ETE MV50P2S2 is a 50 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, 10/0/220/240 V tapped secondary terminals, a 10 V adjustment tap requiring ETE connection confirmation, Class E insulation and 15% voltage regulation.
£21.23
The ETE MV50P2S2 is a 50 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring flexible primary voltage connections and tapped secondary output arrangements. Part of the ETE MV multi-voltage transformer range, it features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a versatile transformer configuration for compatible industrial control circuits.
The MV50P2S2 incorporates secondary terminals marked 0/220/240 V, together with a 10 V adjustment tap. These connections support the manufacturer's specified tapped-output arrangements for applications requiring appropriate AC control voltages. The exact output connection must follow the ETE datasheet, and the correct use of the 10 V adjustment tap must be confirmed with ETE before installation.
With its 50 VA rated capacity, the transformer is intended for compatible low-power industrial control equipment, including control relays, signalling circuits and other electrical devices requiring a suitable AC supply. Its multi-voltage primary arrangement provides flexibility for machinery and control panel applications where the manufacturer's specified primary connections are appropriate.
Featuring Class E insulation, 15% voltage regulation, compact dimensions of 75 × 65 × 88 mm and a weight of 1 kg, the ETE MV50P2S2 is suitable for integration into appropriately designed industrial electrical assemblies. The associated enclosure references are EPH 1 or EPN 1, providing identified enclosure options for installation planning.
The ETE MV50P2S2 provides a practical solution for industrial applications requiring a compact, single-phase control transformer with multiple terminal connections. Its 20/0/380/420 V primary terminal arrangement and 10/0/220/240 V secondary terminal arrangement allow the transformer to be incorporated into compatible electrical systems using the manufacturer's specified wiring configurations.
The secondary winding includes terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The output is specified as a tapped connection according to the ETE datasheet. Although the terminal markings identify available winding connections, they should not be treated as a substitute for the manufacturer's wiring diagram. Confirm the correct connections with ETE before energising the transformer, particularly when using the 10 V adjustment tap.
The transformer's 50 VA rated capacity is intended for compatible low-power control loads. Based on the apparent power rating, the calculated current corresponding to a 220 V output is approximately 0.23 A, while the calculated current corresponding to a 240 V output is approximately 0.21 A. These figures are theoretical calculations rather than separately verified manufacturer current ratings. They do not establish that every possible terminal combination is an approved output connection.
The specified 15% voltage regulation is important when evaluating secondary voltage variation between load conditions. Actual output voltage can vary with the primary supply and connected load, so equipment with narrow voltage tolerances should be assessed carefully. For control circuits containing relays, contactors or other inductive loads, both continuous apparent power and short-duration inrush requirements should be considered.
With Class E insulation, compact physical dimensions and associated EPH 1 or EPN 1 enclosure references, the MV50P2S2 can be integrated into suitably engineered industrial control assemblies. Appropriate mounting, primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances should be provided in accordance with ETE installation instructions and applicable electrical requirements.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 50 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | MV Multi-Voltage Control Transformers | |
| Model | MV50P2S2 | |
| Product type | Multi-voltage control transformer | |
| Transformer configuration | Single-phase | |
| Rated apparent power | 50 VA | |
| Rated capacity | 0.05 kVA | |
| Primary terminal markings | 20/0/380/420 V | |
| Primary voltage terminal markings | 380 V and 420 V | |
| Additional primary terminal | 20 V | |
| Secondary terminal markings | 10/0/220/240 V | |
| Secondary voltage terminal markings | 220 V and 240 V | |
| Secondary adjustment tap | 10 V | |
| Output connection | Tapped output per ETE datasheet | |
| Adjustment tap connection requirement | Confirm terminal connections with ETE | |
| Calculated secondary current at 220 V | Approximately 0.23 A at 50 VA | |
| Calculated secondary current at 240 V | Approximately 0.21 A at 50 VA | |
| Insulation class | E | |
| Voltage regulation | 15% | |
| Length | 75 mm | |
| Width | 65 mm | |
| Height | 88 mm | |
| Dimensions (L × W × H) | 75 × 65 × 88 mm | |
| Weight | 1 kg | |
| Enclosure reference | EPH 1 or EPN 1 | |
| Product range | ETE Stock Control Transformers | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV50P2S2 is a 50 VA single-phase multi-voltage control transformer designed to provide AC voltage transformation for compatible industrial control circuits, machinery and electrical panels using its specified primary and tapped secondary connections.
The transformer has a rated apparent power of 50 VA (0.05 kVA). The connected load must remain within the transformer's overall rated capacity.
The transformer features 20/0/380/420 V primary terminals. The appropriate supply connection must follow the manufacturer's specified wiring arrangement.
The transformer has 10/0/220/240 V secondary terminals, including a 10 V adjustment tap. The correct output connection must follow the ETE datasheet.
The secondary winding includes terminals marked 220 V and 240 V. The exact approved output connections and the use of the adjustment tap must be confirmed against the ETE datasheet before installation.
The 10 V adjustment tap provides an additional connection facility within the secondary winding arrangement. Its correct use and terminal connections must be confirmed with ETE; a particular voltage adjustment should not be assumed from the terminal markings alone.
The transformer has a tapped secondary winding, but simultaneous loading of different taps should not be assumed without confirmation from ETE. Any permitted connected loads must remain within the transformer's overall 50 VA rating.
At a nominal 220 V AC output, the current corresponding to the 50 VA rating is approximately 0.23 A. This is a calculated value rather than a separately verified manufacturer current rating and assumes the connection is approved by ETE.
At a nominal 240 V AC output, the current corresponding to the 50 VA rating is approximately 0.21 A. This is a calculated value rather than a separately verified manufacturer current rating and assumes the connection is approved by ETE.
The MV50P2S2 has a specified 15% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should be selected with suitable voltage tolerance.
The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.
The transformer measures 75 × 65 × 88 mm (L × W × H) and weighs 1 kg. These details assist with electrical panel layout and mechanical installation planning.
The associated enclosure references are EPH 1 or EPN 1. The appropriate enclosure arrangement and its suitability for the installation should be confirmed before selection.
Before installation, confirm the correct 20/0/380/420 V primary connections, the 10/0/220/240 V secondary connection arrangement and the use of the 10 V adjustment tap with ETE. Check the connected load against the 50 VA rating and provide suitable circuit protection, wiring, mounting, ventilation and electrical clearances.
ETE MV multi-voltage control transformers provide a practical solution for industrial electrical applications requiring flexible primary connections and tapped secondary voltage arrangements. With 20/0/380/420 V primary terminals, 10/0/220/240 V secondary terminals, a 50 VA rating, Class E insulation and compact dimensions, the MV50P2S2 offers electrical panel builders, machinery manufacturers and maintenance engineers a versatile transformer option for compatible low-power control circuits.