voltage variation between load conditions. Connected equipment should tolerate the resulting voltage variation, and additional regulation may be required for voltage-sensitive devices.
The transformer measures 120 mm long × 120 mm wide × 120 mm high and weighs 6.2 kg, making it suitable for appropriately sized industrial control cabinets.
The transformer features Class E insulation and specifies EPH 3 or EPN 2 as its enclosure references. The appropriate enclosure should be selected according to installation requirements.
The ETE WV500P8S8 combines a 500 VA rating, four selectable high-voltage primary taps, configurable 110/120 V and 220/240 V AC secondary outputs, Class E insulation and 8% voltage regulation. Its wide-input-voltage design makes it a practical choice for industrial control panel builders, OEM machinery manufacturers and electrical maintenance engineers requiring flexible AC control voltage conversion.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.