ETE MV4000P2S1 is a 4000 VA (4 kVA) single-phase multi-voltage industrial control transformer with 20/0/380/420 V primary terminals, 0/55/110 V secondary terminals for 55 V or 110 V output connections, Class F insulation, 3% voltage regulation and EPN 6 enclosure compatibility.
£367.58
The ETE MV4000P2S1 is a robust and reliable 4,000 VA (4 kVA) single-phase multi-voltage control transformer designed to provide dependable voltage transformation for industrial control panels, machinery and electrical automation systems. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the ETE MV multi-voltage transformer series, developed for panel builders, OEM manufacturers and industrial electrical engineers requiring flexible primary and secondary voltage connections.
Designed for continuous-duty control circuit applications, the MV4000P2S1 features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, allowing suitable 55 V or 110 V output connections according to the required wiring arrangement. Its multi-voltage configuration makes it particularly useful in industrial installations where control equipment requires a lower operating voltage than the available supply.
With a rated capacity of 4,000 VA, Class F insulation and 3% voltage regulation, the ETE MV4000P2S1 provides dependable performance for demanding electrical control applications. Its open-frame construction, IP20 touch-proof terminals and core earth connection support practical installation within suitable electrical enclosures. Measuring 245 × 190 × 230 mm and weighing 36 kg, the transformer is suitable for secure mounting in industrial control cabinets, with EPN 6 identified as the compatible enclosure reference.
The ETE MV4000P2S1 multi-voltage transformer uses electromagnetic induction to transform a suitable single-phase AC supply into a lower secondary voltage for industrial control equipment. Its 4 kVA continuous rating provides capacity for appropriately designed control circuits, while the multi-tap winding arrangement allows flexibility when selecting the required operating voltage.
The primary winding provides terminals marked 20/0/380/420 V, while the secondary provides terminals marked 0/55/110 V. Depending on the connection arrangement, the secondary can provide a 55 V or 110 V output. The 20 V primary adjustment tap must be connected only in accordance with the manufacturer's wiring information, and the correct connections should be confirmed with ETE before energising the transformer.
The transformer incorporates Class F insulation, Class H varnish impregnation and a core earth connection to support reliable operation in industrial environments. Its 3% voltage regulation helps maintain consistent output performance as the connected load varies. The open-frame design is intended for installation within a suitably protected electrical cabinet or enclosure rather than unrestricted exposure to the surrounding environment.
For installations requiring an enclosed arrangement, ETE EPN 6 is the specified compatible enclosure reference. The transformer's mounting, ventilation, overcurrent protection and primary and secondary connections should be selected by a competent electrical installer in accordance with the applicable installation requirements and ETE technical documentation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 4000 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Brand | ETE | |
| Series | MV Multi-Voltage Control Transformers | |
| Model | MV4000P2S1 | |
| Product type | Multi-voltage control circuit transformer | |
| Transformer type | Single-phase | |
| Rated apparent power | 4,000 VA (4 kVA) | |
| Duty rating | Continuous | |
| Primary terminal markings | 20/0/380/420 V | |
| Secondary terminal markings | 0/55/110 V | |
| Secondary output connections | 55 V or 110 V | |
| Primary adjustment tap | 20 V; confirm connection arrangement with ETE | |
| Rated frequency | 50/60 Hz | |
| Insulation class | Class F | |
| Voltage regulation | 3% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding impregnation | Class H varnish | |
| Earthing provision | Core earth connection | |
| Ambient temperature range | −10 °C to +35 °C | |
| Design standard | EN 61558-1 | |
| Construction | Open-frame transformer | |
| Mounting type | Fixed mounting within a suitable electrical enclosure | |
| Length | 245 mm | |
| Width | 190 mm | |
| Height | 230 mm | |
| Dimensions (L × W × H) | 245 × 190 × 230 mm | |
| Weight | 36 kg | |
| Compatible enclosure reference | EPN 6 | |
| Manufacturer range | ETE Stock Control Transformer Range | |
| Product reference | MV4000P2S1 |
The ETE MV4000P2S1 is a single-phase multi-voltage control transformer used to supply lower-voltage AC power to industrial control circuits, automation equipment and electrical machinery. It is suitable for applications requiring a transformer with a 4,000 VA continuous rating and appropriate 55 V or 110 V secondary connections.
The transformer has a rated apparent power of 4,000 VA (4 kVA) and is designed for continuous-duty control circuit applications. The connected load must remain within the transformer's rated capacity and the limits of the selected secondary connection.
The MV4000P2S1 has primary terminals marked 20/0/380/420 V. These provide the manufacturer's multi-voltage primary connection arrangement, including a 20 V adjustment tap. The correct wiring configuration must be confirmed with ETE before installation.
The transformer has secondary terminals marked 0/55/110 V, providing connection options for 55 V or 110 V AC applications. The correct secondary terminals must be selected for the required output voltage and connected equipment.
The 20 V primary adjustment tap forms part of the transformer's multi-voltage primary winding arrangement. Its correct use depends on the required supply connection. Confirm the appropriate primary terminal connections with ETE before wiring or energising the transformer.
The ETE MV4000P2S1 uses Class F insulation and Class H varnish impregnation. These features support reliable electrical insulation and winding protection during continuous industrial operation.
The transformer has a specified 3% voltage regulation, helping to limit changes in secondary output voltage between no-load and rated-load operating conditions.
The transformer measures 245 mm long × 190 mm wide × 230 mm high and weighs 36 kg. These dimensions should be considered when designing the mounting arrangement and selecting an appropriate electrical enclosure.
The specified compatible enclosure reference is ETE EPN 6. The transformer has an open-frame construction with IP20 touch-proof terminals and should be installed in a suitable enclosure providing the necessary environmental protection, ventilation and mechanical support.
Yes. The ETE MV4000P2S1 is designed as a continuous-rated control circuit transformer. It is suitable for continuous industrial operation when correctly installed, protected and operated within its specified electrical and ambient temperature limits.
ETE MV multi-voltage control transformers are designed to provide dependable voltage transformation for industrial control panels, OEM machinery and electrical automation installations. With its 4,000 VA continuous rating, flexible primary and secondary terminal arrangements, Class F insulation and robust construction, the ETE MV4000P2S1 offers a practical solution for reliable industrial control circuit power supplies.