ETE WV1500P7S7 is a 1500 VA single-phase wide-input-voltage control transformer with 0/380/400/420/440/460/480V primary terminals, dual 0/24V secondary windings configurable for 24 V parallel or 48 V series output, Class E insulation and 4% voltage regulation.
£154.88
The ETE WV1500P7S7 is a powerful 1500 VA single-phase wide-input-voltage control transformer designed to provide dependable AC voltage transformation and electrical isolation for industrial machinery, electrical control panels and automation systems. As part of the ETE WV stock control transformer range, it combines substantial apparent power capacity with multiple primary voltage connections and configurable secondary windings, making it a practical choice for industrial control panel builders, OEM machinery manufacturers and electrical maintenance engineers.
The WV1500P7S7 features primary terminals marked 0/380/400/420/440/460/480 V, providing six nominal input voltage options for industrial electrical installations. Its dual 0/24 V secondary windings can be connected in parallel to provide a 24 V AC output or in series to provide a 48 V AC output. This flexible secondary arrangement allows the same transformer model to support different industrial control voltage requirements while maintaining a total rated apparent power of 1500 VA.
With Class E insulation and 4% voltage regulation, the ETE WV1500P7S7 offers a combination of control power capacity, voltage flexibility and relatively low specified voltage regulation. Measuring 150 × 151 × 145 mm and weighing 14.2 kg, it is suitable for integration into appropriately designed industrial electrical equipment, with an associated EPN 4 enclosure reference. Its 1500 VA rating makes it particularly relevant to control systems with substantial combined auxiliary AC power requirements.
The ETE WV1500P7S7 transforms a selected industrial AC input voltage into a lower secondary voltage suitable for compatible control equipment. Its six nominal primary voltage connections support installations using 380 V, 400 V, 420 V, 440 V, 460 V or 480 V AC supplies. This flexibility can simplify transformer selection across machinery and electrical installations with different nominal supply voltages, provided the correct primary terminal is selected and connected according to ETE's instructions.
On the secondary side, the transformer incorporates two separate 24 V AC windings. When correctly connected in parallel, the windings provide 24 V AC. When connected in series with additive polarity, they provide 48 V AC. Parallel connections require matching winding polarity, and incorrect connections can cause damaging circulating currents or an unsuitable output voltage. The manufacturer's terminal identification and wiring instructions must be followed before energising the transformer.
The 1500 VA rating represents the transformer's total rated apparent power, rather than a separate 1500 VA allowance for each secondary winding. This capacity makes the WV1500P7S7 relevant to industrial control systems with substantial combined AC power demands, provided connected equipment remains within the transformer's permitted continuous and starting-load ratings. Its specified 4% voltage regulation should also be considered when selecting voltage-sensitive control equipment, as the secondary voltage can vary with loading.
With Class E insulation, a 14.2 kg weight and an associated EPN 4 enclosure reference, the WV1500P7S7 is intended for integration into appropriately engineered electrical installations. Suitable mechanical support is particularly important for a transformer of this weight. The installation should also incorporate appropriate circuit protection, ventilation, earthing, conductor sizing and safe access for inspection and maintenance.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 1500 VA | |
|---|---|---|
| Primary Voltage | 0/380/400/420/440/460/480V | |
| Secondary Voltage | 0/24V + 0/24V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product range | WV Wide-Input-Voltage Stock Control Transformers | |
| Model / SKU | WV1500P7S7 | |
| Product type | Wide-input-voltage industrial control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 1500 VA | |
| Primary terminals | 0/380/400/420/440/460/480V | |
| Nominal primary voltage options | 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC | |
| Number of nominal primary voltage options | 6 | |
| Secondary terminals | 0/24V + 0/24V | |
| Secondary winding configuration | Two 24 V AC windings | |
| Parallel output connection | 24 V AC | |
| Series output connection | 48 V AC | |
| Insulation class | E | |
| Voltage regulation | 4% | |
| Length | 150 mm | |
| Width | 151 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 151 × 145 mm | |
| Weight | 14.2 kg | |
| Enclosure reference | EPN 4 | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV1500P7S7 is a 1500 VA single-phase wide-input-voltage control transformer used to provide isolated 24 V or 48 V AC supplies for compatible industrial machinery, electrical control panels and automation equipment.
The transformer has a total rated apparent power of 1500 VA. This is the overall transformer capacity and does not mean that each secondary winding can independently supply 1500 VA.
Its primary terminals are marked 0/380/400/420/440/460/480V, providing nominal input voltage options of 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC.
The transformer has dual 0/24V secondary windings. They can be connected in parallel for 24 V AC or in series for 48 V AC, using the appropriate winding connections.
For 24 V AC, the two secondary windings are connected in parallel with matching polarity. For 48 V AC, they are connected in series with additive polarity. All wiring must follow ETE's terminal identification and connection instructions.
The transformer has Class E insulation, providing a defined thermal insulation classification for operation within the manufacturer's specified limits.
The ETE WV1500P7S7 has 4% voltage regulation. This is the specified regulation characteristic and should be considered when selecting connected equipment because secondary voltage can vary between no-load and rated-load conditions.
The transformer measures 150 × 151 × 145 mm (length × width × height) and weighs 14.2 kg. Its installation must provide suitable mechanical support.
The specified enclosure reference is EPN 4. Enclosure selection and installation should account for suitable mounting support, ventilation, electrical protection and access for wiring and maintenance.
Yes. Its 1500 VA total rated capacity can support multiple compatible devices, provided their combined apparent power, starting demands and operating requirements remain within the transformer's overall and individual winding limits.
Yes. The transformer includes a nominal 400 V AC primary connection, alongside 380 V, 420 V, 440 V, 460 V and 480 V AC options. The correct primary terminal must be selected and wired according to the manufacturer's instructions.
The ETE WV1500P7S7 combines 1500 VA capacity, six nominal primary voltage options and configurable dual 24 V secondary windings in a substantial industrial control transformer. With 24 V parallel or 48 V series output, Class E insulation and 4% voltage regulation, it provides a flexible solution for compatible industrial control and auxiliary AC power applications.