ETE MV3000P1S1 is a 3000 VA single-phase multi-voltage control transformer with 10/0/220/240 V primary terminals, selectable 55 V or 110 V AC secondary taps, Class E insulation, 3% voltage regulation and EPN 5 enclosure compatibility.
£262.28
The ETE MV3000P1S1 is a heavy-duty 3000 VA single-phase multi-voltage control transformer designed to provide dependable AC power for industrial machinery, electrical control panels and automation systems. Part of the ETE MV multi-voltage control transformer series, this transformer combines a flexible primary voltage arrangement with a tapped secondary winding, allowing the selection of nominal 55 V AC or 110 V AC outputs for compatible electrical equipment.
The MV3000P1S1 features 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. Its multi-voltage primary configuration supports the specified supply arrangements, while the secondary taps allow electrical engineers to select the appropriate control voltage. The transformer incorporates a 10 V primary adjustment tap, for which the correct connections must be confirmed with ETE before installation or energisation.
With a substantial rated capacity of 3000 VA (3 kVA), Class E insulation and a specified 3% voltage regulation, the ETE MV3000P1S1 is suitable for demanding industrial control power applications. Its robust construction, dimensions of 192 × 189 × 185 mm and weight of 28 kg make it appropriate for suitably supported industrial electrical installations. The specified EPN 5 enclosure reference supports selection of a compatible protective enclosure.
The ETE MV3000P1S1 multi-voltage transformer transfers electrical energy between its primary and secondary windings through electromagnetic induction. Its specified primary terminals provide multiple connection possibilities, while the secondary winding incorporates 55 V and 110 V taps for selecting the required nominal output voltage.
The transformer has a rated apparent power of 3000 VA, equivalent to 3 kVA. At a nominal 110 V AC secondary output, this corresponds to a calculated full-load current of approximately 27.27 A. The permissible loading of individual secondary taps must follow the manufacturer's winding ratings and connection instructions.
The specified 3% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. This characteristic is useful in industrial control systems where maintaining a reasonably consistent supply voltage under changing load conditions is important.
The 10 V primary adjustment tap forms part of the specified primary terminal arrangement. Because incorrect transformer connections can produce unsuitable voltages or damage electrical equipment, the correct primary tap connections must be confirmed with ETE before energising the MV3000P1S1.
Its Class E insulation, high apparent power rating and robust construction make this transformer suitable for appropriately designed industrial electrical systems. The specified EPN 5 enclosure reference provides an enclosure selection option, while the transformer's 28 kg weight must be considered when designing its mounting arrangement.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 3000 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | MV Multi-Voltage Control Transformers | |
| Model | MV3000P1S1 | |
| Product type | Multi-voltage control transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 3000 VA | |
| Rated apparent power (kVA) | 3 kVA | |
| Primary terminals | 10/0/220/240 V | |
| Primary adjustment tap | 10 V; confirm connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Output connection | 55 V or 110 V taps | |
| Nominal secondary output options | 55 V AC or 110 V AC | |
| Calculated full-load secondary current at 110 V | Approximately 27.27 A | |
| Insulation class | Class E | |
| Voltage regulation | 3% | |
| Enclosure reference | EPN 5 | |
| Length | 192 mm | |
| Width | 189 mm | |
| Height | 185 mm | |
| Dimensions (L × W × H) | 192 × 189 × 185 mm | |
| Weight | 28 kg | |
| Product range | ETE Stock Control Transformer Range | |
| Reference | ETE Price List March 2026 |
The ETE MV3000P1S1 is a 3000 VA single-phase multi-voltage control transformer designed to provide 55 V AC or 110 V AC control power for compatible industrial machinery and electrical equipment.
The transformer features 10/0/220/240 V primary terminals, including a 10 V adjustment tap. The correct primary connections must be confirmed with ETE.
The transformer has 0/55/110 V secondary terminals, providing nominal 55 V AC or 110 V AC output taps when connected correctly.
The transformer is rated at 3000 VA (3 kVA), making it suitable for substantial industrial control circuit loads within its specified ratings.
At the nominal 110 V AC secondary output, the 3000 VA rating corresponds to a calculated full-load current of approximately 27.27 A, subject to the manufacturer's winding and terminal ratings.
The 10 V primary adjustment tap is part of the transformer's specified multi-voltage primary arrangement. The correct use and connections of this tap must be confirmed with ETE before installation.
The ETE MV3000P1S1 incorporates Class E insulation and has a specified 3% voltage regulation.
The transformer measures 192 × 189 × 185 mm and weighs 28 kg.
The specified enclosure reference is EPN 5, which should be selected according to the requirements of the intended electrical installation.
ETE MV multi-voltage control transformers provide flexible power conversion for industrial electrical systems. The MV3000P1S1 combines a substantial 3 kVA rating, selectable 55 V or 110 V secondary taps, Class E insulation and 3% voltage regulation for demanding industrial control power applications.
