Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE SV50P5S5 is a 50 VA single-phase single-voltage control transformer with 0/415V primary terminals, 0/240V secondary terminals, 240 V AC output, Class E insulation, 15% voltage regulation, EPH 1 or EPN 1 enclosure references, dimensions of 75 x 65 x 88 mm and a weight of 1 kg.
£17.18
The ETE SV50P5S5 is a compact 50 VA single-phase single-voltage control transformer designed to provide a nominal 240 V AC secondary output from a 415 V AC primary supply. Part of the ETE SV single-voltage control transformer range, it offers a straightforward voltage transformation solution for industrial control panels, machinery control circuits and compatible auxiliary electrical equipment.
Featuring primary terminals marked 0/415V and secondary terminals marked 0/240V, the SV50P5S5 is intended for applications where a defined 415 V AC input must be transformed to a lower 240 V AC control voltage. Its 50 VA rated apparent power makes it suitable for appropriately sized control loads, including compatible relays, contactor coils, indication equipment and other industrial AC control devices. The specified 15% voltage regulation is an important consideration when assessing secondary voltage variation under different loading conditions.
With dimensions of just 75 × 65 × 88 mm and a weight of 1 kg, the ETE SV50P5S5 provides a space-conscious solution for industrial electrical assemblies. It features Class E insulation and is associated with the enclosure references EPH 1 or EPN 1, as listed in the ETE Stock Control Transformer Range, March 2026. Its combination of compact construction, defined primary and secondary voltages and practical control power capacity makes it a useful choice for new panel builds, equipment maintenance and compatible transformer replacement projects.
The ETE SV50P5S5 is designed for industrial applications requiring a 240 V AC control supply derived from a nominal 415 V AC input. Its primary terminal arrangement is marked 0/415V, while the secondary is marked 0/240V. This fixed nominal voltage arrangement is particularly useful when the available supply and required control voltage are already established during electrical system design.
As a single-voltage control transformer, the SV50P5S5 should be selected for the specified primary and secondary connections rather than assumed to offer alternative voltage taps. The primary voltage must be compatible with the installation, and the connected secondary equipment must be suitable for the transformer's nominal 240 V AC output. The transformer provides galvanic isolation between its primary and secondary circuits, but its specification does not establish a particular Class II protection classification, SELV output classification or other unlisted safety approval.
The transformer's 50 VA rating is the key starting point when assessing load suitability. At a nominal secondary voltage of 240 V, dividing 50 VA by 240 V gives approximately 0.21 A. This is a theoretical apparent-power sizing reference, not a separately published manufacturer current rating. The combined steady-state demand of connected equipment must be assessed, together with any relevant starting or inrush requirements, before selecting the transformer.
The specified 15% voltage regulation is particularly relevant to control circuit design. Transformer voltage regulation describes the change in secondary voltage between specified loading conditions, commonly expressed relative to the rated-load secondary voltage. It does not mean the transformer actively stabilises its output to within ±15%. Engineers should therefore consider how the secondary voltage may vary with loading and verify that connected control components can operate correctly throughout the expected conditions.
With Class E insulation, a 75 × 65 × 88 mm physical size and a 1 kg weight, the SV50P5S5 is well suited to consideration in compact control panel layouts. The catalogue identifies EPH 1 or EPN 1 as enclosure references; the appropriate arrangement and any associated installation requirements should be confirmed against ETE documentation. These references must not be treated as independently verified ingress protection ratings.
Installation and commissioning should be performed by suitably qualified personnel. The installation must incorporate appropriate primary and secondary circuit protection, conductor sizing, mechanical support, ventilation and electrical clearances. The transformer should be installed in accordance with ETE's instructions and applicable electrical requirements, with particular attention to supply voltage, connected load and the protection needs of the complete control circuit.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 50 VA | |
|---|---|---|
| Primary Voltage | 0/415V | |
| Secondary Voltage | 0/240V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product range | SV Single-Voltage Control Transformers | |
| Model / SKU | SV50P5S5 | |
| Product type | Single-voltage control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 50 VA | |
| Primary terminals | 0/415V | |
| Nominal primary voltage | 415 V AC | |
| Secondary terminals | 0/240V | |
| Output connection | 240 V AC | |
| Insulation class | E | |
| Voltage regulation | 15% | |
| Length | 75 mm | |
| Width | 65 mm | |
| Height | 88 mm | |
| Dimensions (L × W × H) | 75 × 65 × 88 mm | |
| Weight | 1 kg | |
| Enclosure reference | EPH 1 or EPN 1 | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE SV50P5S5 is a 50 VA single-phase single-voltage control transformer designed to provide a nominal 240 V AC secondary output from a 415 V AC primary supply. It is suitable for appropriately sized industrial control and auxiliary circuits.
The transformer has a rated apparent power of 50 VA. Connected equipment must be selected so that its combined operating and starting requirements remain within the transformer's permitted limits.
The transformer has primary terminals marked 0/415V and is specified for a nominal 415 V AC primary input.
The secondary terminals are marked 0/240V, providing a nominal 240 V AC output for compatible control equipment.
The single-voltage designation identifies a transformer with the specified primary and secondary voltage arrangement. The SV50P5S5 has 0/415V primary terminals and 0/240V secondary terminals; alternative voltage taps are not listed in the supplied specification.
The stated 15% voltage regulation describes the transformer's secondary voltage variation between specified loading conditions. It does not indicate active electronic voltage stabilisation or a guaranteed ±15% output tolerance. Connected equipment should be suitable for the expected secondary voltage variation.
The transformer has Class E insulation. This is a thermal insulation classification and should not be confused with an electrical protection class such as Class II.
The ETE catalogue lists EPH 1 or EPN 1 as the enclosure reference. The appropriate enclosure arrangement should be confirmed against ETE's product documentation. These references do not independently establish an ingress protection rating.
The transformer measures 75 × 65 × 88 mm (length × width × height) and weighs 1 kg.
Dividing the 50 VA apparent power rating by the nominal 240 V secondary voltage gives approximately 0.21 A. This is a theoretical sizing calculation, not an independently stated manufacturer output current rating. Actual load selection must follow the transformer's operating limits.
Yes, the transformer may be suitable for compatible 240 V AC contactors and relays, provided their combined steady-state and starting requirements are within the transformer's permitted capacity. Coil voltage tolerance and the transformer's 15% voltage regulation should also be considered during selection.
The ETE SV50P5S5 combines a 50 VA rated apparent power, a nominal 415 V AC primary input and a dedicated 240 V AC secondary output in a compact single-phase control transformer. With Class E insulation, specified 15% voltage regulation, EPH 1 or EPN 1 enclosure references and dimensions of 75 × 65 × 88 mm, it provides a practical option for compatible industrial control circuits, electrical panel builds and transformer replacement projects.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.