ETE MV250P1S1 is a 250 VA single-phase multi-voltage industrial control transformer with 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. It provides selectable nominal 55 V AC or 110 V AC output connections. The 10 V primary adjustment tap connections must be confirmed with ETE. The transformer features Class E insulation, 8% voltage regulation, dimensions of 120 x 88 x 120 mm, weight of 3.9 kg and EPH 3 or EPN 2 enclosure references.
£47.40
The ETE MV250P1S1 is a 250 VA single-phase multi-voltage industrial control transformer featuring a tapped primary winding and a selectable 55 V AC or 110 V AC secondary output. Part of the ETE MV multi-voltage stock control transformer range, this model is designed for industrial electrical control panels, OEM machinery and automation systems requiring a compatible AC control supply.
The transformer features 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. The secondary taps allow the appropriate nominal output voltage to be selected for equipment requiring either 55 V AC or 110 V AC, subject to the manufacturer's approved wiring arrangement.
An important feature of the MV250P1S1 is its 10 V primary adjustment tap. This provides additional flexibility in primary voltage selection, but the precise terminal arrangement must be confirmed with ETE. Do not assume the correct adjustment tap connections from the terminal markings alone.
With a 250 VA apparent power rating, Class E insulation and 8% voltage regulation, the MV250P1S1 offers a practical solution for compatible industrial control loads. Its dimensions are 120 × 88 × 120 mm, with a specified weight of 3.9 kg.
The transformer is listed in the ETE Stock Control Transformer Range, March 2026, with specified enclosure references of EPH 3 or EPN 2.
The ETE MV250P1S1 incorporates a tapped primary winding identified by the terminals 10/0/220/240 V. This arrangement provides flexibility for compatible AC supply configurations, with the correct connection determined by the manufacturer's wiring diagram.
The 10 V primary adjustment tap requires particular attention. Although the terminal markings identify the available winding taps, they do not independently establish every permissible supply connection. The adjustment tap should not be treated as a standalone 10 V input.
Confirm the intended primary supply connection with ETE before energising the transformer. This is especially important when using the adjustment tap or replacing an existing transformer with a different terminal arrangement.
On the secondary side, the 0/55/110 V terminal arrangement provides selectable nominal AC output voltages. The appropriate secondary connection can be selected for compatible equipment requiring either 55 V AC or 110 V AC.
The two secondary voltage options are taps on the specified secondary arrangement. They should not be interpreted as two independent 250 VA outputs. Any simultaneous use of multiple taps, including permissible combined loading, must be confirmed against the manufacturer's technical documentation.
The 55 V AC tap allows the MV250P1S1 to supply compatible equipment requiring a nominal 55 V AC control voltage. The actual terminal connection must follow the ETE wiring diagram.
This option may be useful for specialist industrial control circuits, replacement equipment and machinery designed around a 55 V AC supply.
The 110 V AC tap provides a nominal 110 V AC secondary output for compatible control equipment. This voltage is commonly encountered in industrial control applications, including suitable AC relay and contactor circuits.
Before connecting a load, verify its nominal voltage, apparent power requirements and acceptable operating voltage range.
The MV250P1S1 has a rated apparent power of 250 VA. The current corresponding to a particular nominal secondary voltage can be calculated using:
Current (A) = Apparent power (VA) ÷ Secondary voltage (V)
For a nominal 55 V AC output:
250 VA ÷ 55 V = approximately 4.55 A
This is the mathematical current corresponding to the full 250 VA rating at 55 V AC. It is not independent confirmation of the manufacturer's permissible loading for the 55 V tap.
For a nominal 110 V AC output:
250 VA ÷ 110 V = approximately 2.27 A
This is the mathematical current corresponding to the full 250 VA rating at 110 V AC.
The transformer's overall 250 VA rating must not be counted separately for each secondary tap. The connected load, permissible tap loading and any simultaneous use of output connections should be assessed using ETE's technical documentation.
Where electromagnetic contactors, relays or other inductive loads are connected, starting and inrush requirements should also be considered.
The ETE MV250P1S1 has a specified 8% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under defined conditions.
The actual secondary voltage may therefore vary with the applied primary voltage and the connected load. The nominal 55 V AC and 110 V AC output values should not be interpreted as guaranteed constant voltages under all operating conditions.
Electrical designers should consider the 8% regulation characteristic when selecting connected equipment with defined voltage tolerances.
Before installing the ETE MV250P1S1, verify the available primary supply, intended secondary output, connected load and correct winding connections.
