ETE MV400P1S3 is a 400 VA single-phase multi-voltage industrial control transformer with 10/0/220/240 V primary terminals and dual 0/12 V secondary windings. Its secondary output can be configured for 12 V AC in parallel or 24 V AC in series. The 10 V primary adjustment tap connections must be confirmed with ETE. Class E insulation, 8% voltage regulation, dimensions of 120 x 108 x 120 mm, weight of 5.5 kg and EPH 3 or EPN 2 enclosure references.
£63.98
The ETE MV400P1S3 is a 400 VA single-phase multi-voltage industrial control transformer featuring a tapped primary winding and two nominal 12 V AC secondary windings. Part of the ETE MV stock control transformer range, this model provides flexible low-voltage AC control power for compatible industrial electrical panels, OEM machinery and automation equipment.
The transformer features 10/0/220/240 V primary terminals and 0/12 V + 0/12 V secondary terminals. Its secondary windings can be connected in parallel for a nominal 12 V AC output or in series for a nominal 24 V AC output, allowing the same transformer to accommodate different control circuit voltage requirements.
The MV400P1S3 incorporates a 10 V primary adjustment tap. The exact function of this tap and its approved terminal connections must be confirmed with ETE before installation. The primary terminal markings should not be used alone to infer a wiring configuration.
Rated at 400 VA, the MV400P1S3 features Class E insulation and 8% voltage regulation. It measures 120 × 108 × 120 mm and weighs 5.5 kg, with enclosure references of EPH 3 or EPN 2.
This model is identified as MV400P1S3 in the ETE Stock Control Transformer Range, March 2026.
The ETE MV400P1S3 has a tapped primary winding with terminals marked 10/0/220/240 V. This arrangement is intended for compatible AC supply configurations using the appropriate manufacturer-approved connections.
The 10 V primary adjustment tap is part of the primary winding arrangement. Its exact purpose and approved terminal combinations must be confirmed with ETE before the transformer is energised. The 10 V marking must not be treated as evidence of an independently rated 10 V primary input.
Incorrect primary connections may result in an unsuitable secondary voltage, excessive winding current or equipment damage. The available supply voltage and intended terminal arrangement should therefore be verified against the ETE wiring diagram.
The MV400P1S3 incorporates two separate 0/12 V secondary windings. These can be configured to provide either a nominal 12 V AC or 24 V AC output.
When the two secondary windings are correctly connected in parallel, the nominal output voltage remains at 12 V AC. Parallel operation allows the windings to share the connected load within the transformer's overall rating.
Correct winding polarity is essential. An incorrect parallel connection can create excessive circulating current, potentially causing overheating or transformer damage. The approved ETE connection diagram must be followed.
When the two secondary windings are correctly connected in series, their nominal voltages add together to provide 24 V AC.
The series connection must use the correct winding polarity so the two 12 V outputs add rather than oppose one another. The manufacturer's terminal identification and wiring instructions should be used to establish the correct connection.
The 12 V and 24 V options are alternative configurations of the same transformer, not two independent 400 VA outputs.
The ETE MV400P1S3 has a total rated apparent power of 400 VA. The current corresponding to each nominal secondary voltage can be calculated using:
Current (A) = Apparent power (VA) ÷ Secondary voltage (V)
For a correctly connected 12 V AC parallel output:
400 VA ÷ 12 V = approximately 33.33 A
This represents the calculated total current corresponding to the complete transformer rating at 12 V AC. It is not a separately confirmed manufacturer terminal current rating.
For a correctly connected 24 V AC series output:
400 VA ÷ 24 V = approximately 16.67 A
This represents the calculated current corresponding to the complete transformer rating at 24 V AC.
The connected load must remain within the applicable transformer and winding ratings. Load characteristics, starting current, inrush demand and protective device selection should also be considered during electrical design.
The ETE MV400P1S3 has a specified 8% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under defined operating or test conditions.
The actual secondary voltage may vary with primary supply conditions and the connected load. The nominal 12 V AC and 24 V AC outputs should therefore not be interpreted as electronically stabilised voltages.
For equipment with defined voltage tolerances, engineers should assess the transformer's regulation characteristic alongside expected primary supply variation.
Before installing the ETE MV400P1S3, verify the available primary supply, required secondary voltage, connected load and correct terminal connections.
Primary wiring: The 10/0/220/240 V terminals include a 10 V adjustment tap. Confirm the approved terminal connections with ETE before energising the transformer.
