Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV500P2S2 is a 500 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, a 10/0/220/240 V tapped secondary requiring manufacturer-confirmed adjustment connections, Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure compatibility.
£74.33
The ETE MV500P2S2 is a 500 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring flexible AC voltage transformation. Part of the ETE MV multi-voltage control transformer range, this model features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a tapped output arrangement for compatible industrial control circuits.
The MV500P2S2 combines a substantial 500 VA apparent power rating with multiple primary and secondary winding connections. Its primary winding incorporates terminals marked 380 V and 420 V, while the secondary winding includes terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The exact output configuration and adjustment tap connections must be confirmed using ETE's approved wiring information before installation.
This multi-voltage arrangement makes the transformer particularly useful for electrical panel builders and machinery manufacturers working with industrial AC supplies and compatible higher-voltage control equipment. The tapped secondary winding provides flexibility when selecting an appropriate output connection, helping accommodate different control circuit requirements within one transformer model.
Featuring Class E insulation and 8% voltage regulation, the ETE MV500P2S2 provides defined electrical characteristics for transformer selection. Its dimensions of 120 × 120 × 120 mm and weight of 6.2 kg support integration into suitably designed industrial electrical cabinets. The specified compatible enclosure references are ETE EPH 3 or EPN 2.
The ETE MV500P2S2 provides a flexible solution for industrial electrical installations requiring a transformer with multiple primary and secondary connection options. Its 20/0/380/420 V primary winding and 10/0/220/240 V secondary winding make it suitable for applications where an industrial AC supply must be transformed to a compatible AC control voltage.
The primary winding incorporates terminals marked 380 V and 420 V, together with an additional 20 V terminal. These markings identify the available winding connections but do not independently establish every permissible supply voltage combination. The exact primary connection arrangement should be verified against ETE's approved wiring diagram before installation.
The secondary winding features terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The specified output arrangement is a tapped output according to the manufacturer's connection information. The 10 V terminal should not be assumed to provide an independent 10 V output, and the correct relationship between the secondary terminals must be confirmed with ETE.
At the total rated apparent power of 500 VA, the calculated current equivalents are approximately 2.27 A at 220 V and 2.08 A at 240 V. These figures are calculated by dividing the rated apparent power by the nominal voltage. They should not be interpreted as independently verified current ratings for every tapped connection arrangement. The permissible winding and tap loading limits should be checked before selecting the final connected load.
The specified 8% voltage regulation is relevant when designing industrial control circuits containing electromagnetic devices. Contactors, relays and solenoids may draw greater apparent power during energisation than during normal operation, potentially affecting the secondary voltage. Electrical designers should therefore assess both steady-state load and simultaneous switching requirements.
With Class E insulation, dimensions of 120 × 120 × 120 mm and a weight of 6.2 kg, the MV500P2S2 can be integrated into appropriately designed industrial electrical cabinets. Its specified EPH 3 or EPN 2 enclosure references provide compatible housing options where additional physical protection is required.
The MV500P2S2 provides AC voltage transformation rather than regulated DC output. Correct primary and secondary terminal selection, suitable circuit protection, conductor sizing, mechanical mounting, ventilation and protective earthing where applicable should be considered during installation. All adjustment tap connections must be verified against ETE's approved technical information before energising the transformer.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 500 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Manufacturer part number | MV500P2S2 | |
| Product family | MV Multi-Voltage Control Transformers | |
| Product category | Industrial Control Transformers | |
| Transformer configuration | Multi-tapped primary and secondary windings | |
| Number of phases | Single-phase | |
| Rated apparent power | 500 VA | |
| Primary terminal arrangement | 20/0/380/420 V | |
| Primary voltage terminal markings | 380 V and 420 V | |
| Primary additional terminal | 20 V | |
| Secondary terminal arrangement | 10/0/220/240 V | |
| Secondary voltage terminal markings | 220 V and 240 V | |
| Secondary adjustment tap | 10 V | |
| Secondary output connection | Tapped output according to the manufacturer's connection information | |
| Adjustment tap connection note | Confirm the correct 10 V adjustment tap and associated terminal connections with ETE. | |
| Calculated apparent-power current equivalent at 220 V secondary | Approximately 2.27 A | |
| Calculated apparent-power current equivalent at 240 V secondary | Approximately 2.08 A | |
| Calculated apparent-power current equivalent at 380 V primary | Approximately 1.32 A | |
| Calculated apparent-power current equivalent at 420 V primary | Approximately 1.19 A | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Length | 120 mm | |
| Width | 120 mm | |
| Height | 120 mm | |
| Overall dimensions (L × W × H) | 120 × 120 × 120 mm | |
| Weight | 6.2 kg | |
| Compatible enclosure references | EPH 3 or EPN 2 | |
| Typical installation | Industrial electrical control panels and machinery cabinets | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV500P2S2 is a 500 VA single-phase multi-voltage control transformer designed for industrial AC control circuits requiring a tapped primary and secondary winding arrangement.
The primary terminal markings are 20/0/380/420 V. The correct terminal combinations should be verified against ETE's approved connection information.
The secondary winding has terminals marked 10/0/220/240 V. The output is configured using the manufacturer's specified tapped connection arrangement.
The secondary includes terminals marked 220 V and 240 V. The exact nominal output available for a particular primary connection must be confirmed from ETE's wiring information.
The 10 V adjustment terminal provides an additional secondary winding connection. Its precise function and permitted use must be confirmed with ETE before installation.
This should not be assumed. The 10 V terminal forms part of the transformer's tapped winding arrangement, and its permitted connection method must be verified with ETE.
The transformer has primary terminals marked 380 V and 420 V, together with an additional 20 V terminal. The correct connection arrangement for a nominal 400 V AC supply must be confirmed with ETE rather than inferred from terminal markings alone.
The transformer has a rated apparent power of 500 VA. Connected equipment must remain within the applicable transformer and winding ratings.
At 500 VA and 220 V, the calculated current equivalent is approximately 2.27 A, assuming the total transformer rating applies to the approved output configuration.
At 500 VA and 240 V, the calculated current equivalent is approximately 2.08 A, assuming the total transformer rating applies to the approved output configuration.
The MV500P2S2 provides AC output. It does not incorporate a rectifier or regulated DC power supply.
The transformer has Class E insulation and a specified 8% voltage regulation.
The transformer measures 120 mm long × 120 mm wide × 120 mm high and weighs 6.2 kg.
The specified compatible enclosure references are ETE EPH 3 or EPN 2. Final enclosure selection should account for the installation environment, mounting requirements and ventilation.
Yes. Its 500 VA rating, multi-tapped windings and compact construction make it suitable for appropriately designed industrial control panels using compatible AC equipment.
The specified 8% voltage regulation describes secondary voltage variation under changing load conditions. Connected equipment should have suitable voltage tolerances for the intended application.
The correct primary and secondary wiring arrangements should be obtained from ETE or its approved technical documentation, particularly when using the 10 V adjustment tap.
The ETE MV500P2S2 combines a 500 VA rating with flexible primary connections and a tapped secondary winding incorporating 220 V and 240 V terminals. Its Class E insulation, 8% voltage regulation and compact construction make it a practical component for industrial electrical panel builders, machinery manufacturers and maintenance engineers requiring configurable AC control power.
We use cookies