ETE MV5000P2S2 is a 5000 VA single-phase multi-voltage industrial control transformer with 20/0/380/420 V primary terminals, 10/0/220/240 V tapped secondary terminals, Class F insulation and 3% voltage regulation for industrial machinery and electrical control panels.
£431.63
The ETE MV5000P2S2 is a robust and reliable 5000 VA single-phase multi-voltage control transformer designed to provide dependable voltage transformation and electrical isolation for industrial machinery, control panels and automation systems. As part of the ETE MV multi-voltage stock control transformer range, it is developed for electrical engineers, control panel builders and OEM machine manufacturers requiring a high-capacity transformer with flexible primary and secondary voltage connections.
The MV5000P2S2 features a 20/0/380/420 V primary terminal arrangement and 10/0/220/240 V secondary terminals, providing tapped voltage connections for industrial control and auxiliary power applications. The secondary terminal arrangement includes a 10 V adjustment tap, allowing the appropriate output configuration to be selected according to the manufacturer's connection instructions. The exact terminal connections must be confirmed with ETE before installation or energisation.
With a rated capacity of 5000 VA (5 kVA), Class F insulation and 3% voltage regulation, the MV5000P2S2 is well suited to demanding industrial control applications requiring substantial transformer capacity. Its dimensions of 245 × 220 × 230 mm, weight of 45 kg and associated EPN 6 enclosure reference make it suitable for integration into appropriately designed industrial electrical installations.
Industrial control transformers such as the ETE MV5000P2S2 convert incoming AC electrical supplies into secondary voltages suitable for industrial control equipment, machinery and auxiliary electrical circuits. By using separate primary and secondary windings, the transformer provides electrical isolation while allowing the secondary supply to be configured for compatible industrial equipment.
The MV5000P2S2 incorporates 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals. This multi-voltage arrangement provides flexibility when integrating the transformer into installations requiring nominal 220 V or 240 V AC control supplies. The 10 V secondary adjustment tap forms part of the manufacturer's tapped output configuration, and the correct connections must be confirmed with ETE before the transformer is energised.
Its substantial 5000 VA rated capacity makes the transformer suitable for higher-demand industrial control circuits and installations with multiple connected devices. The 3% voltage regulation helps limit changes in secondary voltage between no-load and rated-load conditions, supporting consistent operation of compatible control equipment. Connected loads must be assessed for their combined apparent power and starting requirements to ensure operation within the transformer's specified capacity.
The MV5000P2S2 uses Class F insulation, providing a thermal insulation classification appropriate for demanding industrial electrical applications. Its robust 45 kg construction requires secure mechanical support and appropriate mounting arrangements. The manufacturer's EPN 6 enclosure reference identifies the associated enclosure option, while the installation must provide suitable ventilation, electrical protection, earthing and access for maintenance.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 5000 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | MV Multi-Voltage Stock Control Transformers | |
| Model | MV5000P2S2 | |
| Product type | Multi-voltage industrial control transformer | |
| Transformer type | Single-phase | |
| Rated apparent power | 5000 VA (5 kVA) | |
| Primary terminal markings | 20/0/380/420 V | |
| Primary voltage taps | 380 V and 420 V AC nominal | |
| Primary adjustment terminal | 20 V tap | |
| Secondary terminal markings | 10/0/220/240 V | |
| Secondary voltage taps | 220 V and 240 V AC nominal | |
| Secondary adjustment terminal | 10 V tap; confirm connections with ETE | |
| Output connection | Tapped output per manufacturer's datasheet | |
| Insulation class | F | |
| Voltage regulation | 3% | |
| Mounting type | Industrial electrical panel / chassis installation | |
| Length | 245 mm | |
| Width | 220 mm | |
| Height | 230 mm | |
| Dimensions (L × W × H) | 245 × 220 × 230 mm | |
| Weight | 45 kg | |
| Enclosure reference | EPN 6 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV5000P2S2 is a 5000 VA single-phase multi-voltage control transformer designed to provide electrical isolation and tapped secondary voltage connections for industrial machinery, control panels, automation systems and auxiliary AC power circuits.
The transformer has a rated apparent power of 5000 VA (5 kVA), making it suitable for higher-capacity industrial control applications when connected loads remain within the manufacturer's specified operating limits.
The transformer features primary terminals marked 20/0/380/420 V, including nominal 380 V and 420 V AC connections and a 20 V primary terminal provision. The correct primary connections should follow ETE's instructions.
The MV5000P2S2 has secondary terminals marked 10/0/220/240 V, providing tapped output connections associated with nominal 220 V and 240 V AC supplies. The exact output configuration must follow the manufacturer's datasheet.
The 10 V adjustment tap is part of the transformer's secondary terminal arrangement and provides an additional connection option within the tapped output configuration. The correct terminal connections must be confirmed with ETE before installation or energisation.
The transformer has Class F insulation, which is designed to withstand higher winding temperatures than lower thermal insulation classes when operated within the manufacturer's specified limits.
The ETE MV5000P2S2 has a specified 3% voltage regulation, helping maintain a consistent secondary voltage as the connected load changes between no-load and rated-load conditions.
The transformer measures 245 × 220 × 230 mm (length × width × height) and weighs 45 kg. Suitable mechanical support and mounting arrangements are required for safe installation.
The manufacturer's associated enclosure reference is EPN 6. The installation should provide suitable electrical protection, ventilation, mechanical support and adequate space for wiring and maintenance.
Yes. The 5000 VA rated capacity allows the transformer to supply multiple compatible industrial control devices, provided their combined apparent power, starting demands and operating conditions remain within the transformer's permitted limits.
ETE MV multi-voltage control transformers provide dependable voltage transformation for industrial machinery, automation systems and electrical control panels. Combining 5000 VA capacity, flexible 220 V and 240 V tapped secondary connections, Class F insulation and 3% voltage regulation, the ETE MV5000P2S2 offers a robust solution for demanding industrial control and auxiliary power applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.