Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE SV500P4S4 is a 500 VA single-phase SV series industrial control transformer with a 240 V AC primary, 110 V AC secondary, Class E insulation and 8% voltage regulation for electrical control panels and industrial automation applications.
£61.88
The ETE SV500P4S4 is a robust and reliable 500 VA single-phase industrial control transformer designed to convert a 240 V AC primary supply into a 110 V AC secondary output. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the established ETE SV single-voltage stock control transformer series, developed for electrical panel builders, machinery manufacturers and industrial automation applications requiring a dependable control circuit power supply.
Designed for continuous operation, the SV500P4S4 features durable industrial construction with Class E insulation, Class H varnish impregnation and high-specification IP20 touch-proof terminals. Its dedicated core earth terminal supports protective earthing, while its single-input and single-output voltage configuration simplifies wiring and integration into industrial electrical systems.
With a rated apparent power of 500 VA, 0/240 V primary terminals and 0/110 V secondary terminals, the ETE SV500P4S4 provides a nominal 110 V AC control supply for compatible industrial electrical equipment. Its dimensions of 120 × 120 × 120 mm and specified weight of 6.2 kg make it suitable for installation inside electrical control cabinets, machinery panels and appropriately selected transformer enclosures.
Industrial control transformers provide a dedicated electrical supply for control circuits and auxiliary equipment. The ETE SV500P4S4 uses electromagnetic induction to convert a nominal 240 V AC primary input into a 110 V AC secondary output. Its separate primary and secondary windings provide electrical isolation between the supply and control circuits, allowing compatible control devices to operate from a transformer-fed supply.
The 500 VA continuous rating makes the SV500P4S4 suitable for industrial control systems requiring a nominal 110 V AC supply. At its rated secondary voltage, the transformer has a calculated full-load secondary current of approximately 4.55 A, based on its 500 VA apparent power rating. Actual transformer selection should account for the total connected load, permissible voltage variation, operating conditions and short-duration inrush current requirements.
The ETE SV range is designed for straightforward integration into industrial electrical assemblies. Its Class E insulation system, Class H varnish impregnation and IP20 touch-proof terminals provide durable construction for control panel applications. The specified 8% voltage regulation should be considered when assessing secondary voltage variation between no-load and loaded conditions.
For installations requiring additional physical protection, the SV500P4S4 can be incorporated into an appropriately selected EPH 3 or EPN 2 enclosure. Correct primary and secondary circuit protection, protective earthing, ventilation and compliance with applicable electrical installation requirements are essential for safe and reliable operation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 500 VA | |
|---|---|---|
| Primary Voltage | 0/240V | |
| Secondary Voltage | 0/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | SV Single-Voltage Stock Control Transformer Range | |
| Model | SV500P4S4 | |
| Product type | Industrial control circuit transformer | |
| Transformer configuration | Single-voltage primary and single-voltage secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 500 VA | |
| Primary voltage | 240 V AC | |
| Primary terminals | 0/240 V | |
| Secondary voltage | 110 V AC | |
| Secondary terminals | 0/110 V | |
| Output connection | 110 V | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | Class E | |
| Varnish impregnation | Class H | |
| Voltage regulation | 8% | |
| Terminal protection | IP20 touch-proof terminals | |
| Core earthing | Dedicated core earth terminal | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Applicable design standard | EN 61558-1 | |
| Calculated full-load secondary current | Approximately 4.55 A | |
| Length | 120 mm | |
| Width | 120 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 120 × 120 mm | |
| Weight | 6.2 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Installation type | Electrical control panel or suitable enclosure mounting | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE SV500P4S4 is a single-phase industrial control transformer designed to convert a 240 V AC supply into a 110 V AC output for compatible electrical control circuits, machinery and industrial automation equipment.
The transformer has a rated apparent power of 500 VA and is designed for continuous operation within its specified electrical and environmental limits.
The SV500P4S4 has 0/240 V primary terminals and 0/110 V secondary terminals, providing a nominal 110 V AC output when supplied from a 240 V AC input.
Based on its 500 VA rating and 110 V AC nominal secondary voltage, the transformer has a calculated full-load secondary current of approximately 4.55 A. Connected loads must remain within the transformer's rated capacity and applicable operating limits.
The ETE SV500P4S4 uses a Class E insulation system designed in accordance with EN 61558-1. Its windings also feature protective Class H varnish impregnation.
The transformer measures 120 mm long, 120 mm wide and 120 mm high, with a specified weight of 6.2 kg.
The ETE SV500P4S4 has a specified 8% voltage regulation, which should be considered when assessing secondary voltage requirements under changing load conditions.
The specified enclosure references are EPH 3 or EPN 2. The appropriate enclosure should be selected according to the installation environment, mounting requirements and applicable electrical safety regulations.
Yes. The transformer is designed for industrial control applications and can be installed within a suitable electrical control panel or enclosure, with appropriate ventilation, electrical protection and protective earthing.
No. The ETE SV500P4S4 provides a nominal 110 V AC secondary output, not 110 V DC. Applications requiring a DC supply need suitable rectification, filtering and regulation equipment or a dedicated DC power supply.
ETE SV single-voltage control transformers are designed to deliver dependable voltage conversion for industrial electrical installations. With its 500 VA continuous rating, 240 V AC primary, 110 V AC secondary, Class E insulation and robust industrial construction, the ETE SV500P4S4 provides a practical solution for control panel manufacturing, machine building and industrial automation applications requiring reliable 110 V AC control power.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.