Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV400P2S2 is a 400 VA single-phase multi-voltage control transformer featuring 20/0/380/420 V primary terminals, 10/0/220/240 V tapped secondary terminals, Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure references.
£63.98
The ETE MV400P2S2 is a 400 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring a lower-voltage AC control supply. Part of the ETE MV Multi-Voltage Series, it features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a flexible tapped voltage arrangement for industrial control applications.
The transformer is suitable for electrical systems using the manufacturer's specified primary voltage connections, with secondary terminals marked for nominal 220 V and 240 V AC control supplies. Its tapped winding configuration allows electrical panel builders and equipment manufacturers to accommodate different voltage requirements, subject to the approved ETE connection diagram.
With a 400 VA rated apparent power, Class E insulation and 8% voltage regulation, the MV400P2S2 is suitable for appropriately rated industrial control circuits. It measures 120 × 108 × 120 mm, weighs 5.5 kg and has specified enclosure references of EPH 3 or EPN 2.
Important connection note: The secondary terminal arrangement incorporates a 10 V adjustment tap. The exact terminal connections and adjustment method must be confirmed with ETE before installation or energisation.
The ETE MV400P2S2 incorporates a 20/0/380/420 V primary terminal arrangement, providing connection flexibility for industrial control systems using the manufacturer's specified supply configurations.
The terminals marked 380 V and 420 V support corresponding nominal industrial AC supply arrangements when wired according to the approved ETE connection diagram. The additional 20 V primary terminal forms part of the winding arrangement and must not be interpreted independently of the manufacturer's instructions.
This multi-voltage design is useful for electrical panel builders and OEM machinery manufacturers working with equipment requiring different primary voltage connections.
Installation requirement: Verify the available supply voltage, selected primary terminals and corresponding secondary output arrangement before energising the transformer. Incorrect connections can result in unintended secondary voltages or equipment damage.
The MV400P2S2 features 10/0/220/240 V secondary terminals, providing a tapped secondary arrangement for industrial control circuits.
The manufacturer's specification identifies the output connection as tapped output per datasheet. Consequently, the exact terminal combinations required for each nominal secondary voltage must be established using ETE's approved wiring documentation.
For a nominal 220 V AC output, the transformer's 400 VA rating corresponds to a calculated secondary current of approximately 1.82 A, assuming the full apparent power rating is available at the selected output connection.
This voltage is suitable for compatible industrial control devices, including appropriately rated contactors, relays and machinery switching circuits.
For a nominal 240 V AC output, the 400 VA rating corresponds to a calculated secondary current of approximately 1.67 A, assuming the full rating applies to that connection.
Electrical designers should verify the permitted terminal arrangement, connected load and voltage tolerances of the control equipment before commissioning.
The additional 10 V secondary terminal provides an adjustment feature within the transformer's tapped winding arrangement.
Manufacturer confirmation required: Confirm the exact 10 V adjustment tap connections with ETE. The terminal markings alone do not establish how the adjustment terminal should be combined with the other winding connections, and an unverified connection method must not be assumed.
The MV400P2S2 has a specified 8% voltage regulation characteristic. Voltage regulation describes the change in secondary voltage as the electrical load varies under the relevant operating conditions.
This characteristic should be considered when selecting voltage-sensitive control equipment, particularly contactors, relays and switching devices that may impose short-duration inrush loads.
The 400 VA rating represents the transformer's rated apparent power. It does not independently establish the permissible loading of every individual tap or winding section. The manufacturer's connection and loading requirements should be followed.
The ETE MV400P2S2 measures 120 mm in length, 108 mm in width and 120 mm in height, with a specified weight of 5.5 kg. These dimensions help electrical panel builders assess available cabinet space and mounting support requirements.
The transformer has Class E insulation, and ETE specifies EPH 3 or EPN 2 as the corresponding enclosure references. The final enclosure and mounting arrangement should provide appropriate mechanical support, ventilation and environmental protection.
Suitable primary and secondary circuit protection, conductor sizing, protective earthing and terminal connections should be incorporated into the electrical installation. All winding connections must be verified using the manufacturer's approved diagram.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 400 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Manufacturer part number | MV400P2S2 | |
| Product series | MV Multi-Voltage Series | |
| Product category | Control Transformers | |
| Transformer type | Multi-voltage control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 400 VA | |
| Primary terminals | 20/0/380/420 V | |
| Primary voltage markings | 380 V and 420 V, with an additional 20 V terminal | |
| Secondary terminals | 10/0/220/240 V | |
| Secondary voltage markings | 220 V and 240 V, with an additional 10 V terminal | |
| Output connection | Tapped output per datasheet | |
| Adjustment tap | 10 V — confirm terminal connections with ETE | |
| Calculated secondary current at 220 V | Approximately 1.82 A, assuming the full 400 VA rating applies to the selected connection | |
| Calculated secondary current at 240 V | Approximately 1.67 A, assuming the full 400 VA rating applies to the selected connection | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Length | 120 mm | |
| Width | 108 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 108 × 120 mm | |
| Weight | 5.5 kg | |
| Enclosure references | EPH 3 or EPN 2 | |
| Manufacturer catalogue | ETE Stock Control Transformer Range | |
| Catalogue date | March 2026 |
The ETE MV400P2S2 is a 400 VA single-phase multi-voltage control transformer designed for industrial control panels, electrical machinery and automation systems requiring tapped AC control voltage connections.
The transformer features 20/0/380/420 V primary terminals. The correct connections must be selected according to ETE's approved wiring diagram and the available supply voltage.
The transformer has 10/0/220/240 V secondary terminals, with a tapped output arrangement specified by ETE. The exact connections for the required output voltage must be confirmed using the manufacturer's datasheet.
At 400 VA, the calculated current is approximately 1.82 A at 220 V AC or 1.67 A at 240 V AC, assuming the full rating is available at the selected output connection.
The 10 V adjustment tap must be connected according to ETE's approved terminal diagram. Its exact connection method should be confirmed with ETE before installation or energisation.
The transformer measures 120 × 108 × 120 mm, weighs 5.5 kg and has Class E insulation with 8% voltage regulation.
The manufacturer's specified enclosure references are EPH 3 or EPN 2. The final installation should provide suitable mounting support, ventilation and electrical protection.
The ETE MV400P2S2 combines a 400 VA rating, 20/0/380/420 V primary terminals and 10/0/220/240 V tapped secondary terminals in a compact industrial control transformer. With Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure options, it provides a flexible solution for electrical panel builders, OEM machinery manufacturers and industrial maintenance engineers. Confirm the 10 V adjustment tap and all permitted voltage connections with ETE before commissioning.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.