ETE MV6250P2S2 is a 6250 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, a 10/0/220/240 V tapped secondary requiring manufacturer-confirmed adjustment connections, Class F insulation, 3% voltage regulation and EPN 7 enclosure compatibility.
£506.03
The ETE MV6250P2S2 is a high-capacity 6250 VA (6.25 kVA) single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring substantial AC voltage transformation capacity. Part of the ETE MV multi-voltage control transformer range, this model features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a tapped secondary output arrangement for compatible industrial electrical equipment.
With a rated apparent power of 6250 VA, the MV6250P2S2 is particularly suitable for larger industrial installations where multiple AC-operated devices or substantial connected loads require a higher-capacity control transformer. Its multi-voltage winding arrangement provides flexibility for electrical panel builders, machinery manufacturers and industrial maintenance engineers working with compatible primary supplies and secondary control voltage requirements.
The primary winding incorporates terminals marked 380 V and 420 V, together with additional terminals marked 20 V and 0 V. The secondary winding features terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The manufacturer's specified output arrangement is a tapped output according to the datasheet. The correct terminal combinations, particularly those involving the 10 V adjustment tap, must be confirmed with ETE before installation.
Featuring Class F insulation and 3% voltage regulation, the MV6250P2S2 provides defined electrical characteristics for demanding industrial transformer applications. Its dimensions of 245 × 250 × 230 mm and weight of 58 kg should be considered when planning electrical cabinet layouts, mounting arrangements and mechanical support.
The specified compatible enclosure reference is ETE EPN 7. Listed in the ETE Stock Control Transformer Range, March 2026, the MV6250P2S2 is a practical option for industrial installations requiring a substantial single-phase transformer with configurable AC output connections.
The ETE MV6250P2S2 provides a high-capacity solution for industrial electrical installations requiring a transformer with multiple primary and secondary connection options. Its 20/0/380/420 V primary winding and 10/0/220/240 V secondary winding make it suitable for applications where a compatible industrial AC supply must be transformed to an appropriate AC control or auxiliary voltage.
The primary winding incorporates terminals marked 380 V and 420 V, together with additional terminals marked 20 V and 0 V. These markings identify the available winding connections but do not independently establish every permissible supply voltage combination. The exact primary terminal arrangement should be verified against ETE's approved wiring diagram before the transformer is energised.
The secondary winding features terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The manufacturer's specification describes the output as a tapped output, with the correct terminal configuration defined by the datasheet. The 10 V terminal should not be assumed to provide an independent 10 V output, and the relationship between the secondary terminals must be confirmed with ETE.
At the total rated apparent power of 6250 VA, the calculated current equivalents are approximately 28.41 A at 220 V and 26.04 A at 240 V. These figures are calculated by dividing the rated apparent power by the nominal secondary voltage. They are theoretical values for the respective voltage levels rather than independently verified current ratings for every tapped output configuration. The permitted winding and tap loading limits must be checked before finalising the connected load.
The specified 3% voltage regulation is relevant when selecting transformers for industrial circuits containing equipment with changing electrical loads. Contactors, relays, solenoids and other electromagnetic devices can draw greater apparent power during energisation than during normal operation. Electrical designers should assess the aggregate steady-state load, simultaneous switching demands and acceptable operating voltage range of connected equipment.
The MV6250P2S2 features Class F insulation, a recognised transformer insulation thermal classification. This provides a defined basis for insulation selection, although the transformer's permissible ambient temperature, operating duty and thermal installation conditions should be confirmed against the manufacturer's technical documentation.
With a rated capacity of 6.25 kVA, the MV6250P2S2 is particularly relevant to larger industrial installations containing multiple compatible AC electrical loads. Transformer selection should consider the total apparent power requirement, winding-specific current limits, starting demands and the suitability of the selected primary and secondary connections.
The transformer measures 245 × 250 × 230 mm and weighs 58 kg. Its substantial weight requires appropriate consideration of lifting, handling, secure mounting and mechanical support. The specified compatible enclosure reference is ETE EPN 7, with final installation arrangements dependent on the intended operating environment and ventilation requirements.