The ETE SV250P5S4 is a dependable 250 VA single-phase control transformer designed to convert a nominal 415 V AC primary supply into a 110 V AC secondary output for industrial electrical control circuits, machinery and automation equipment. As part of the ETE SV single-voltage control transformer series, it provides a practical solution for electrical panel builders and industrial engineers requiring a dedicated 110 V AC control supply.
The transformer features 0/415 V primary terminals and 0/110 V secondary terminals, providing a straightforward single-voltage connection arrangement. Its Class E insulation system and specified 8% voltage regulation support reliable voltage conversion in appropriately designed industrial electrical installations.
With a rated apparent power of 250 VA, the ETE SV250P5S4 is suitable for supplying compatible 110 V AC contactors, relays, signalling devices and auxiliary electrical control equipment. Its dimensions of 120 × 88 × 120 mm, weight of 3.9 kg and specified EPH 3 or EPN 2 enclosure references make it a practical option for industrial machinery and control panel construction.
The ETE SV250P5S4 single-voltage transformer uses electromagnetic induction to convert a nominal 415 V AC primary input into a nominal 110 V AC secondary output. Its separate primary and secondary windings provide galvanic isolation between the supply and control circuits, making it suitable for appropriately designed industrial electrical systems.
The transformer's 250 VA rating corresponds to a calculated nominal full-load secondary current of approximately 2.27 A at 110 V AC. This makes it suitable for compatible control relays, contactor coils and auxiliary electrical equipment, provided the total connected load and starting demands remain within the transformer's capabilities.
The specified 8% voltage regulation describes the change in secondary voltage between no-load and rated-load operation. This should be considered when selecting electrical devices that require a particular operating voltage, particularly where control circuit loading changes during machine operation.
The Class E insulation system supports dependable transformer operation, while its compact industrial construction allows installation within suitable electrical cabinets. The specified EPH 3 or EPN 2 enclosure references provide options for applications requiring additional transformer protection.
The ETE SV250P5S4 is a 250 VA single-phase control transformer used to provide a nominal 110 V AC supply from a 415 V AC input for industrial control panels and compatible electrical equipment.
The transformer has 0/415 V primary terminals and is designed for a nominal 415 V AC primary supply.
The transformer features 0/110 V secondary terminals and provides a nominal 110 V AC output.
The transformer has a rated apparent power of 250 VA, corresponding to a calculated full-load secondary current of approximately 2.27 A at 110 V AC.
The transformer incorporates Class E insulation, a thermal insulation classification associated with a temperature limit of 120 °C.
The specified 8% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. Actual secondary voltage depends on the primary supply and connected load.
The transformer measures 120 × 88 × 120 mm and weighs 3.9 kg.
The specified enclosure references are EPH 3 or EPN 2, providing enclosure options for suitable industrial electrical installations.
ETE SV single-voltage control transformers provide dependable voltage conversion for industrial machinery and electrical automation systems. The SV250P5S4 combines a 250 VA rating, 415 V AC primary input, 110 V AC secondary output, Class E insulation and 8% voltage regulation for reliable industrial control power applications.
The ETE SV250P0S6 is a reliable 250 VA single-phase control transformer designed to provide a nominal 24 V AC output from a 110 V AC primary supply for industrial control circuits, machinery and automation equipment. Part of the ETE SV single-voltage control transformer series, it offers dependable low-voltage AC power conversion for electrical engineers, panel builders and industrial machinery manufacturers.
The transformer features 0/110 V primary terminals and 0/24 V secondary terminals, providing a straightforward connection arrangement for compatible electrical installations. Its Class E insulation system and specified 8% voltage regulation support reliable operation in industrial control power applications.
With a rated apparent power of 250 VA, the ETE SV250P0S6 is suitable for supplying compatible 24 V AC contactors, relays, control devices and auxiliary electrical equipment. Its dimensions of 120 × 88 × 120 mm, weight of 3.9 kg and specified EPH 3 or EPN 2 enclosure references make it a practical solution for industrial electrical control panel construction.
The ETE SV250P0S6 single-voltage transformer uses electromagnetic induction to convert a nominal 110 V AC primary supply into a nominal 24 V AC secondary supply. Its separate primary and secondary windings provide electrical isolation between the supply and control circuits, supporting integration into appropriately designed industrial automation systems.
The transformer has a rated apparent power of 250 VA, corresponding to a calculated nominal full-load secondary current of approximately 10.42 A at 24 V AC. This makes it suitable for compatible 24 V AC control relays, contactors, signalling equipment and auxiliary electrical loads. The total connected load must remain within the transformer's rated capacity, with appropriate consideration for equipment starting currents.
The specified 8% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. This characteristic should be considered when supplying electrical equipment that requires a closely controlled operating voltage.
