ETE WV250P7S7 is a 250 VA single-phase wide-input-voltage control transformer with selectable 380-480 V AC primary taps, dual 24 V AC secondary windings configurable for 24 V parallel or 48 V series output, Class E insulation and 8% voltage regulation.
£53.70
The ETE WV250P7S7 is a versatile 250 VA single-phase wide-input-voltage control transformer designed to provide reliable electrical isolation and flexible low-voltage AC power for industrial control panels, machinery and automation equipment. Part of the ETE WV Wide Input Voltage transformer series, it features multiple primary voltage taps covering 380–480 V AC and two separate 24 V AC secondary windings that can be connected in parallel for 24 V AC or in series for 48 V AC.
Manufactured by Eastern Transformers & Equipment (ETE), the WV250P7S7 provides an adaptable solution for electrical installations operating at different industrial supply voltages. Its wide selection of primary connections allows panel builders and equipment manufacturers to accommodate compatible 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC supplies without changing transformer models.
With a rated capacity of 250 VA, Class E insulation and 8% voltage regulation, the WV250P7S7 combines practical electrical performance with flexible secondary connection options. Measuring 120 × 88 × 120 mm and weighing 3.9 kg, it is suitable for integration into industrial electrical equipment, with EPH 3 or EPN 2 specified as compatible enclosure references.
The ETE WV250P7S7 is designed for installations where different industrial supply voltages may be encountered. Its primary winding includes terminals marked 0/380/400/420/440/460/480 V, allowing the appropriate primary connection to be selected for the available nominal supply.
This arrangement makes the transformer particularly useful for OEM machinery manufacturers, industrial panel builders and equipment suppliers working with electrical systems that use different nominal voltages. By selecting the correct primary terminals, the transformer can be configured for compatible supplies without requiring a separate transformer model for each voltage.
The primary voltage taps are discrete connections rather than an automatic voltage-ranging system. The installer must select the correct terminals to match the supply and follow the manufacturer's wiring instructions before energising the transformer.
One of the principal advantages of the WV250P7S7 is its dual-secondary winding arrangement. The transformer features two separate secondary windings, each with terminals marked 0/24 V, allowing the outputs to be configured for different control voltage requirements.
The 250 VA rating applies to the transformer as a whole and must not be interpreted as 250 VA available independently from each secondary winding. Winding polarity, current sharing, suitable protection and the permitted loading arrangement should be verified against ETE's connection instructions before installation.
These selectable outputs make the WV250P7S7 a practical choice for electrical control panels that may require either 24 V AC or 48 V AC control power, depending on the connected equipment.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 250 VA | |
|---|---|---|
| Primary Voltage | 0/380/400/420/440/460/480V | |
| Secondary Voltage | 0/24V + 0/24V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | WV Wide Input Voltage Transformers | |
| Model | WV250P7S7 | |
| Product type | Wide-input-voltage control transformer | |
| Transformer configuration | Single-phase | |
| Rated apparent power | 250 VA | |
| Primary terminals | 0/380/400/420/440/460/480 V | |
| Primary voltage options | 380, 400, 420, 440, 460 or 480 V AC | |
| Primary voltage range | 380–480 V AC using the appropriate voltage tap | |
| Secondary terminals | 0/24 V + 0/24 V | |
| Secondary winding arrangement | Two 24 V AC windings | |
| Parallel secondary connection | 24 V AC | |
| Series secondary connection | 48 V AC | |
| Output connection | 24 V parallel or 48 V series | |
| Voltage regulation | 8% | |
| Insulation class | E | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Length | 120 mm | |
| Width | 88 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 88 × 120 mm | |
| Weight | 3.9 kg | |
| Manufacturer range | ETE stock control transformer range | |
| Specification reference | ETE stock control transformer price list, March 2026 |
The ETE WV250P7S7 is a 250 VA single-phase wide-input-voltage control transformer used to provide isolated 24 V AC or 48 V AC power for compatible industrial control circuits, machinery and automation equipment.
The transformer has primary terminals marked 0/380/400/420/440/460/480 V, allowing connection to nominal 380, 400, 420, 440, 460 or 480 V AC supplies using the appropriate voltage tap.
The WV250P7S7 has two separate 24 V AC secondary windings, with terminals marked 0/24 V + 0/24 V. These can be connected in parallel for 24 V AC or in series for 48 V AC.
For 24 V AC output, the two secondary windings are connected in parallel with the correct winding polarity. The manufacturer's connection instructions must be followed to ensure correct phasing and current sharing.
For 48 V AC output, the two 24 V AC secondary windings are connected in series with the correct polarity. The exact terminal connections should be verified against ETE's wiring instructions.
The transformer has a rated apparent power of 250 VA. This is the total transformer rating, not a separate 250 VA rating for each secondary winding.
The WV250P7S7 has a specified 8% voltage regulation, describing the secondary voltage variation between the manufacturer's defined load conditions.
The transformer measures 120 × 88 × 120 mm (L × W × H) and weighs 3.9 kg, making it suitable for integration into appropriately designed industrial electrical panels.
The transformer features Class E insulation. The manufacturer's specified enclosure references are EPH 3 or EPN 2, which can be used when selecting a suitable protective enclosure.
ETE WV wide-input-voltage transformers provide adaptable primary supply connections, dependable electrical isolation and flexible secondary winding configurations for industrial control applications. The WV250P7S7 combines a 250 VA rating, six primary voltage taps from 380–480 V AC and selectable 24 V AC or 48 V AC secondary connections with Class E insulation and 8% voltage regulation, making it a practical solution for professional electrical panel builders and industrial equipment manufacturers.