ETE MV400P2S1 is a 400 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary taps, Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure references.
£63.98
The ETE MV400P2S1 is a 400 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring a nominal 55 V AC or 110 V AC control supply. Part of the ETE MV Multi-Voltage Series, it features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, providing flexible voltage connections for industrial control applications.
The transformer is suited to installations where a higher-voltage AC supply must be converted to a lower-voltage control circuit supply. Its multi-tapped primary arrangement includes 380 V and 420 V terminal markings, while its secondary winding provides selectable 55 V and 110 V output taps. The precise primary connections must be selected using the manufacturer's approved wiring instructions.
With a 400 VA rated capacity, Class E insulation and 8% voltage regulation, the MV400P2S1 provides a practical solution for appropriately rated control equipment. It measures 120 × 108 × 120 mm, weighs 5.5 kg and has specified enclosure references of EPH 3 or EPN 2.
Important connection note: The primary winding includes a 20 V adjustment tap. The exact terminal connections and adjustment method must be confirmed with ETE before installation or energisation.
The ETE MV400P2S1 features a 20/0/380/420 V primary terminal arrangement, allowing connection to the industrial AC supply configurations specified by ETE. The primary winding includes terminals marked for nominal 380 V and 420 V arrangements, together with an additional 20 V terminal.
This flexibility is useful for panel builders and machinery manufacturers designing electrical control equipment for different supply voltage requirements. The correct connection must be selected according to the available supply and the manufacturer's approved terminal diagram.
The 20 V primary adjustment tap provides an additional connection feature, but the exact adjustment method must not be inferred solely from the terminal markings.
Installation requirement: Confirm the correct primary connections, including the 20 V adjustment tap, with ETE before energising the transformer. Incorrect connections can result in unintended secondary voltages or transformer damage.
The MV400P2S1 incorporates 0/55/110 V secondary terminals, providing two nominal secondary voltage options for compatible industrial control circuits.
When the full secondary winding is connected for a nominal 110 V AC output, the transformer's 400 VA rating corresponds to a calculated output current of approximately 3.64 A.
This arrangement is suitable for appropriately rated 110 V AC control equipment, including contactor coils, relays, switching circuits and machinery control devices.
The intermediate secondary terminal provides a nominal 55 V AC output connection. This is useful where compatible industrial control equipment requires a lower AC control voltage.
Dividing the total transformer rating by 55 V produces a theoretical current of approximately 7.27 A. However, this calculation does not establish the permissible current or apparent power available from the individual 55 V winding section.
Engineering consideration: Confirm the permissible 55 V tap loading with ETE before designing a circuit around the theoretical current. The transformer rating must not be assumed to apply independently to every tap.
The MV400P2S1 has a specified 8% voltage regulation characteristic. Voltage regulation describes the variation in secondary voltage as transformer loading changes under the relevant operating conditions.
This characteristic should be considered when selecting voltage-sensitive industrial control devices, particularly contactors and relays that may experience short-duration switching inrush currents.
For correct transformer selection, engineers should consider the total connected apparent power, expected operating load, starting or energisation demands and the permissible voltage range of the connected equipment.
The ETE MV400P2S1 measures 120 mm in length, 108 mm in width and 120 mm in height, with a specified weight of 5.5 kg. These dimensions allow electrical panel builders to plan mounting space and mechanical support within appropriately designed control cabinets.
The transformer has Class E insulation, and the manufacturer's specified enclosure references are EPH 3 or EPN 2. The enclosure and mounting arrangement should be selected to provide suitable ventilation, mechanical protection and accessibility for the intended installation.
Primary and secondary circuit protection, conductor sizing, protective earthing and terminal connections should be designed in accordance with the applicable electrical installation requirements and ETE's technical instructions.
The manufacturer's approved connection diagram should be used to verify the primary adjustment tap and secondary voltage selection before commissioning.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 400 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Manufacturer part number | MV400P2S1 | |
| Product series | MV Multi-Voltage Series | |
| Product category | Control Transformers | |
| Transformer type | Multi-voltage control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 400 VA | |
| Primary terminals | 20/0/380/420 V | |
| Primary adjustment tap | 20 V — confirm connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary output connections | 55 V AC or 110 V AC taps | |
| Calculated secondary current at 110 V | Approximately 3.64 A at 400 VA | |
| 55 V tap current | Permissible loading requires manufacturer confirmation | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Length | 120 mm | |
| Width | 108 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 108 × 120 mm | |
| Weight | 5.5 kg | |
| Enclosure references | EPH 3 or EPN 2 | |
| Manufacturer catalogue | ETE Stock Control Transformer Range | |
| Catalogue date | March 2026 |
The ETE MV400P2S1 is a 400 VA single-phase multi-voltage control transformer designed to supply compatible industrial control circuits requiring nominal 55 V AC or 110 V AC. Typical applications include machinery control panels, contactors, relays and automation equipment.
The transformer features 20/0/380/420 V primary terminals, including a 20 V adjustment tap. The correct connections must be confirmed with ETE and selected according to the manufacturer's approved wiring diagram.
Yes. The transformer has 0/55/110 V secondary terminals, providing nominal 55 V AC and 110 V AC output connections. The permissible loading of the 55 V tap must be confirmed with ETE.
At the full 400 VA rating, the calculated nominal secondary current is approximately 3.64 A at 110 V AC. The connected load and any switching inrush requirements should also be considered.
Not without manufacturer confirmation. The 400 VA rating applies to the transformer but does not independently establish the permissible current or apparent power available from the individual 55 V winding section. Confirm the tap loading limits with ETE.
The 20 V primary adjustment tap forms part of the transformer's multi-voltage winding arrangement. Its exact function and terminal connections must be confirmed with ETE before installation or energisation.
The transformer measures 120 × 108 × 120 mm, weighs 5.5 kg, has Class E insulation and 8% voltage regulation, and has specified enclosure references of EPH 3 or EPN 2.
The ETE MV400P2S1 combines a 400 VA rating, 20/0/380/420 V primary terminals and selectable 55 V or 110 V secondary connections in a compact industrial control transformer. With Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure options, it provides a flexible solution for electrical panel builders, OEM machinery manufacturers and industrial maintenance engineers. Confirm the 20 V primary adjustment tap connections and permissible secondary tap loading with ETE before commissioning.