Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV250P1S3 is a 250 VA single-phase multi-voltage industrial control transformer with 10/0/220/240 V primary terminals and dual 0/12 V secondary windings. Its secondary output can be configured for 12 V AC in parallel or 24 V AC in series. The 10 V primary adjustment tap connections must be confirmed with ETE. Class E insulation, 8% voltage regulation, dimensions of 120 x 88 x 120 mm, weight of 3.9 kg and EPH 3 or EPN 2 enclosure references.
£47.40
The ETE MV250P1S3 is a 250 VA single-phase multi-voltage industrial control transformer featuring a tapped primary winding and two nominal 12 V AC secondary windings. Part of the ETE MV stock control transformer range, this model is designed for electrical panel builders, OEM machinery manufacturers and industrial automation applications requiring a configurable low-voltage AC control supply.
The transformer features 10/0/220/240 V primary terminals and 0/12 V + 0/12 V secondary terminals. Its secondary windings can be connected in parallel for a nominal 12 V AC output or in series for a nominal 24 V AC output. This allows the same transformer model to serve compatible control circuits with different AC voltage requirements.
The MV250P1S3 also incorporates a 10 V primary adjustment tap. The correct use of this tap, and the associated primary terminal connections, must be confirmed with ETE. The terminal markings should not be interpreted as a complete wiring diagram or used to infer unverified supply configurations.
With a 250 VA apparent power rating, Class E insulation and 8% voltage regulation, the MV250P1S3 offers a practical option for industrial control circuits requiring either 12 V AC or 24 V AC. Its overall dimensions are 120 × 88 × 120 mm, and its specified weight is 3.9 kg.
The transformer is listed in the ETE Stock Control Transformer Range, March 2026, with specified enclosure references of EPH 3 or EPN 2.
The ETE MV250P1S3 has a tapped primary winding identified by the terminals 10/0/220/240 V. This arrangement provides flexibility for compatible AC supply configurations, but the correct terminal selection must follow the manufacturer's wiring diagram.
The 10 V primary adjustment tap is a specific feature of this model. Its exact use and the approved terminal combinations must be confirmed with ETE before installation. The 10 V marking should not be interpreted as an independently rated 10 V primary input.
Electrical designers should verify the intended supply voltage, primary connection and expected secondary voltage before energising the transformer. Incorrect primary wiring may produce an unsuitable output voltage or damage the equipment.
The MV250P1S3 incorporates two separate 0/12 V secondary windings. These windings provide a choice of nominal secondary output voltage through the appropriate series or parallel connection.
For a nominal 12 V AC output, the two secondary windings are connected in parallel. When correctly connected with matching polarity, the output remains at 12 V AC and the winding current capabilities are combined within the transformer's overall rating.
Correct polarity is essential when connecting transformer windings in parallel. An incorrect connection can create excessive circulating current, overheating or transformer damage. The manufacturer's connection diagram should always be followed.
For a nominal 24 V AC output, the two secondary windings are connected in series. When connected with the correct polarity, the nominal voltages of the two 12 V windings add together.
The secondary winding configuration should be selected according to the voltage requirements of the connected equipment. The 12 V and 24 V options are alternative output configurations, not two independent 250 VA supplies.
The MV250P1S3 has a total rated apparent power of 250 VA. The current corresponding to each nominal secondary configuration can be calculated using:
Current (A) = Apparent power (VA) ÷ Secondary voltage (V)
For a correctly connected 12 V AC parallel output:
250 VA ÷ 12 V = approximately 20.83 A
This represents the calculated total nominal full-load secondary current at 12 V AC, based on the complete transformer rating. It is not a separately confirmed manufacturer terminal rating.
For a correctly connected 24 V AC series output:
250 VA ÷ 24 V = approximately 10.42 A
This represents the calculated nominal full-load secondary current at 24 V AC, based on the complete transformer rating.
The connected load must remain within the applicable transformer rating and any manufacturer-specified winding or terminal limits. Inrush current, load characteristics and protective device selection should also be considered during electrical design.
The ETE MV250P1S3 has a specified 8% voltage regulation. Voltage regulation describes the change in transformer secondary voltage between no-load and rated-load conditions under defined test conditions.
The actual secondary voltage may vary with primary supply conditions and connected load. Consequently, the nominal 12 V AC and 24 V AC outputs should not be interpreted as electronically stabilised voltages.
For control equipment with narrow operating voltage tolerances, engineers should consider the regulation characteristic and expected supply variation before selecting the transformer.
Before installing the ETE MV250P1S3, confirm the available primary supply, required secondary voltage, total connected apparent power and correct winding connections.