The MV6250P2S2 provides AC voltage transformation rather than regulated DC output. Equipment requiring DC control voltage will need suitable additional conversion components. Installation should account for correct primary and secondary terminal selection, appropriately rated circuit protection, conductor sizing, secure mounting, ventilation and protective earthing where applicable.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 6250 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Manufacturer part number | MV6250P2S2 | |
| Product family | MV Multi-Voltage Control Transformers | |
| Product category | Industrial Control Transformers | |
| Transformer configuration | Multi-tapped primary and secondary windings | |
| Number of phases | Single-phase | |
| Rated apparent power | 6250 VA | |
| Rated apparent power in kVA | 6.25 kVA | |
| Primary terminal arrangement | 20/0/380/420 V | |
| Primary voltage terminal markings | 380 V and 420 V | |
| Additional primary terminal | 20 V | |
| Primary connection requirement | Verify permitted terminal combinations with ETE. | |
| Secondary terminal arrangement | 10/0/220/240 V | |
| Secondary voltage terminal markings | 220 V and 240 V | |
| Secondary adjustment tap | 10 V | |
| Secondary output connection | Tapped output according to the manufacturer's datasheet | |
| Adjustment tap connection note | Confirm the correct 10 V adjustment tap and associated terminal connections with ETE. | |
| Calculated apparent-power current equivalent at 220 V secondary | Approximately 28.41 A | |
| Calculated apparent-power current equivalent at 240 V secondary | Approximately 26.04 A | |
| Calculated apparent-power current equivalent at 380 V primary | Approximately 16.45 A | |
| Calculated apparent-power current equivalent at 420 V primary | Approximately 14.88 A | |
| Insulation class | F | |
| Voltage regulation | 3% | |
| Length | 245 mm | |
| Width | 250 mm | |
| Height | 230 mm | |
| Overall dimensions (L × W × H) | 245 × 250 × 230 mm | |
| Weight | 58 kg | |
| Compatible enclosure reference | EPN 7 | |
| Typical installation | Industrial electrical control panels, machinery cabinets and auxiliary electrical systems | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV6250P2S2 is a 6250 VA single-phase multi-voltage control transformer designed for industrial AC control and auxiliary circuits requiring a high-capacity transformer with tapped primary and secondary winding connections.
The transformer has a rated apparent power of 6250 VA, equivalent to 6.25 kVA. Connected equipment must remain within the applicable transformer and winding ratings.
The primary terminal markings are 20/0/380/420 V. The correct terminal combinations must be verified against ETE's approved connection information.
The secondary winding has terminals marked 10/0/220/240 V. The output is configured using the manufacturer's specified tapped connection arrangement.
The secondary includes terminals marked 220 V and 240 V. The exact nominal output available for a particular primary connection must be confirmed from ETE's approved wiring information.
The 10 V adjustment terminal provides an additional secondary winding connection. Its precise function and permitted use must be confirmed with ETE before installation.
This should not be assumed. The 10 V terminal forms part of the transformer's tapped winding arrangement, and its permitted connection method must be verified with ETE.
The transformer has primary terminals marked 380 V and 420 V, together with an additional 20 V terminal. The correct connection arrangement for a nominal 400 V AC supply must be confirmed with ETE rather than inferred from the terminal markings alone.
At 6250 VA and 220 V, the calculated current equivalent is approximately 28.41 A, assuming the total transformer rating applies to the approved output configuration.
At 6250 VA and 240 V, the calculated current equivalent is approximately 26.04 A, assuming the total transformer rating applies to the approved output configuration.
Dividing the rated apparent power by the marked primary voltages gives approximately 16.45 A at 380 V and 14.88 A at 420 V. These are mathematical apparent-power equivalents rather than independently verified operating input currents.
The MV6250P2S2 provides AC output. It does not incorporate a rectifier or regulated DC power supply.
The transformer has Class F insulation. This identifies its insulation thermal classification; permissible operating and installation temperatures should be checked against ETE's technical documentation.
The transformer has a specified 3% voltage regulation, a characteristic relevant to secondary voltage variation under changing load conditions.
The transformer measures 245 mm long × 250 mm wide × 230 mm high and weighs 58 kg.
The specified compatible enclosure reference is ETE EPN 7. Final enclosure selection should account for the installation environment, mounting requirements, ventilation and the transformer's 58 kg weight.
Yes. Its 6250 VA rating, multi-tapped windings and industrial transformer configuration make it suitable for appropriately designed electrical control panels and machinery systems using compatible AC equipment.
The correct primary and secondary wiring arrangements should be obtained from ETE or its approved technical documentation, particularly when using the 10 V secondary adjustment tap.
The ETE MV6250P2S2 combines a substantial 6250 VA rating with flexible primary connections and a tapped secondary winding incorporating 220 V and 240 V terminals. Its Class F insulation, 3% voltage regulation and EPN 7 enclosure compatibility make it a practical component for industrial electrical panel builders, machinery manufacturers and maintenance engineers requiring high-capacity configurable AC control power.