ETE WV200P8S8 Wide Input Voltage Control Transformer 200VA 0/500/550/600/690V to 0/110/120V + 0/110/120V

ETE WV200P8S8 Wide Input Voltage Control Transformer 200VA 0/500/550/600/690V to 0/110/120V + 0/110/120V

ETE WV200P8S8 is a 200 VA single-phase wide-input-voltage control transformer with 500/550/600/690 V AC primary taps, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 10% voltage regulation.

SKU: WV200P8S8MPN: WV200P8S8
Price
List Price £60.60 ex VAT
Your Price (ex VAT) Save 25%
£45.45 25% OFF
You save £15.15 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £45.45
Trade pricing is personalised to your account

Manufacturer Lead Time

£45.45

Why Choose the ETE WV200P8S8 200 VA Wide-Input-Voltage Control Transformer?

The ETE WV200P8S8 is a 200 VA single-phase wide-input-voltage control transformer designed for industrial electrical installations requiring higher primary supply voltages and flexible secondary output configurations. Part of the ETE WV wide-input-voltage transformer series, it features 0/500/550/600/690 V primary terminals and two secondary winding groups marked 0/110/120 V + 0/110/120 V.

The WV200P8S8 supports 110 V AC or 120 V AC output with the secondary windings connected in parallel, or 220 V AC or 240 V AC output with the secondary windings connected in series. This versatility makes it suitable for industrial control panels, OEM machinery and automation equipment requiring different AC control voltages from compatible higher-voltage electrical supplies.

Its multi-tapped primary winding provides nominal input selections of 500 V, 550 V, 600 V and 690 V AC, allowing the appropriate terminal to be selected for the installation. The dual secondary winding arrangement offers additional flexibility, enabling electrical engineers to configure the output voltage to suit compatible control equipment without requiring a different transformer model for each supported secondary voltage.

With Class E insulation, 10% voltage regulation, dimensions of 96 × 87 × 103 mm and a weight of 2.8 kg, the ETE WV200P8S8 provides a compact and adaptable industrial control power solution. Its associated enclosure references are EPH 2 or EPN 1, supporting enclosure selection during electrical panel design.

Key Advantages

  • 200 VA rated capacity: Provides dedicated AC power for compatible industrial control circuits and automation equipment.
  • High-voltage primary selection: Supports nominal 500 V, 550 V, 600 V and 690 V AC primary connections.
  • Dual secondary windings: Features two 0/110/120 V winding groups for flexible output arrangements.
  • 110 V AC parallel output: Suitable for compatible 110 V industrial control equipment.
  • 120 V AC parallel output: Supports equipment requiring a nominal 120 V AC control supply.
  • 220 V AC series output: Provides an alternative voltage configuration for compatible 220 V AC loads.
  • 240 V AC series output: Supports compatible 240 V AC control applications.
  • Flexible transformer selection: Multiple primary and secondary configurations help accommodate different machinery supply and control voltage requirements.
  • Class E insulation: Provides a defined thermal insulation classification.
  • 10% voltage regulation: Provides a specified indication of secondary voltage variation under changing load conditions.
  • Compact dimensions: The 96 × 87 × 103 mm format assists with electrical panel layout planning.
  • 2.8 kg weight: Allows suitable mechanical support and mounting arrangements to be specified.
  • Enclosure references: EPH 2 or EPN 1 options are identified for installation planning.
  • Single-phase construction: Suitable for dedicated AC control voltage transformation.

Key Features

  • ETE WV wide-input-voltage control transformer series.
  • 200 VA rated apparent power.
  • 0.2 kVA transformer capacity.
  • Single-phase transformer configuration.
  • Primary terminal arrangement: 0/500/550/600/690 V.
  • Selectable nominal primary voltages: 500 V, 550 V, 600 V and 690 V AC.
  • Secondary winding 1: 0/110/120 V.
  • Secondary winding 2: 0/110/120 V.
  • Parallel secondary configuration: 110 V or 120 V AC.
  • Series secondary configuration: 220 V or 240 V AC.
  • Winding connection flexibility: Supports series or parallel connection of the two secondary windings.
  • Insulation class: E.
  • Voltage regulation: 10%.
  • Length: 96 mm.
  • Width: 87 mm.
  • Height: 103 mm.
  • Weight: 2.8 kg.
  • Associated enclosure references: EPH 2 or EPN 1.
  • Suitable for appropriately designed industrial electrical installations requiring a compatible 500–690 V AC primary supply and selectable secondary control voltages.

