ETE WV200P7S8 Wide Input Voltage Control Transformer 200VA 0/380/400/420/440/460/480V to 0/110/120V + 0/110/120V

ETE WV200P7S8 Wide Input Voltage Control Transformer 200VA 0/380/400/420/440/460/480V to 0/110/120V + 0/110/120V

ETE WV200P7S8 is a 200 VA single-phase wide-input-voltage control transformer with 380-480 V AC primary taps, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 10% voltage regulation.

SKU: WV200P7S8MPN: WV200P7S8
Price
List Price £60.60 ex VAT
Your Price (ex VAT) Save 25%
£45.45 25% OFF
You save £15.15 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £45.45
Trade pricing is personalised to your account

Manufacturer Lead Time

£45.45

Why Choose the ETE WV200P7S8 200 VA Wide-Input-Voltage Control Transformer?

The ETE WV200P7S8 is a 200 VA single-phase wide-input-voltage control transformer designed for industrial electrical installations requiring multiple primary voltage selections and flexible secondary output configurations. Part of the ETE WV wide-input-voltage transformer series, it features 0/380/400/420/440/460/480 V primary terminals and two independent secondary winding terminal groups marked 0/110/120 V + 0/110/120 V.

The WV200P7S8 supports 110 V AC or 120 V AC output with the secondary windings connected in parallel, or 220 V AC or 240 V AC output with the secondary windings connected in series. This versatility makes it suitable for industrial control panels, OEM machinery and automation equipment requiring different AC control voltages without changing transformer models.

Its multi-tapped primary winding accommodates nominal supply selections from 380 V to 480 V AC through the appropriate primary terminals. The dual secondary winding arrangement offers further flexibility, allowing engineers to select the output voltage and winding configuration required by the connected control equipment.

With Class E insulation, 10% voltage regulation, dimensions of 96 × 87 × 103 mm and a weight of 2.8 kg, the ETE WV200P7S8 provides a compact and adaptable industrial control power solution. Associated enclosure references are EPH 2 or EPN 1, supporting enclosure selection during electrical panel design.

Key Advantages

  • 200 VA rated capacity: Provides dedicated AC power for compatible industrial control circuits and automation equipment.
  • Wide primary voltage selection: Supports nominal 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC supply connections.
  • Dual secondary windings: Features two 0/110/120 V winding groups for flexible output arrangements.
  • 110 V AC parallel output: Suitable for compatible 110 V industrial control equipment.
  • 120 V AC parallel output: Supports equipment requiring a nominal 120 V AC control supply.
  • 220 V AC series output: Provides an alternative voltage configuration for compatible 220 V AC loads.
  • 240 V AC series output: Supports compatible 240 V AC control applications.
  • Flexible transformer selection: Multiple primary and secondary configurations help accommodate different machinery supply and control voltage requirements.
  • Class E insulation: Provides a defined thermal insulation classification.
  • 10% voltage regulation: Provides a specified indication of secondary voltage variation under changing load conditions.
  • Compact dimensions: The 96 × 87 × 103 mm format assists with electrical panel layout planning.
  • 2.8 kg weight: Allows suitable mechanical support and mounting arrangements to be specified.
  • Enclosure compatibility references: EPH 2 or EPN 1 options are identified for installation planning.
  • Single-phase construction: Suitable for dedicated AC control voltage transformation.

Key Features

  • Manufacturer: ETE.
  • Series: WV Wide-Input-Voltage Control Transformers.
  • Model: WV200P7S8.
  • Rated apparent power: 200 VA.
  • Rated capacity: 0.2 kVA.
  • Transformer type: Single-phase industrial control transformer.
  • Primary terminal arrangement: 0/380/400/420/440/460/480 V.
  • Selectable primary voltages: 380–480 V AC using the specified terminal positions.
  • Secondary winding 1: 0/110/120 V.
  • Secondary winding 2: 0/110/120 V.
  • Parallel secondary configuration: 110 V or 120 V AC.
  • Series secondary configuration: 220 V or 240 V AC.
  • Winding connection flexibility: Supports series or parallel connection of the two secondary windings.
  • Insulation class: E.
  • Voltage regulation: 10%.
  • Length: 96 mm.
  • Width: 87 mm.
  • Height: 103 mm.
  • Weight: 2.8 kg.
  • Associated enclosure references: EPH 2 or EPN 1.

