ETE MV500P3S3 is a 500 VA single-phase multi-voltage industrial control transformer with dual 0/120 V primary windings and dual 0/12 V secondary windings. The primary windings support 120 V parallel or 240 V series connections, while the secondary windings provide 12 V AC parallel or 24 V AC series output. Class E insulation, 8% voltage regulation, dimensions of 120 x 120 x 120 mm, weight of 6.2 kg and EPH 3 or EPN 2 enclosure references.
£74.33
The ETE MV500P3S3 is a 500 VA single-phase multi-voltage industrial control transformer featuring dual primary windings and dual secondary windings. Part of the ETE MV stock control transformer range, this model provides flexible AC voltage conversion for compatible industrial control panels, OEM machinery and electrical automation systems.
The transformer has 0/120 V + 0/120 V primary terminals, allowing the two primary windings to be connected in parallel for a nominal 120 V AC supply or in series for a nominal 240 V AC supply. This dual-primary arrangement enables the same transformer model to be considered for compatible equipment using either primary voltage.
On the secondary side, the MV500P3S3 features 0/12 V + 0/12 V terminals. Its two nominal 12 V AC secondary windings can be connected in parallel to provide 12 V AC or in series to provide 24 V AC.
The combination of selectable 120 V / 240 V primary connections and 12 V / 24 V AC secondary configurations makes the MV500P3S3 particularly useful for control panel designs requiring flexibility across different AC supply and control voltage arrangements.
Rated at 500 VA, the transformer features Class E insulation and 8% voltage regulation. Its overall dimensions are 120 × 120 × 120 mm, with a specified weight of 6.2 kg. The associated enclosure references are EPH 3 or EPN 2.
The ETE MV500P3S3 is identified in the ETE Stock Control Transformer Range, March 2026.
The ETE MV500P3S3 incorporates two separate primary windings, each specified as 0/120 V. The windings can be configured in parallel or series to suit the intended nominal primary supply voltage.
For a nominal 120 V AC primary supply, the two primary windings are connected in parallel. In this configuration, both windings operate at the same nominal voltage and share the input current.
Correct winding polarity is essential when connecting primary windings in parallel. Incorrect connections can cause excessive circulating current and transformer damage.
For a nominal 240 V AC primary supply, the two primary windings are connected in series. When correctly connected, the applied voltage is distributed across the two nominal 120 V windings.
The windings must be connected with the correct polarity and terminal sequence according to the manufacturer's connection diagram. The 120 V and 240 V arrangements are alternative primary configurations, not independent simultaneous supply inputs.
The MV500P3S3 also incorporates two separate 0/12 V secondary windings, enabling a choice of nominal output voltage.
For a nominal 12 V AC output, the secondary windings are connected in parallel. The output voltage remains at 12 V AC, while the windings share the connected load within the overall transformer rating.
Correct polarity is critical. Incorrect parallel winding connections may cause excessive circulating current, overheating or damage.
For a nominal 24 V AC output, the secondary windings are connected in series. With the correct winding polarity, the two nominal 12 V outputs add together.
The secondary windings must be connected according to the ETE wiring diagram. The 12 V and 24 V options are alternative output configurations rather than two independent 500 VA outputs.
The ETE MV500P3S3 has a total rated apparent power of 500 VA. The nominal current corresponding to each voltage can be estimated using:
Current (A) = Apparent power (VA) ÷ Voltage (V)
These primary figures are idealised current calculations based on rated apparent power. Actual primary current depends on transformer losses, operating conditions and load characteristics.
These secondary figures represent the mathematical currents corresponding to the complete 500 VA rating. They are not separately confirmed manufacturer terminal ratings.
Electrical designers should verify the permissible winding and terminal currents, connected load, inrush requirements and suitable circuit protection before installation.
The ETE MV500P3S3 has a specified 8% voltage regulation. Voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under defined operating or test conditions.
The actual secondary voltage may vary with the primary supply and connected load. The nominal 12 V AC and 24 V AC outputs should therefore not be interpreted as electronically stabilised voltages.
Engineers should consider this characteristic when selecting the transformer for equipment with defined operating voltage tolerances.
Before installing the ETE MV500P3S3, confirm the intended primary supply voltage, required secondary output voltage, total connected apparent power and correct winding connections.
Primary wiring: Connect the two 0/120 V primary windings in parallel for nominal 120 V AC operation or in series for nominal 240 V AC operation, following the manufacturer's approved connection diagram.