Flexible Industrial Control Power for 500–690 V AC Supply Systems

The ETE WV200P8S8 provides a practical solution for industrial installations operating with higher primary supply voltages while requiring lower AC control voltages. Its primary terminals support nominal selections of 500 V, 550 V, 600 V and 690 V AC, allowing the transformer to be configured for compatible industrial electrical systems. The correct primary terminal must be selected to match the actual supply voltage and the manufacturer's connection instructions.

A key advantage is its two separate 0/110/120 V secondary windings. When connected correctly in parallel, the windings provide a nominal 110 V AC or 120 V AC output. Parallel operation allows the current contribution of both windings to be combined, subject to the transformer's overall 200 VA rating. Matching voltage taps and correct winding polarity are essential because incorrect parallel connections can produce damaging circulating currents.

When connected correctly in series, the secondary windings provide a nominal 220 V AC or 240 V AC output. This configuration combines the voltages of the two windings while retaining the transformer's overall apparent power rating. Correct winding polarity and terminal identification are important because incorrect series connections can result in voltage cancellation or an unsuitable output voltage.

At the rated 200 VA capacity, the calculated nominal secondary currents are approximately 1.82 A at 110 V, 1.67 A at 120 V, 0.91 A at 220 V and 0.83 A at 240 V. These figures are calculated from the transformer's apparent power rating and nominal output voltages rather than separately verified manufacturer current ratings. The 200 VA rating applies to the transformer as a whole and must not be interpreted as 200 VA independently available from each secondary winding.

The specified 10% voltage regulation is relevant when evaluating secondary voltage variation under changing load conditions. Actual output voltage depends on the selected primary tap, supply voltage, winding configuration and connected load. Equipment with narrow operating voltage tolerances should therefore be checked for compatibility, particularly where control relays, contactor coils or other inductive devices introduce changing loads.

With Class E insulation, compact dimensions and associated EPH 2 or EPN 1 enclosure references, the WV200P8S8 can be incorporated into appropriately engineered electrical control assemblies. Suitable primary and secondary circuit protection, conductor sizing, mounting, ventilation and electrical clearances must be provided. Because the primary connections include voltages up to 690 V AC, installation and maintenance must be carried out by suitably qualified personnel using equipment and protective arrangements appropriate to the supply voltage.

Typical Applications

  • Industrial control panels supplied from compatible 500 V AC systems.
  • Industrial machinery operating with 550 V AC primary supplies.
  • Industrial electrical equipment using 600 V AC supply arrangements.
  • 690 V AC industrial machinery requiring lower-voltage AC control power.
  • Control circuits requiring selectable 110 V or 120 V AC outputs.
  • Control circuits requiring selectable 220 V or 240 V AC outputs.
  • OEM machinery and industrial automation equipment.
  • Motor control panels requiring dedicated AC control power.
  • Control relays and contactors with compatible AC coil voltages.
  • Industrial signalling and indication circuits.
  • Electrical panel building and system integration.
  • Industrial process control equipment with suitable AC loads.
  • Control transformer replacement and maintenance projects.
  • Equipment requiring series-connected or parallel-connected transformer secondary windings.
  • Control circuit upgrades requiring a 200 VA high-voltage-primary control transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 200 VA
Primary Voltage 0/500/550/600/690V
Secondary Voltage 0/110/120V + 0/110/120V
Phase Single Phase
Manufacturer ETE
Product series WV Wide-Input-Voltage Control Transformers
Manufacturer part number WV200P8S8
Product type Wide-input-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 200 VA
Rated capacity 0.2 kVA
Primary terminals 0/500/550/600/690 V
Nominal primary voltage options 500 V, 550 V, 600 V or 690 V AC
Number of secondary windings 2
Secondary winding 1 terminals 0/110/120 V
Secondary winding 2 terminals 0/110/120 V
Parallel output option 1 110 V AC
Parallel output option 2 120 V AC
Series output option 1 220 V AC
Series output option 2 240 V AC
Secondary connection arrangement 110/120 V parallel or 220/240 V series
Calculated secondary current at 110 V parallel Approximately 1.82 A at 200 VA
Calculated secondary current at 120 V parallel Approximately 1.67 A at 200 VA
Calculated secondary current at 220 V series Approximately 0.91 A at 200 VA
Calculated secondary current at 240 V series Approximately 0.83 A at 200 VA
Insulation class E
Voltage regulation 10%
Length 96 mm
Width 87 mm
Height 103 mm
Dimensions (L × W × H) 96 × 87 × 103 mm
Weight 2.8 kg
Enclosure reference EPH 2 or EPN 1
Product range ETE Stock Control Transformers
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE WV200P8S8 used for?