Flexible Industrial Control Power with Series and Parallel Secondary Connections

The ETE WV200P7S8 is designed to accommodate a range of industrial primary supply voltages while providing selectable secondary control voltages. Its primary terminals cover nominal voltage selections of 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC, making it suitable for equipment operating on different industrial electrical supply arrangements. The correct primary terminal must be selected to match the actual supply and the manufacturer's connection instructions.

A key advantage is its two separate 0/110/120 V secondary windings. When connected correctly in parallel, the windings provide a nominal 110 V AC or 120 V AC output. Parallel operation allows the current contribution of both windings to be combined, subject to the transformer's overall 200 VA rating. The windings must be connected using matching voltage taps and the correct polarity; incorrect parallel connections can cause damaging circulating currents.

When connected correctly in series, the secondary windings provide a nominal 220 V AC or 240 V AC output. This configuration combines the voltages of the two secondary windings while retaining the transformer's overall apparent power rating. Correct winding polarity and terminal identification are essential, as an incorrect series connection may result in voltage cancellation or an unsuitable output.

At the rated 200 VA capacity, the calculated nominal output currents are approximately 1.82 A at 110 V, 1.67 A at 120 V, 0.91 A at 220 V and 0.83 A at 240 V. These are calculated values based on apparent power divided by nominal voltage, not separately verified manufacturer current ratings. The 200 VA rating applies to the transformer as a whole and must not be interpreted as 200 VA available independently from each secondary winding.

The specified 10% voltage regulation is relevant when assessing secondary voltage variation under changing load conditions. Actual output voltage depends on the primary supply, selected taps and connected load. Equipment with narrow operating voltage tolerances should therefore be checked for compatibility, especially where control relays, contactor coils or other inductive devices introduce changing loads.

With Class E insulation, a compact physical format and associated EPH 2 or EPN 1 enclosure references, the WV200P7S8 is suitable for integration into appropriately engineered industrial electrical assemblies. Installers should provide suitable mounting, primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances. Series and parallel winding connections must follow the manufacturer's wiring instructions.

Typical Applications

  • Industrial control panels requiring selectable 110 V or 120 V AC supplies.
  • Industrial control panels requiring selectable 220 V or 240 V AC supplies.
  • Machinery operating with compatible 380–480 V AC primary supply arrangements.
  • OEM machinery and industrial automation systems.
  • Control relays and contactors with compatible AC coil voltages.
  • Motor control panels requiring dedicated AC control power.
  • Industrial signalling and indication circuits.
  • Electrical machinery with selectable control voltage requirements.
  • Control transformer replacement and maintenance projects.
  • Industrial process control equipment with suitable AC loads.
  • Electrical panel building and system integration.
  • Equipment requiring series-connected or parallel-connected transformer secondary windings.
  • Control circuit upgrades requiring a 200 VA multi-voltage transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 200 VA
Primary Voltage 0/380/400/420/440/460/480V
Secondary Voltage 0/110/120V + 0/110/120V
Phase Single Phase
Manufacturer ETE
Product series WV Wide-Input-Voltage Control Transformers
Manufacturer part number WV200P7S8
Product type Wide-input-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 200 VA
Rated capacity 0.2 kVA
Primary terminals 0/380/400/420/440/460/480 V
Nominal primary voltage options 380 V, 400 V, 420 V, 440 V, 460 V or 480 V AC
Number of secondary windings 2
Secondary winding 1 terminals 0/110/120 V
Secondary winding 2 terminals 0/110/120 V
Parallel output option 1 110 V AC
Parallel output option 2 120 V AC
Series output option 1 220 V AC
Series output option 2 240 V AC
Secondary connection arrangement 110/120 V parallel or 220/240 V series
Calculated secondary current at 110 V parallel Approximately 1.82 A at 200 VA
Calculated secondary current at 120 V parallel Approximately 1.67 A at 200 VA
Calculated secondary current at 220 V series Approximately 0.91 A at 200 VA
Calculated secondary current at 240 V series Approximately 0.83 A at 200 VA
Insulation class E
Voltage regulation 10%
Length 96 mm
Width 87 mm
Height 103 mm
Dimensions (L × W × H) 96 × 87 × 103 mm
Weight 2.8 kg
Enclosure reference EPH 2 or EPN 1
Product range ETE Stock Control Transformers
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE WV200P7S8 used for?

