ETE MV300P2S1 is a 300 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary taps, Class E insulation and 8% voltage regulation for industrial control circuits.
£54.90
The ETE MV300P2S1 is a 300 VA single-phase multi-voltage control transformer designed for industrial electrical panels, machinery control systems and automation equipment requiring a nominal 55 V AC or 110 V AC secondary supply. Manufactured by Eastern Transformers & Equipment (ETE), this model belongs to the MV Multi-Voltage Series and provides flexible primary and secondary voltage connections for industrial applications.
Featuring 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, the MV300P2S1 accommodates the manufacturer's specified primary supply configurations and offers selectable 55 V or 110 V output taps. The secondary winding also provides a centre-tapped arrangement suitable for appropriately designed industrial control circuits.
With a 300 VA rated capacity, Class E insulation and 8% voltage regulation, this transformer is suitable for appropriately sized industrial control loads. It measures 120 × 100 × 120 mm, weighs 4.7 kg and has specified enclosure references of EPH 3 or EPN 2.
Important: The primary terminal arrangement incorporates a 20 V adjustment tap. Confirm the exact adjustment tap connections with ETE before installation or energisation.
The ETE MV300P2S1 features a 20/0/380/420 V primary terminal arrangement intended for the manufacturer's specified industrial AC supply configurations. This makes it useful for electrical panel builders working with machinery and control systems designed around nominal 380 V or 420 V primary connections.
The primary winding also incorporates a 20 V adjustment tap. The precise relationship between the adjustment terminal and the other primary connections must be established using ETE's approved wiring diagram. The terminal markings alone should not be used to infer an unverified voltage correction method.
Installation requirement: Confirm the correct primary connections, including the 20 V adjustment tap, with ETE before energising the transformer. Incorrect connections may result in unintended secondary voltages, excessive winding excitation or equipment damage.
The MV300P2S1 incorporates 0/55/110 V secondary terminals, allowing the installer to select a nominal 55 V AC or 110 V AC connection according to the required control circuit voltage.
Using the full 110 V secondary winding, the 300 VA rating corresponds to a calculated nominal output current of approximately 2.73 A. This configuration is suited to appropriately rated 110 V AC control circuits, including industrial contactors, relays and switching equipment.
The intermediate secondary terminal provides a nominal 55 V AC connection. This can be useful for compatible low-voltage AC control equipment and centre-tapped control circuit arrangements.
Although dividing 300 VA by 55 V gives a theoretical current of approximately 5.45 A, this does not establish the permissible loading of the 55 V tap. The manufacturer must confirm the allowable half-winding current and any simultaneous loading restrictions before the circuit is designed.
The specified 8% voltage regulation should be considered when selecting voltage-sensitive devices, particularly where contactor inrush currents or changing control loads may affect the secondary voltage.
The ETE MV300P2S1 has dimensions of 120 mm length × 100 mm width × 120 mm height and weighs 4.7 kg. Its construction is intended for installation in appropriately designed electrical panels and machinery control cabinets.
The ETE MV range incorporates IP20 touch-proof terminals, Class H varnish impregnation and a protective core earth connection. The range is designed to EN 61558-1 for continuous-rated control circuit operation, with an ambient temperature range of −10 to +35 °C. The MV300P2S1 has Class E insulation.
For this 300 VA model, ETE specifies enclosure references EPH 3 or EPN 2. The installation should provide adequate mounting support, ventilation, appropriate primary and secondary circuit protection, conductor sizing and protective earthing.
Transformer selection should account for both steady-state load and any short-duration inrush requirements of connected control equipment. The manufacturer's terminal diagram must be followed for the primary adjustment tap and secondary voltage selection.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 300 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Manufacturer part number | MV300P2S1 | |
| Product series | MV Multi-Voltage Series | |
| Product type | Multi-voltage control circuit transformer | |
| Rated apparent power | 300 VA | |
| Number of phases | Single-phase | |
| Primary terminals | 20/0/380/420 V | |
| Primary voltage options | Manufacturer-specified 380 V and 420 V connections | |
| Primary adjustment tap | 20 V — confirm exact connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary output options | 55 V AC or 110 V AC | |
| Secondary winding arrangement | 110 V centre-tapped winding with a 55 V tap | |
| Calculated current at 110 V | Approximately 2.73 A, based on 300 VA | |
| 55 V tap current | Subject to ETE confirmation of permissible tap loading | |
| Operating frequency | 50/60 Hz | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding impregnation | Class H varnish | |
| Core earth connection | Provided | |
| Duty rating | Continuous | |
| Design standard | EN 61558-1 | |
| Ambient temperature range | −10 to +35 °C | |
| Length | 120 mm | |
| Width | 100 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 100 × 120 mm | |
| Weight | 4.7 kg | |
| Enclosure references | EPH 3 or EPN 2 | |
| Manufacturer catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV300P2S1 is a 300 VA single-phase multi-voltage control transformer used to supply compatible industrial control circuits requiring nominal 55 V AC or 110 V AC. Typical applications include electrical control panels, industrial machinery, contactors and relay circuits.
The transformer has 20/0/380/420 V primary terminals, including a 20 V adjustment tap. The exact terminal connections and adjustment method must be confirmed with ETE before installation.
Yes. The transformer has 0/55/110 V secondary terminals, providing nominal 55 V AC and 110 V AC connection options. The permissible loading of the 55 V tap should be confirmed with ETE.
At the full 300 VA rating, the calculated nominal output current is approximately 2.73 A at 110 V AC. Connected load and switching inrush requirements must also be considered.
Not without manufacturer confirmation. The 300 VA rating applies to the transformer, but it does not independently establish the permissible current or apparent power available from the individual 55 V winding section. Confirm the tap loading limits with ETE.
The 20 V adjustment tap forms part of the transformer's multi-voltage primary arrangement. Its exact function and terminal connections must be confirmed with ETE using the approved wiring diagram.
The transformer measures 120 × 100 × 120 mm, weighs 4.7 kg, has Class E insulation and 8% voltage regulation, and uses the specified enclosure references EPH 3 or EPN 2.
The ETE MV300P2S1 combines a 300 VA rating, 20/0/380/420 V primary terminals and selectable 55 V or 110 V secondary connections in a compact industrial control transformer. With Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure options, it is a practical choice for electrical panel builders, OEM machinery manufacturers and industrial maintenance engineers. Confirm the 20 V primary adjustment tap connections and permissible secondary tap loading with ETE before commissioning.