ETE MV7500P2S1 Multi-Voltage Control Transformer 7500VA 20/0/380/420V to 0/55/110V

ETE MV7500P2S1 Multi-Voltage Control Transformer 7500VA 20/0/380/420V to 0/55/110V

ETE MV7500P2S1 is a 7500 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V AC or 110 V AC secondary connections, Class F insulation and 2% voltage regulation for industrial control applications.

SKU: MV7500P2S1MPN: MV7500P2S1
Price
List Price £881.00 ex VAT
Your Price (ex VAT) Save 25%
£660.75 25% OFF
You save £220.25 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £660.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£660.75

Why Choose the ETE MV7500P2S1 Multi-Voltage Control Transformer?

The ETE MV7500P2S1 is a heavy-duty 7500 VA (7.5 kVA) single-phase multi-voltage control transformer designed to provide reliable electrical isolation and flexible AC voltage connections for industrial machinery, electrical control panels and automation systems. Part of the ETE MV Multi-Voltage transformer series, it features primary terminals marked 20/0/380/420 V and secondary terminals marked 0/55/110 V, providing selectable 55 V AC or 110 V AC output connections.

Manufactured by Eastern Transformers & Equipment (ETE), the MV7500P2S1 combines a substantial 7.5 kVA power rating with Class F insulation and 2% voltage regulation. Its multi-voltage winding configuration makes it suitable for industrial installations requiring a dedicated control transformer with adaptable primary supply connections and selectable secondary voltage taps.

Measuring 300 × 330 × 330 mm and weighing 70 kg, the MV7500P2S1 is designed for substantial industrial electrical installations. The specified ETS 1 enclosure reference assists with enclosure selection, while the 20 V primary adjustment tap provides additional connection flexibility. The correct adjustment tap connections must be confirmed with ETE before installation.

Key Advantages

  • 7500 VA (7.5 kVA) rated capacity for substantial industrial control power requirements.
  • Multi-voltage primary terminals marked 20/0/380/420 V for compatible industrial supply arrangements.
  • Selectable 55 V AC or 110 V AC secondary connections for different control circuit requirements.
  • 20 V primary adjustment tap provides additional voltage connection flexibility, subject to ETE confirmation.
  • 2% voltage regulation supports consistent secondary voltage performance under changing load conditions.
  • Class F insulation provides a robust insulation system for industrial transformer applications.
  • Single-phase transformer construction for integration into compatible electrical control systems.
  • Electrical isolation between primary and secondary windings.
  • ETS 1 enclosure reference supports selection of a suitable protective enclosure.
  • Heavy-duty construction suitable for industrial panel building and machinery applications.

Key Features

  • ETE MV Multi-Voltage transformer series.
  • 7500 VA (7.5 kVA) rated apparent power.
  • Single-phase control transformer.
  • Primary terminals: 20/0/380/420 V.
  • Secondary terminals: 0/55/110 V.
  • 55 V AC or 110 V AC output connections.
  • 20 V primary adjustment tap; confirm connections with ETE.
  • 2% voltage regulation.
  • Class F insulation system.
  • ETS 1 enclosure reference.
  • 300 × 330 × 330 mm dimensions.
  • 70 kg transformer weight.
  • Suitable for installation within appropriately designed industrial electrical equipment.

High-Capacity Multi-Voltage Control Power for Industrial Equipment

The ETE MV7500P2S1 provides a practical solution for industrial systems requiring a substantial isolated AC control supply. Its 20/0/380/420 V primary terminal arrangement accommodates compatible industrial supply configurations, while its 0/55/110 V secondary terminals provide selectable output connections for appropriately rated control equipment.

The transformer includes a 20 V primary adjustment tap intended to provide additional connection flexibility. This adjustment must not be treated as a separate 20 V output. The correct terminal configuration, including the adjustment tap arrangement, should be confirmed directly with ETE and the applicable connection documentation before energising the transformer.