Secondary wiring: The two 0/12 V secondary windings must be connected in parallel for a nominal 12 V AC output or in series for a nominal 24 V AC output. Correct winding polarity is essential in both configurations.
Suitable primary and secondary circuit protection, conductor sizing, protective earthing where applicable, ventilation and secure mechanical mounting should be incorporated into the installation design.
The specified EPH 3 or EPN 2 enclosure references should be checked against the intended installation requirements. An enclosure reference alone does not confirm that an enclosure is included or establish the protection rating of a completed assembly.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 400 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model / SKU | MV400P1S3 | |
| Product type | Industrial multi-voltage control transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 400 VA | |
| Primary terminals | 10/0/220/240 V | |
| Primary adjustment tap | 10 V | |
| Primary connection note | Confirm connections with ETE | |
| Secondary terminals | 0/12 V + 0/12 V | |
| Secondary winding arrangement | Two nominal 12 V AC windings | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Output connection | 12 V parallel or 24 V series | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Calculated current at nominal 12 V AC | Approximately 33.33 A total, based on 400 VA | |
| Calculated current at nominal 24 V AC | Approximately 16.67 A, based on 400 VA | |
| Length | 120 mm | |
| Width | 108 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 108 × 120 mm | |
| Weight | 5.5 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV400P1S3 is a 400 VA single-phase multi-voltage control transformer intended for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. Its dual secondary windings provide selectable 12 V AC or 24 V AC output configurations.
The primary terminals are specified as 10/0/220/240 V. The correct connections, including the 10 V adjustment tap, must be confirmed with ETE.
The MV400P1S3 includes a 10 V primary adjustment tap as part of its tapped primary winding. Its exact function and approved terminal connections must be confirmed with ETE before installation.
The secondary terminals are specified as 0/12 V + 0/12 V, representing two separate nominal 12 V AC secondary windings.
Yes. The two secondary windings can be connected in parallel to provide a nominal 12 V AC output, provided the correct winding polarity and manufacturer's wiring instructions are followed.
Yes. The two secondary windings can be connected in series to provide a nominal 24 V AC output, with the correct winding polarity so their voltages add together.
The ETE MV400P1S3 has a rated apparent power of 400 VA. This rating applies to the complete transformer rather than separately to each secondary winding.
At a nominal 12 V AC output, the 400 VA rating corresponds to approximately 33.33 A total when the secondary windings are correctly connected in parallel. This is a calculated value for load assessment.
At a nominal 24 V AC output, the 400 VA rating corresponds to approximately 16.67 A when the secondary windings are correctly connected in series. This is a calculated value for load assessment.
The MV400P1S3 has a specified Class E insulation system.
The ETE MV400P1S3 has a specified 8% voltage regulation. This should be considered when assessing the operating voltage requirements of connected equipment.
The transformer measures 120 mm long, 108 mm wide and 120 mm high, with a specified weight of 5.5 kg.
The specified enclosure references are EPH 3 or EPN 2. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
Correct winding polarity is essential when connecting the two 12 V secondary windings in series or parallel. Incorrect connections can cause opposing voltages, excessive circulating current or transformer damage. Always follow the ETE connection diagram.
No. The ETE MV400P1S3 provides a nominal 12 V AC or 24 V AC output, depending on the secondary winding configuration. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
The MV400P1S3 has a 10/0/220/240 V primary terminal arrangement incorporating a 10 V adjustment tap. Confirming the ETE connection diagram helps prevent incorrect wiring and ensures the intended primary configuration is selected.
When selecting the ETE MV400P1S3, verify that the intended primary supply can be accommodated using the manufacturer's approved terminal arrangement. The 10 V primary adjustment tap must be connected only in accordance with ETE's instructions.
Next, determine whether the connected equipment requires a nominal 12 V AC or 24 V AC supply. The two secondary windings must be configured correctly in parallel or series, with the appropriate polarity.
The transformer's 400 VA rating, 8% voltage regulation, Class E insulation, 120 × 108 × 120 mm dimensions and 5.5 kg weight should all be considered during electrical and mechanical design.
The ETE MV400P1S3 combines a 400 VA rating with a tapped 10/0/220/240 V primary and dual 12 V secondary windings. Its selectable 12 V AC parallel or 24 V AC series output, Class E insulation and 8% voltage regulation make it a practical option for compatible industrial control panels and OEM machinery. Always confirm the 10 V primary adjustment tap connections with ETE.