Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV6250P1S1 is a 6250 VA single-phase multi-voltage control transformer with 10/0/220/240 V primary terminals, selectable 55 V or 110 V AC secondary taps, Class F insulation, 3% voltage regulation and an EPN 7 enclosure reference.
£506.03
The ETE MV6250P1S1 is a high-capacity 6250 VA (6.25 kVA) single-phase multi-voltage control transformer designed for industrial electrical control systems, machinery and automation equipment. Part of the ETE MV stock control transformer range, it provides flexible primary voltage selection and a tapped secondary winding for applications requiring reliable AC voltage conversion.
The MV6250P1S1 features a 10/0/220/240 V primary terminal arrangement for compatible 220 V and 240 V AC supplies. Its 0/55/110 V secondary terminals provide selectable 55 V or 110 V AC outputs, allowing the transformer to serve different industrial control voltage requirements. A 10 V primary adjustment tap is also provided, with the correct connections to be confirmed with ETE.
With a substantial 6250 VA power rating, Class F insulation and 3% voltage regulation, this transformer is suitable for demanding industrial installations. Measuring 245 × 250 × 230 mm and weighing 58 kg, it requires suitable mechanical support and installation space. The specified protective enclosure reference is EPN 7.
Industrial control transformers provide voltage conversion and electrical isolation for control circuits and compatible electrical equipment. The ETE MV6250P1S1 is designed to operate from suitable 220 V or 240 V AC primary supplies and deliver a selectable 55 V or 110 V AC secondary output.
The transformer uses a 0/55/110 V tapped secondary winding, allowing the required voltage to be selected through the appropriate terminals. The 10/0/220/240 V primary arrangement also incorporates a 10 V adjustment tap. Correct primary and secondary connections must follow ETE's instructions, particularly when selecting adjustment taps.
At 110 V AC, the theoretical full-load secondary current calculated from the 6250 VA rating is approximately 56.8 A. At 55 V AC, the mathematical equivalent of the full rated power is approximately 113.6 A, but the actual permissible loading of the 55 V tap must be verified with ETE. A tapped winding must not automatically be assumed to provide the full transformer rating at every voltage selection.
The transformer's 3% voltage regulation and Class F insulation support dependable industrial performance. Its 58 kg weight requires appropriately rated mounting arrangements and safe handling procedures, together with suitable electrical protection, ventilation and conductor sizing.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 6250 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | MV Multi-Voltage Control Transformers | |
| Model | MV6250P1S1 | |
| Product type | Multi-voltage control transformer | |
| Rated apparent power | 6250 VA (6.25 kVA) | |
| Number of phases | Single-phase | |
| Primary terminal arrangement | 10/0/220/240 V | |
| Primary voltage options | 220/240 V AC | |
| Primary adjustment tap | 10 V; confirm connections with ETE | |
| Secondary terminal arrangement | 0/55/110 V | |
| Secondary output voltage | 55 V or 110 V AC | |
| Secondary connection type | Tapped output winding | |
| Voltage regulation | 3% | |
| Insulation class | F | |
| Length | 245 mm | |
| Width | 250 mm | |
| Height | 230 mm | |
| Dimensions (L × W × H) | 245 × 250 × 230 mm | |
| Weight | 58 kg | |
| Enclosure reference | EPN 7 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV6250P1S1 is a high-capacity single-phase industrial control transformer designed to convert compatible 220 V or 240 V AC supplies into selectable 55 V or 110 V AC outputs for machinery, switchgear and automation control circuits.
The transformer has a rated apparent power of 6250 VA (6.25 kVA), making it suitable for industrial applications requiring substantial AC control power.
The transformer features a 10/0/220/240 V primary terminal arrangement for compatible 220 V and 240 V AC supplies. It also includes a 10 V primary adjustment tap, with connections to be confirmed with ETE.
Yes. Its 0/55/110 V tapped secondary winding allows selection of either 55 V or 110 V AC using the appropriate terminals.
The 10 V primary adjustment tap provides an additional connection point within the multi-voltage primary arrangement. Its correct use and terminal connections must be confirmed with ETE before energising the transformer.
At its 6250 VA rating, the theoretical full-load secondary current at 110 V AC is approximately 56.8 A. The permissible current at the 55 V tap must be confirmed with ETE because the tapped winding may have a different current limitation.
The transformer measures 245 mm long × 250 mm wide × 230 mm high and weighs 58 kg. Suitable lifting, handling and mounting arrangements should be provided.
The MV6250P1S1 features Class F insulation and 3% voltage regulation, supporting dependable operation in industrial electrical installations.
The specified enclosure reference is EPN 7, identifying the corresponding ETE enclosure size for installations requiring additional protective housing.
ETE MV multi-voltage control transformers provide dependable voltage conversion solutions for industrial electrical installations. The MV6250P1S1 combines a substantial 6250 VA rating, flexible 220/240 V primary connections, selectable 55/110 V secondary taps, Class F insulation and 3% voltage regulation, making it a practical choice for industrial control panel builders, machinery manufacturers and electrical maintenance engineers.