The ETE WV200P8S8 is a 200 VA single-phase wide-input-voltage control transformer used to provide selectable 110 V, 120 V, 220 V or 240 V AC outputs for compatible industrial control circuits and machinery supplied from appropriate higher-voltage primary connections.

What is the power rating of the ETE WV200P8S8?

The transformer has a rated apparent power of 200 VA (0.2 kVA). This is the overall transformer rating and applies to the combined load on its secondary windings.

What primary voltages does the WV200P8S8 support?

The transformer features 0/500/550/600/690 V primary terminals, supporting nominal primary voltage selections of 500 V, 550 V, 600 V or 690 V AC using the appropriate terminal connection.

What secondary voltages can the WV200P8S8 provide?

The transformer supports 110 V or 120 V AC with the secondary windings connected in parallel, and 220 V or 240 V AC with the secondary windings connected in series, using the manufacturer's specified wiring arrangements.

How many secondary windings does the WV200P8S8 have?

The WV200P8S8 has two secondary windings, each with 0/110/120 V terminals. The windings can be connected in the specified series or parallel configurations.

Can the WV200P8S8 provide 110 V or 120 V AC in parallel?

Yes. The two secondary windings can be connected in parallel to provide a nominal 110 V AC or 120 V AC output. Matching taps and correct winding polarity are essential, and the combined load must remain within the 200 VA rating.

Can the WV200P8S8 provide 220 V or 240 V AC in series?

Yes. The two secondary windings can be connected in series to provide a nominal 220 V AC or 240 V AC output. The correct series connection and winding polarity must be followed according to the manufacturer's instructions.

What is the calculated secondary current at 110 V?

At the rated 200 VA capacity and a nominal 110 V AC parallel output, the calculated current is approximately 1.82 A. This is a calculated value rather than a separately verified manufacturer current rating.

What is the calculated secondary current at 120 V?

At the rated 200 VA capacity and a nominal 120 V AC parallel output, the calculated current is approximately 1.67 A. This is a calculated value rather than a separately verified manufacturer current rating.

What is the calculated secondary current at 220 V or 240 V?

At the rated 200 VA capacity, the calculated current is approximately 0.91 A at 220 V AC or 0.83 A at 240 V AC with the secondary windings correctly connected in series. These are calculated values rather than separately verified manufacturer current ratings.

What does the 10% voltage regulation specification mean?

The WV200P8S8 has a specified 10% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should have suitable operating voltage tolerance.

What insulation class does the ETE WV200P8S8 use?

The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.

What are the dimensions and weight of the ETE WV200P8S8?

The transformer measures 96 × 87 × 103 mm (L × W × H) and weighs 2.8 kg. These details assist with electrical panel layout and mounting arrangements.

Which enclosure references are associated with the WV200P8S8?

The associated enclosure references are EPH 2 or EPN 1. The appropriate enclosure and its suitability for the installation should be confirmed before selection.

What should be checked before installing the ETE WV200P8S8?

Before installation, select the correct primary terminal for the supply voltage, confirm the required secondary voltage and follow the manufacturer's series or parallel wiring instructions. Check the combined connected load against the 200 VA rating and provide suitable circuit protection, conductor sizing, mounting, ventilation and electrical clearances appropriate to the installation voltage.

Trusted by Industrial Panel Builders and Automation Engineers

ETE WV wide-input-voltage control transformers provide a flexible solution for industrial electrical applications requiring higher primary voltage selections and configurable secondary outputs. With 500/550/600/690 V primary voltage options, dual 0/110/120 V secondary windings, series or parallel output connections, a 200 VA rating and Class E insulation, the WV200P8S8 offers electrical panel builders, machinery manufacturers and automation engineers a practical transformer option for industrial control power.