Its 7500 VA capacity makes it suitable for larger control circuit loads, subject to appropriate load assessment and protection. The specified 2% voltage regulation indicates comparatively small secondary voltage variation between the manufacturer's defined loading conditions, supporting dependable performance for compatible electrical control equipment.

The Class F insulation system supports transformer thermal performance, while the ETS 1 enclosure reference provides an identification point when planning installation protection. Given the unit's 70 kg weight, installation should include suitable mechanical support, lifting arrangements and secure fixing in accordance with the manufacturer's instructions.

Typical Applications

  • Industrial electrical control panels requiring high-capacity isolated AC power.
  • Machinery control systems using compatible 380 V or 420 V primary connections.
  • Industrial 55 V AC or 110 V AC control circuits.
  • Large contactor, relay and control equipment assemblies within the transformer rating.
  • Manufacturing machinery and production line control systems.
  • Industrial automation and process control installations.
  • OEM machinery and electrical equipment manufacturing.
  • Industrial plant electrical distribution and control equipment.
  • Electrical installations requiring flexible secondary voltage taps.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 7500 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 0/55/110V
Phase Single Phase
Manufacturer Eastern Transformers & Equipment (ETE)
Series MV Multi-Voltage Transformers
Model MV7500P2S1
Product type Multi-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 7500 VA (7.5 kVA)
Primary terminals 20/0/380/420 V
Primary nominal voltage taps 380 V and 420 V
Primary adjustment tap 20 V; confirm connections with ETE
Secondary terminals 0/55/110 V
Secondary output connections 55 V or 110 V taps
Voltage regulation 2%
Insulation class F
Enclosure reference ETS 1
Length 300 mm
Width 330 mm
Height 330 mm
Dimensions (L × W × H) 300 × 330 × 330 mm
Weight 70 kg
Manufacturer range ETE stock control transformer range
Specification reference ETE stock control transformer price list, March 2026

Frequently Asked Questions

What is the ETE MV7500P2S1 used for?

The ETE MV7500P2S1 is a 7500 VA single-phase multi-voltage control transformer used to provide electrically isolated 55 V AC or 110 V AC supplies for compatible industrial control circuits, machinery and electrical equipment.

What primary input voltages does the MV7500P2S1 support?

The transformer has primary terminals marked 20/0/380/420 V, incorporating nominal 380 V and 420 V connections and a 20 V adjustment tap. The correct primary terminal arrangement must be confirmed with ETE.

What secondary output voltages are available?

The MV7500P2S1 has secondary terminals marked 0/55/110 V, providing selectable 55 V AC or 110 V AC output connections when correctly supplied and connected.

What is the purpose of the 20 V primary adjustment tap?

The 20 V primary adjustment tap provides additional flexibility in the primary winding connection arrangement. The correct terminal connections and intended use must be confirmed with ETE before installation.

What is the power rating of the ETE MV7500P2S1?

The transformer has a rated apparent power of 7500 VA (7.5 kVA), making it suitable for substantial industrial control loads within its specified capacity.

What is the voltage regulation of the MV7500P2S1?

The transformer has a specified 2% voltage regulation, describing the change in secondary voltage between the manufacturer's defined load conditions.

What are the dimensions and weight of this transformer?

The MV7500P2S1 measures 300 × 330 × 330 mm (L × W × H) and weighs 70 kg. Appropriate mechanical support and installation arrangements are essential.

What insulation class does the ETE MV7500P2S1 have?

The transformer features a Class F insulation system, providing an insulation classification suited to industrial transformer applications.

What enclosure is specified for the MV7500P2S1?

The manufacturer's specified enclosure reference is ETS 1. This reference should be used when confirming suitable enclosure arrangements with ETE.

Trusted ETE Transformer Engineering

ETE MV multi-voltage transformers provide flexible voltage connections, dependable electrical isolation and robust construction for industrial control applications. The MV7500P2S1 combines a 7500 VA rating, 20/0/380/420 V primary terminals and selectable 55 V AC or 110 V AC secondary connections with Class F insulation and 2% voltage regulation, offering a practical solution for demanding industrial control installations.