Primary wiring: The 10/0/220/240 V terminal arrangement includes a 10 V adjustment tap. The correct primary terminal connections must be confirmed with ETE before energising the transformer.
Secondary wiring: The two 0/12 V secondary windings must be connected in parallel for a nominal 12 V AC output or in series for a nominal 24 V AC output. Correct winding polarity is essential in both configurations.
The installation should incorporate suitable primary and secondary circuit protection, appropriate conductor sizing, protective earthing where applicable, ventilation and secure mechanical mounting.
The specified EPH 3 or EPN 2 enclosure references should be checked against the intended installation requirements. An enclosure reference does not necessarily mean an enclosure is included with the transformer.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 250 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model / SKU | MV250P1S3 | |
| Product type | Industrial multi-voltage control transformer | |
| Transformer configuration | Tapped primary and dual secondary windings | |
| Number of phases | Single-phase | |
| Rated apparent power | 250 VA | |
| Primary terminals | 10/0/220/240 V | |
| Primary adjustment tap | 10 V | |
| Primary connection note | Confirm connections with ETE | |
| Secondary terminals | 0/12 V + 0/12 V | |
| Secondary winding arrangement | Two nominal 12 V AC windings | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Output connection | 12 V parallel or 24 V series | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Calculated nominal full-load secondary current at 12 V AC | Approximately 20.83 A total, based on 250 VA | |
| Calculated nominal full-load secondary current at 24 V AC | Approximately 10.42 A, based on 250 VA | |
| Length | 120 mm | |
| Width | 88 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 88 × 120 mm | |
| Weight | 3.9 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV250P1S3 is a 250 VA single-phase multi-voltage control transformer designed for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. Its dual secondary windings provide selectable 12 V AC or 24 V AC output configurations.
The primary terminals are specified as 10/0/220/240 V. The correct terminal connections, including the 10 V adjustment tap, must be confirmed with ETE.
The MV250P1S3 includes a 10 V primary adjustment tap as part of its tapped primary winding. Its exact function and approved terminal connections must be confirmed with ETE before installation.
The secondary terminals are specified as 0/12 V + 0/12 V, representing two separate nominal 12 V AC secondary windings.
Yes. The two secondary windings can be connected in parallel to provide a nominal 12 V AC output, provided the correct winding polarity and manufacturer's wiring instructions are followed.
Yes. The two secondary windings can be connected in series to provide a nominal 24 V AC output, with the correct winding polarity so their voltages add together.
The ETE MV250P1S3 has a rated apparent power of 250 VA. This rating applies to the complete transformer rather than separately to each secondary winding.
At a nominal 12 V AC output, the 250 VA rating corresponds to approximately 20.83 A total when the secondary windings are correctly connected in parallel. This is a calculated value for load assessment.
At a nominal 24 V AC output, the 250 VA rating corresponds to approximately 10.42 A when the secondary windings are correctly connected in series. This is a calculated value for load assessment.
The MV250P1S3 has a specified Class E insulation system.
The ETE MV250P1S3 has a specified 8% voltage regulation. This should be considered when assessing the operating voltage requirements of connected equipment.
The transformer measures 120 mm long, 88 mm wide and 120 mm high, with a specified weight of 3.9 kg.
The specified enclosure references are EPH 3 or EPN 2. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
Correct winding polarity is essential when connecting the two 12 V secondary windings in series or parallel. Incorrect connections can cause opposing voltages, excessive circulating current or transformer damage. Always follow the ETE connection diagram.
No. The ETE MV250P1S3 provides a nominal 12 V AC or 24 V AC output, depending on the secondary winding configuration. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
The MV250P1S3 has a 10/0/220/240 V primary terminal arrangement incorporating a 10 V adjustment tap. Confirming the ETE connection diagram helps prevent incorrect wiring and ensures the intended primary configuration is selected.
When selecting the ETE MV250P1S3, verify that the intended primary supply can be accommodated using the manufacturer's approved terminal arrangement. The 10 V primary adjustment tap must be connected only in accordance with ETE's instructions.
Next, determine whether the connected equipment requires a nominal 12 V AC or 24 V AC supply. The two secondary windings must be configured correctly in parallel or series, with the appropriate polarity.
The transformer's 250 VA rating, 8% voltage regulation, Class E insulation, 120 × 88 × 120 mm dimensions and 3.9 kg weight should all be considered during electrical and mechanical design.
The ETE MV250P1S3 combines a 250 VA rating with a tapped 10/0/220/240 V primary and dual 12 V secondary windings. Its selectable 12 V AC parallel or 24 V AC series output, Class E insulation and 8% voltage regulation make it a practical option for compatible industrial control panels and OEM machinery. Always confirm the 10 V primary adjustment tap connections with ETE.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.