Primary connection: The 10/0/220/240 V terminals include a 10 V adjustment tap. Confirm the correct connection arrangement with ETE rather than relying on assumptions about the terminal markings.
Secondary connection: The 0/55/110 V terminals provide nominal 55 V AC and 110 V AC output options. Use the approved terminal combination for the required voltage.
Suitable primary and secondary circuit protection, conductor sizing, protective earthing where applicable, ventilation and secure mechanical mounting should be incorporated into the installation design.
The specified EPH 3 or EPN 2 enclosure references should be checked against the intended installation requirements. An enclosure reference alone does not establish the environmental protection rating of the complete assembly.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 250 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Control Transformer Range | |
| Model / SKU | MV250P1S1 | |
| Product type | Industrial multi-voltage control transformer | |
| Transformer configuration | Tapped primary and tapped secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 250 VA | |
| Primary terminals | 10/0/220/240 V | |
| Primary adjustment tap | 10 V | |
| Primary connection note | Confirm terminal connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary output options | 55 V AC or 110 V AC | |
| Output connection | 55 V or 110 V taps | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Calculated current at nominal 55 V AC | Approximately 4.55 A, based on 250 VA | |
| Calculated current at nominal 110 V AC | Approximately 2.27 A, based on 250 VA | |
| Length | 120 mm | |
| Width | 88 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 88 × 120 mm | |
| Weight | 3.9 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV250P1S1 is a 250 VA single-phase multi-voltage control transformer intended for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. It features a tapped primary and selectable 55 V AC or 110 V AC secondary output.
The primary terminals are specified as 10/0/220/240 V. The correct connections, including the 10 V adjustment tap, must be confirmed with ETE.
The MV250P1S1 includes a 10 V primary adjustment tap as part of its tapped primary winding. Its exact use and correct terminal connections must be confirmed with ETE before installation.
The secondary terminals are specified as 0/55/110 V, providing nominal 55 V AC and 110 V AC output options using the appropriate connections.
Yes. The MV250P1S1 has a 55 V AC secondary tap. The correct terminal connection and permissible loading should be checked against the ETE datasheet.
Yes. The MV250P1S1 has a 110 V AC secondary tap for compatible industrial control equipment. The correct terminal connection must follow the manufacturer's instructions.
The ETE MV250P1S1 has a rated apparent power of 250 VA. This is the overall transformer rating and must not be counted separately for each secondary tap.
At a nominal 55 V AC output, 250 VA corresponds mathematically to approximately 4.55 A. The permissible loading of the 55 V tap must still be verified against the manufacturer's documentation.
At a nominal 110 V AC output, 250 VA corresponds mathematically to approximately 2.27 A. This calculated value is for load assessment and does not replace the manufacturer's terminal ratings.
Do not assume that both secondary taps can supply independent loads simultaneously. Any permitted simultaneous loading and the combined current limits must be confirmed with ETE.
The MV250P1S1 has a specified Class E insulation system.
The ETE MV250P1S1 has a specified 8% voltage regulation. This should be considered when assessing the operating voltage requirements of connected equipment.
The transformer measures 120 mm long, 88 mm wide and 120 mm high, with a specified weight of 3.9 kg.
The specified enclosure references are EPH 3 or EPN 2. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
No. The ETE MV250P1S1 is an AC control transformer providing nominal 55 V AC or 110 V AC output connections. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
The MV250P1S1 has a 10/0/220/240 V primary terminal arrangement incorporating a 10 V adjustment tap. Confirming the ETE connection diagram helps prevent incorrect wiring and ensures the intended supply configuration is selected.
When specifying the ETE MV250P1S1, first confirm that the primary supply can be accommodated using the manufacturer's approved terminal arrangement. The 10 V adjustment tap must be connected only in accordance with ETE's instructions.
Next, confirm whether the connected equipment requires a nominal 55 V AC or 110 V AC output. Assess the total connected apparent power, any inrush requirements and the permissible loading of the selected secondary tap.
The transformer's 250 VA rating, 8% voltage regulation, Class E insulation, 120 × 88 × 120 mm dimensions and 3.9 kg weight should be considered during electrical and mechanical design.
The ETE MV250P1S1 combines a 250 VA rating with a tapped 10/0/220/240 V primary and selectable 55 V AC or 110 V AC secondary connections. Its Class E insulation, 8% voltage regulation and specified EPH 3 or EPN 2 enclosure references make it a practical option for compatible industrial control applications. Always confirm the 10 V primary adjustment tap connections with ETE.