ETE WV1000P7S8 is a 1000 VA single-phase wide-input-voltage control transformer with selectable 380–480 V AC primary taps, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 4% voltage regulation.
£128.03
The ETE WV1000P7S8 is a versatile 1000 VA single-phase wide-input-voltage control transformer designed for industrial electrical control panels, machinery, switchgear and automation systems. Part of the ETE WV wide-input-voltage control transformer range, it combines multiple primary voltage taps with configurable dual secondary windings, providing flexible AC voltage conversion for industrial installations requiring a higher-capacity control power supply.
The WV1000P7S8 features a 0/380/400/420/440/460/480 V primary terminal arrangement, supporting compatible 380, 400, 420, 440, 460 and 480 V AC supplies. Its two 0/110/120 V secondary windings can be connected in parallel for 110 V or 120 V AC, or in series for 220 V or 240 V AC. This flexibility makes the transformer suitable for industrial control equipment with different operating voltage requirements.
With a rated apparent power of 1000 VA (1 kVA), Class E insulation and 4% voltage regulation, the WV1000P7S8 provides a practical solution for appropriately rated industrial control circuits. Its dimensions of 150 × 125 × 145 mm and weight of 9.8 kg make it suitable for installation in electrical control cabinets with adequate mounting space and mechanical support. The specified enclosure reference is EPN 3.
The ETE WV1000P7S8 is designed for industrial control installations where the available primary supply voltage may differ between machines, facilities or electrical systems. Its selectable primary terminals support 380, 400, 420, 440, 460 and 480 V AC, allowing the transformer to be configured for several compatible industrial supply voltages.
The transformer incorporates two secondary windings, each with 0/110/120 V terminals. Connecting matching secondary winding taps in parallel with the correct polarity provides 110 V or 120 V AC. Connecting the windings in series with the correct additive polarity provides 220 V or 240 V AC. All winding connections must follow ETE's instructions to ensure correct voltage selection and safe operation.
Based on its 1000 VA rating, the theoretical full-load secondary current is approximately 9.09 A at 110 V AC, 8.33 A at 120 V AC, 4.55 A at 220 V AC or 4.17 A at 240 V AC. These calculated values assume the full rated apparent power is available in the selected configuration. Actual permissible winding currents and loading requirements must follow ETE's specifications.
The specified 4% voltage regulation means secondary voltage variation between operating load conditions should be considered when selecting connected equipment. Correct primary tap selection, secondary winding polarity, suitable circuit protection, conductor sizing and appropriate installation clearances are essential for safe operation. Sensitive electronic equipment requiring a tightly regulated supply may need additional voltage regulation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 1000 VA | |
|---|---|---|
| Primary Voltage | 0/380/400/420/440/460/480V | |
| Secondary Voltage | 0/110/120V + 0/110/120V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | WV Wide-Input-Voltage Control Transformers | |
| Model | WV1000P7S8 | |
| Product type | Wide-input-voltage control transformer | |
| Rated apparent power | 1000 VA (1 kVA) | |
| Number of phases | Single-phase | |
| Primary terminal arrangement | 0/380/400/420/440/460/480 V | |
| Primary voltage options | 380/400/420/440/460/480 V AC | |
| Secondary terminal arrangement | 0/110/120 V + 0/110/120 V | |
| Secondary winding configuration | Dual windings, series or parallel | |
| Parallel secondary output | 110/120 V AC | |
| Series secondary output | 220/240 V AC | |
| Voltage regulation | 4% | |
| Insulation class | E | |
| Length | 150 mm | |
| Width | 125 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 125 × 145 mm | |
| Weight | 9.8 kg | |
| Enclosure reference | EPN 3 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV1000P7S8 is a 1000 VA single-phase wide-input-voltage control transformer designed to convert compatible 380–480 V AC supplies into selectable 110/120 V or 220/240 V AC outputs for industrial control circuits, machinery and automation equipment.
The transformer features a 0/380/400/420/440/460/480 V primary terminal arrangement, supporting selectable 380, 400, 420, 440, 460 and 480 V AC supply connections.
The transformer provides 110 V or 120 V AC when its secondary windings are connected in parallel, or 220 V or 240 V AC when they are connected in series.
The transformer has a rated apparent power of 1000 VA (1 kVA), making it suitable for appropriately rated industrial control, signalling and automation applications.
The two 0/110/120 V secondary windings must be connected according to ETE's wiring instructions. Parallel operation requires matching winding voltages and correct polarity, while series operation requires the correct additive-polarity connection to obtain 220 V or 240 V AC.
Based on the 1000 VA rating, the theoretical full-load secondary current is approximately 9.09 A at 110 V AC, 8.33 A at 120 V AC, 4.55 A at 220 V AC or 4.17 A at 240 V AC, assuming the full rating is available in the selected configuration. Actual permissible loading must follow ETE's specifications.
The specified 4% voltage regulation describes the transformer's secondary voltage variation between load conditions. Connected equipment should tolerate the resulting voltage variation, and additional regulation may be required for voltage-sensitive devices.
The transformer measures 150 mm long × 125 mm wide × 145 mm high and weighs 9.8 kg, making it suitable for appropriately sized industrial control cabinets with adequate mechanical support.
The transformer features Class E insulation and specifies EPN 3 as its enclosure reference. The appropriate enclosure and mounting arrangement should be selected according to installation requirements.
The ETE WV1000P7S8 combines a 1000 VA (1 kVA) rating, six selectable primary voltage taps, configurable 110/120 V and 220/240 V AC secondary outputs, Class E insulation and 4% voltage regulation. Its wide-input-voltage design makes it a practical choice for industrial control panel builders, OEM machinery manufacturers and electrical maintenance engineers requiring flexible, higher-capacity AC control voltage conversion.