The ETE WV200P7S8 is a 200 VA single-phase wide-input-voltage control transformer used to supply compatible industrial control circuits, machinery and electrical panels with selectable 110 V, 120 V, 220 V or 240 V AC outputs.

What is the power rating of the ETE WV200P7S8?

The transformer has a rated apparent power of 200 VA (0.2 kVA). This is the overall transformer rating and applies to the combined load on its secondary windings.

What primary voltages does the WV200P7S8 support?

The transformer features 0/380/400/420/440/460/480 V primary terminals, supporting nominal primary voltage selections of 380 V, 400 V, 420 V, 440 V, 460 V or 480 V AC using the appropriate terminal connection.

What secondary voltages can the WV200P7S8 provide?

The transformer supports 110 V or 120 V AC with the secondary windings connected in parallel, and 220 V or 240 V AC with the secondary windings connected in series, using the manufacturer's specified wiring arrangements.

How many secondary windings does the WV200P7S8 have?

The WV200P7S8 has two secondary windings, each with 0/110/120 V terminals. The windings can be connected in the specified series or parallel configurations.

Can the WV200P7S8 provide 110 V or 120 V AC in parallel?

Yes. The two secondary windings can be connected in parallel to provide a nominal 110 V AC or 120 V AC output. Matching taps and correct winding polarity are essential, and the combined load must remain within the 200 VA rating.

Can the WV200P7S8 provide 220 V or 240 V AC in series?

Yes. The two secondary windings can be connected in series to provide a nominal 220 V AC or 240 V AC output. The correct series connection and winding polarity must be followed according to the manufacturer's instructions.

What is the calculated secondary current at 110 V?

At the rated 200 VA capacity and a nominal 110 V AC parallel output, the calculated current is approximately 1.82 A. This is a calculated value rather than a separately verified manufacturer current rating.

What is the calculated secondary current at 120 V?

At the rated 200 VA capacity and a nominal 120 V AC parallel output, the calculated current is approximately 1.67 A. This is a calculated value rather than a separately verified manufacturer current rating.

What is the calculated secondary current at 220 V or 240 V?

At the rated 200 VA capacity, the calculated current is approximately 0.91 A at 220 V AC or 0.83 A at 240 V AC with the secondary windings correctly connected in series. These are calculated values rather than separately verified manufacturer current ratings.

What does the 10% voltage regulation specification mean?

The WV200P7S8 has a specified 10% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should have suitable operating voltage tolerance.

What insulation class does the ETE WV200P7S8 use?

The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.

What are the dimensions and weight of the ETE WV200P7S8?

The transformer measures 96 × 87 × 103 mm (L × W × H) and weighs 2.8 kg. These details assist with electrical panel layout and mounting arrangements.

Which enclosure references are associated with the WV200P7S8?

The associated enclosure references are EPH 2 or EPN 1. The appropriate enclosure and its suitability for the installation should be confirmed before selection.

What should be checked before installing the ETE WV200P7S8?

Before installation, select the correct primary terminal for the supply voltage, confirm the required secondary voltage and follow the manufacturer's series or parallel wiring instructions. Check the combined connected load against the 200 VA rating and provide suitable circuit protection, conductor sizing, mounting, ventilation and electrical clearances.

Trusted by Industrial Panel Builders and Automation Engineers

ETE WV wide-input-voltage control transformers offer a flexible solution for industrial electrical applications requiring multiple primary voltage selections and configurable secondary outputs. With six nominal primary voltage options, dual 0/110/120 V secondary windings, series or parallel output connections, a 200 VA rating and Class E insulation, the WV200P7S8 provides electrical panel builders, machinery manufacturers and automation engineers with a practical option for industrial control power.