Secondary wiring: Connect the two 0/12 V secondary windings in parallel for nominal 12 V AC output or in series for nominal 24 V AC output. Correct winding polarity is essential in both configurations.
Suitable primary and secondary circuit protection, conductor sizing, protective earthing where applicable, ventilation and secure mechanical mounting should be incorporated into the installation design.
The specified EPH 3 or EPN 2 enclosure references should be checked against the intended installation requirements. These references do not independently establish an enclosure protection rating or confirm that an enclosure is included.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 500 VA | |
|---|---|---|
| Primary Voltage | 0/120V + 0/120V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model / SKU | MV500P3S3 | |
| Product type | Industrial multi-voltage control transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 500 VA | |
| Primary terminals | 0/120 V + 0/120 V | |
| Primary winding arrangement | Two nominal 120 V windings | |
| Parallel primary configuration | 120 V AC | |
| Series primary configuration | 240 V AC | |
| Secondary terminals | 0/12 V + 0/12 V | |
| Secondary winding arrangement | Two nominal 12 V windings | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Output connection | 12 V parallel or 24 V series | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Calculated primary current at 120 V AC | Approximately 4.17 A, based on 500 VA | |
| Calculated primary current at 240 V AC | Approximately 2.08 A, based on 500 VA | |
| Calculated secondary current at 12 V AC | Approximately 41.67 A total, based on 500 VA | |
| Calculated secondary current at 24 V AC | Approximately 20.83 A, based on 500 VA | |
| Length | 120 mm | |
| Width | 120 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 120 × 120 mm | |
| Weight | 6.2 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV500P3S3 is a 500 VA single-phase multi-voltage control transformer intended for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. It supports nominal 120 V or 240 V primary configurations and 12 V or 24 V AC secondary outputs.
The primary terminals are specified as 0/120 V + 0/120 V, representing two separate nominal 120 V primary windings.
Yes. The two nominal 120 V primary windings can be connected in parallel for nominal 120 V AC operation, provided the correct winding polarity and manufacturer's connection instructions are followed.
Yes. The two nominal 120 V primary windings can be connected in series for nominal 240 V AC operation, following the manufacturer's approved wiring diagram.
The secondary terminals are specified as 0/12 V + 0/12 V, representing two separate nominal 12 V AC secondary windings.
Yes. The two secondary windings can be connected in parallel to provide a nominal 12 V AC output, using the correct winding polarity.
Yes. The two secondary windings can be connected in series to provide a nominal 24 V AC output, with the correct winding polarity so their voltages add together.
The ETE MV500P3S3 has a rated apparent power of 500 VA. This is the rating of the complete transformer rather than a separate rating for each winding.
At a nominal 12 V AC output, the 500 VA rating corresponds to approximately 41.67 A total when the secondary windings are correctly connected in parallel. This is a calculated value for load assessment.
At a nominal 24 V AC output, the 500 VA rating corresponds to approximately 20.83 A when the secondary windings are correctly connected in series. This is a calculated value for load assessment.
The MV500P3S3 has a specified Class E insulation system.
The ETE MV500P3S3 has a specified 8% voltage regulation. This should be considered when assessing the operating voltage requirements of connected equipment.
The transformer measures 120 mm long, 120 mm wide and 120 mm high, with a specified weight of 6.2 kg.
The specified enclosure references are EPH 3 or EPN 2. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
Correct winding polarity is essential when connecting primary or secondary windings in series or parallel. Incorrect connections can cause opposing voltages, excessive circulating current or transformer damage. Always follow the ETE connection diagram.
No. The ETE MV500P3S3 provides nominal 12 V AC or 24 V AC output, depending on the secondary configuration. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
When selecting the ETE MV500P3S3, first establish whether the intended primary supply is nominally 120 V AC or 240 V AC. The two primary windings must then be connected correctly in parallel or series using the manufacturer's wiring diagram.
Next, confirm whether the connected equipment requires 12 V AC or 24 V AC. The two secondary windings must be configured accordingly, with the correct winding polarity.
The transformer's 500 VA rating, 8% voltage regulation, Class E insulation, 120 × 120 × 120 mm dimensions and 6.2 kg weight should all be considered during electrical and mechanical design.
The ETE MV500P3S3 combines a 500 VA rating with dual 120 V primary windings and dual 12 V secondary windings. Its selectable 120 V / 240 V primary arrangements and 12 V / 24 V AC secondary outputs, together with Class E insulation and 8% voltage regulation, make it a versatile option for compatible industrial control panels, machinery and automation systems.