ETE WV3000P8S8 is a 3000 VA single-phase wide-input-voltage control transformer with 0/500/550/600/690 V primary terminals, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 3% voltage regulation.
£330.45
The ETE WV3000P8S8 is a high-capacity 3000 VA (3 kVA) single-phase wide-input-voltage control transformer designed to provide reliable AC voltage transformation and electrical isolation for industrial machinery, electrical control panels and automation systems. Part of the ETE WV stock control transformer range, it combines multiple high-voltage primary connections with configurable secondary windings, making it a practical solution for industrial control panel builders, OEM machinery manufacturers and electrical maintenance engineers.
The WV3000P8S8 features primary terminals marked 0/500/550/600/690 V, providing four nominal input voltage options for industrial electrical installations. Its dual 0/110/120 V secondary windings can be connected in parallel to provide 110 V or 120 V AC, or in series to provide 220 V or 240 V AC. This flexible arrangement enables the same transformer model to accommodate several industrial control voltage requirements while delivering a total rated apparent power of 3000 VA.
With Class E insulation and 3% voltage regulation, the ETE WV3000P8S8 offers substantial control power capacity, high-voltage input flexibility and relatively low specified voltage regulation. Measuring 192 × 189 × 185 mm and weighing 28 kg, it is intended for integration into appropriately engineered industrial electrical installations, with an associated EPN 5 enclosure reference. Its combination of 500–690 V primary connections and configurable secondary voltages makes it particularly relevant to machinery and control systems operating from higher-voltage industrial supplies.
The ETE WV3000P8S8 transforms a selected higher-voltage industrial AC input into a secondary supply suitable for compatible control equipment. Its four nominal primary voltage connections support installations using 500 V, 550 V, 600 V or 690 V AC supplies. This flexibility can simplify transformer selection across machinery and electrical installations with different nominal supply voltages. The correct primary terminal must be selected to match the available supply and connected in accordance with ETE's instructions.
On the secondary side, the transformer incorporates two separate windings, each marked 0/110/120 V. When correctly connected in parallel, corresponding winding taps provide 110 V or 120 V AC. When connected in series with additive polarity, they provide 220 V or 240 V AC. Parallel connections require matching voltage taps and winding polarity, while series connections must use the correct additive polarity arrangement. Incorrect connections can cause damaging circulating currents or an unsuitable output voltage, so the manufacturer's terminal identification and wiring instructions must be followed before energising the transformer.
The 3000 VA (3 kVA) rating represents the transformer's total rated apparent power, rather than a separate 3000 VA allowance for each secondary winding. This capacity makes the WV3000P8S8 relevant to industrial control systems with substantial combined AC power demands, provided connected equipment remains within the transformer's permitted continuous and starting-load ratings. Its specified 3% voltage regulation should also be considered when selecting voltage-sensitive control equipment, as the secondary voltage can vary with loading.
With Class E insulation, a 28 kg weight and an associated EPN 5 enclosure reference, the WV3000P8S8 is intended for integration into appropriately engineered industrial electrical installations. Suitable mechanical support is essential for a transformer of this weight. Because the primary connections include voltages up to 690 V AC, installation design must provide appropriate insulation clearances, circuit protection, earthing, conductor sizing, ventilation and safe access for inspection and maintenance. The required terminal connections and individual winding limits should be confirmed against ETE's installation documentation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 3000 VA | |
|---|---|---|
| Primary Voltage | 0/500/550/600/690V | |
| Secondary Voltage | 0/110/120V + 0/110/120V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product range | WV Wide-Input-Voltage Stock Control Transformers | |
| Model / SKU | WV3000P8S8 | |
| Product type | Wide-input-voltage industrial control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 3000 VA (3 kVA) | |
| Primary terminals | 0/500/550/600/690 V | |
| Nominal primary voltage options | 500 V, 550 V, 600 V and 690 V AC | |
| Number of nominal primary voltage options | 4 | |
| Secondary terminals | 0/110/120 V + 0/110/120 V | |
| Secondary winding configuration | Two tapped 110/120 V AC windings | |
| Parallel output connection | 110 V or 120 V AC | |
| Series output connection | 220 V or 240 V AC | |
| Total transformer capacity | 3000 VA | |
| Insulation class | E | |
| Voltage regulation | 3% | |
| Length | 192 mm | |
| Width | 189 mm | |
| Height | 185 mm | |
| Dimensions (L × W × H) | 192 × 189 × 185 mm | |
| Weight | 28 kg | |
| Enclosure reference | EPN 5 | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV3000P8S8 is a 3000 VA single-phase wide-input-voltage control transformer used to provide isolated 110 V, 120 V, 220 V or 240 V AC supplies for compatible industrial machinery, electrical control panels and automation equipment.
The transformer has a total rated apparent power of 3000 VA (3 kVA). This is the overall transformer capacity and does not mean that each secondary winding can independently supply 3000 VA.
Its primary terminals are marked 0/500/550/600/690 V, providing nominal input voltage options of 500 V, 550 V, 600 V and 690 V AC.
The transformer has dual 0/110/120 V secondary windings. They can be connected in parallel for 110 V or 120 V AC, or in series for 220 V or 240 V AC, using the appropriate winding connections.
For 110 V or 120 V AC, the corresponding secondary winding taps are connected in parallel with matching polarity. For 220 V or 240 V AC, the corresponding windings are connected in series with additive polarity. All wiring must follow ETE's terminal identification and connection instructions.
Yes. The transformer includes a nominal 690 V AC primary connection, alongside 500 V, 550 V and 600 V AC options. The correct primary terminal must be selected and the installation must be designed for the applicable supply voltage and electrical protection requirements.
The transformer has Class E insulation, providing a defined thermal insulation classification for operation within the manufacturer's specified limits.
The ETE WV3000P8S8 has 3% voltage regulation. This is the specified regulation characteristic and should be considered when selecting connected equipment because secondary voltage can vary between no-load and rated-load conditions.
The transformer measures 192 × 189 × 185 mm (length × width × height) and weighs 28 kg. Its installation must provide suitable mechanical support.
The specified enclosure reference is EPN 5. Enclosure selection and installation should account for suitable mounting support, ventilation, electrical protection and access for wiring and maintenance.
Yes. Its 3000 VA total rated capacity can support multiple compatible devices, provided their combined apparent power, starting demands and operating requirements remain within the transformer's overall and individual winding limits.
The ETE WV3000P8S8 combines 3000 VA (3 kVA) capacity, four nominal primary voltage options from 500 V to 690 V AC and configurable dual 110/120 V secondary windings in a high-capacity industrial control transformer. With 110/120 V parallel or 220/240 V series output, Class E insulation and 3% voltage regulation, it provides a flexible solution for compatible industrial control and auxiliary AC power applications.