The Class E insulation system supports reliable thermal insulation performance, while the transformer's compact industrial construction makes it suitable for electrical control cabinets and machinery assemblies. The specified EPH 3 or EPN 2 enclosure references provide compatible enclosure choices for installations requiring additional protection.
The ETE SV250P0S6 is a 250 VA single-phase control transformer used to provide a nominal 24 V AC supply from a 110 V AC input for industrial control panels and compatible automation equipment.
The transformer has 0/110 V primary terminals and is designed for a nominal 110 V AC primary supply.
The transformer has 0/24 V secondary terminals and provides a nominal 24 V AC output.
The transformer is rated at 250 VA, corresponding to a calculated nominal full-load secondary current of approximately 10.42 A at 24 V AC.
The transformer incorporates Class E insulation, a thermal insulation classification associated with a temperature limit of 120 °C.
The specified 8% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. Actual secondary voltage depends on the input supply and connected load.
The transformer measures 120 × 88 × 120 mm and weighs 3.9 kg.
The specified enclosure references are EPH 3 or EPN 2, providing enclosure options for suitable industrial electrical installations.
Yes. Its 250 VA rating, 110 V AC primary input, 24 V AC secondary output and Class E insulation make it suitable for appropriately designed industrial control panels and electrical automation systems.
ETE SV single-voltage control transformers provide dependable low-voltage AC power for industrial electrical systems. The SV250P0S6 combines a 250 VA rating, 110 V AC primary input, 24 V AC secondary output, Class E insulation and 8% voltage regulation for reliable industrial control and automation applications.
The ETE DV1000P6S4 is a robust 1000 VA single-phase dual-input-voltage control transformer designed to provide a dependable 110 V AC secondary supply for industrial electrical control circuits, machinery and automation systems. Part of the ETE DV dual-input-voltage transformer series, it offers flexible primary connections for industrial installations operating from nominal 240 V or 415 V AC supplies.
The transformer features 0/240/415 V primary terminals and 0/110 V secondary terminals, allowing the appropriate primary connection to be selected while providing a nominal 110 V AC secondary output. This makes the DV1000P6S4 suitable for industrial control panels, switchgear and machinery requiring a dedicated transformer-fed control supply.
With a rated capacity of 1000 VA (1 kVA), Class E insulation and a specified 4% voltage regulation, the ETE DV1000P6S4 is designed for substantial industrial control power requirements. Its dimensions of 150 × 125 × 145 mm, weight of 9.8 kg and specified EPN 3 enclosure reference support integration into suitably designed electrical installations.
The ETE DV1000P6S4 dual-input-voltage transformer uses electromagnetic induction to convert electrical energy from its primary winding into a nominal 110 V AC secondary supply. Its 0/240/415 V primary terminals allow connection to the appropriate 240 V or 415 V AC supply, providing flexibility for industrial electrical installations.
The transformer's 1000 VA (1 kVA) rating corresponds to a calculated nominal full-load secondary current of approximately 9.09 A at 110 V AC. This capacity makes it suitable for appropriately rated control relays, contactors, signalling equipment and auxiliary electrical systems. The total connected load and any significant inrush current requirements should be considered when selecting the transformer.
The specified 4% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. This characteristic supports predictable control circuit voltage performance where electrical loads change during machinery operation.
The Class E insulation system and robust industrial construction support integration into electrical control panels and machinery cabinets. The specified EPN 3 enclosure reference provides a suitable enclosure selection option, while the transformer's weight of 9.8 kg should be considered when designing the mounting arrangement.
The ETE DV1000P6S4 is a 1000 VA single-phase dual-input-voltage control transformer designed to provide nominal 110 V AC power for compatible industrial control circuits and electrical equipment.
The transformer has 0/240/415 V primary terminals, allowing connection to the appropriate nominal 240 V or 415 V AC supply.
The transformer has 0/110 V secondary terminals and provides a nominal 110 V AC output when correctly connected.
The transformer has a rated apparent power of 1000 VA (1 kVA), making it suitable for substantial industrial control power applications.
At its nominal 110 V AC secondary output, the 1000 VA rating corresponds to a calculated full-load secondary current of approximately 9.09 A.
The transformer incorporates Class E insulation, a thermal insulation classification associated with a temperature limit of 120 °C.
The specified 4% voltage regulation describes the change in secondary voltage between no-load and rated-load operation, helping engineers assess voltage stability under varying control circuit loads.
The transformer measures 150 × 125 × 145 mm and weighs 9.8 kg.
The specified enclosure reference is EPN 3, which should be selected according to the requirements of the intended electrical installation.
ETE DV dual-input-voltage control transformers provide dependable electrical power conversion for industrial machinery and automation systems. The DV1000P6S4 combines a 1 kVA rating, selectable 240 V or 415 V AC primary connections, a 110 V AC secondary output, Class E insulation and 4% voltage regulation for reliable industrial control power applications.