ETE MV2500P2S1 is a 2500 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary connections, Class E insulation, 3% voltage regulation and EPN 5 enclosure compatibility.
£231.30
The ETE MV2500P2S1 is a high-capacity 2500 VA (2.5 kVA) single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring dependable AC voltage transformation. Part of the ETE MV multi-voltage control transformer range, this model features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, providing nominal 55 V AC or 110 V AC output connections for compatible industrial control equipment.
With a substantial 2500 VA apparent power rating, the MV2500P2S1 is particularly suitable for larger industrial control circuits containing multiple contactors, electromagnetic relays, signalling devices, solenoids and other AC-operated components. Its higher capacity makes it a practical choice for installations where smaller control transformers cannot accommodate the total connected apparent power or anticipated operating demands.
The primary winding incorporates terminals marked 380 V and 420 V, together with a 20 V primary adjustment tap. This multi-terminal arrangement provides connection flexibility for compatible industrial AC supplies. However, the precise purpose of the adjustment terminal and the permitted primary connection combinations must be confirmed with ETE before installation.
On the secondary side, the 0/55/110 V tapped winding provides nominal 55 V AC or 110 V AC output connections. This arrangement allows the transformer to serve different control voltage requirements, subject to the manufacturer's approved connection instructions and applicable winding and tap loading limits.
Featuring Class E insulation and 3% voltage regulation, the MV2500P2S1 provides defined electrical characteristics for industrial transformer selection. Its dimensions of 192 × 161 × 185 mm and weight of 24 kg should be considered when designing mounting arrangements and electrical cabinet layouts. The specified compatible enclosure reference is ETE EPN 5.
Listed in the ETE Stock Control Transformer Range, March 2026, the MV2500P2S1 is a practical solution for electrical panel builders, machinery manufacturers and maintenance engineers requiring a higher-capacity single-phase transformer with selectable AC control voltage connections.
The ETE MV2500P2S1 provides a high-capacity solution for industrial electrical installations requiring selectable 55 V AC or 110 V AC control voltage. Its 20/0/380/420 V primary arrangement and 0/55/110 V secondary winding make it suitable for control panel designs where a compatible industrial AC supply must be transformed to a lower-voltage control circuit.
The primary winding includes terminals marked 380 V and 420 V, together with a 20 V adjustment tap. These markings identify the available winding connections but do not independently establish every permissible supply voltage arrangement. The 20 V adjustment terminal should not be treated as an independent low-voltage supply input. The correct primary terminal combinations must be verified using ETE's approved connection information before the transformer is energised.
The secondary winding incorporates an intermediate 55 V tap and a full 110 V connection. This provides nominal secondary voltage options for compatible industrial control equipment. Where the transformer is being considered for a centre-tapped 110 V control circuit, the intended connection arrangement and any centre-point earthing requirements should be verified against the manufacturer's documentation.
At the total rated apparent power of 2500 VA, the calculated nominal full-load current at 110 V AC is approximately 22.73 A. This value is obtained by dividing the transformer rating by the nominal full secondary voltage. The permissible current through the intermediate 55 V winding section has not been specified separately and must be confirmed with ETE before applying a substantial load to that tap.
The specified 3% voltage regulation is an important characteristic for industrial control circuits containing electromagnetic devices. Contactors, relays and solenoids can draw greater apparent power during energisation than during normal operation, potentially causing temporary changes in secondary voltage. Electrical designers should therefore consider the total steady-state load, simultaneous switching demands and acceptable operating voltage range of connected equipment.
With a rated capacity of 2.5 kVA, the MV2500P2S1 is particularly relevant to larger control systems containing multiple compatible AC devices. Transformer selection should consider the aggregate apparent power requirement, permissible winding and tap loading, and any additional capacity needed for equipment energisation.
The MV2500P2S1 features Class E insulation, dimensions of 192 × 161 × 185 mm and a weight of 24 kg. These characteristics should be considered when selecting mounting arrangements, mechanical supports and enclosure space. The specified compatible enclosure reference is ETE EPN 5.
The transformer provides AC voltage transformation rather than regulated DC output. Equipment requiring DC control voltage will need appropriate additional conversion components. Installation should account for correct primary tap selection, suitable primary and secondary circuit protection, conductor sizing, secure mounting, ventilation and protective earthing where applicable.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 2500 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Manufacturer part number | MV2500P2S1 | |
| Product family | MV Multi-Voltage Control Transformers | |
| Product category | Industrial Control Transformers | |
| Transformer configuration | Tapped primary and secondary windings | |
| Number of phases | Single-phase | |
| Rated apparent power | 2500 VA | |
| Rated apparent power in kVA | 2.5 kVA | |
| Primary terminal arrangement | 20/0/380/420 V | |
| Primary voltage terminal markings | 380 V and 420 V | |
| Primary adjustment tap | 20 V | |
| Primary connection note | Confirm the correct 20 V adjustment tap connections with ETE before energising. | |
| Secondary terminal arrangement | 0/55/110 V | |
| Nominal secondary output options | 55 V AC or 110 V AC | |
| Calculated nominal full-load secondary current at 110 V | Approximately 22.73 A | |
| 55 V secondary tap current rating | Confirm with ETE before applying the full transformer apparent power to the intermediate tap. | |
| Calculated apparent-power current equivalent at 380 V primary | Approximately 6.58 A | |
| Calculated apparent-power current equivalent at 420 V primary | Approximately 5.95 A | |
| Insulation class | E | |
| Voltage regulation | 3% | |
| Length | 192 mm | |
| Width | 161 mm | |
| Height | 185 mm | |
| Overall dimensions (L × W × H) | 192 × 161 × 185 mm | |
| Weight | 24 kg | |
| Compatible enclosure reference | EPN 5 | |
| Typical installation | Industrial electrical control panels and machinery cabinets | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV2500P2S1 is a 2500 VA single-phase multi-voltage control transformer designed to provide nominal 55 V AC or 110 V AC secondary connections for compatible industrial control equipment.
The transformer has a rated apparent power of 2500 VA, equivalent to 2.5 kVA. Connected equipment must remain within the applicable transformer and winding ratings.
The primary terminal markings are 20/0/380/420 V. The correct connection arrangement, particularly the function of the 20 V adjustment tap, must be confirmed with ETE.
The 20 V primary adjustment tap provides an additional winding connection. Its precise relationship to the 0, 380 V and 420 V terminals must be verified using ETE's approved connection information before installation.
The transformer has primary terminals marked 380 V and 420 V, together with a 20 V adjustment tap. The correct connection arrangement for a nominal 400 V AC supply must be confirmed with ETE rather than inferred from terminal markings alone.
The secondary terminals are marked 0/55/110 V, providing nominal 55 V AC or 110 V AC output connections when wired correctly.
The 0/55/110 V secondary arrangement includes an intermediate 55 V tap on the 110 V winding. The suitability of this arrangement for a particular centre-tapped application, including any centre-point earthing requirements, must be confirmed from ETE's connection information.
At 2500 VA and 110 V AC, the calculated nominal full-load secondary current is approximately 22.73 A.
Not without confirmation. The transformer has a total rated apparent power of 2500 VA, but the allowable current through the individual 55 V winding section has not been specified separately. The applicable tap loading limit should be confirmed with ETE.
Dividing the rated apparent power by the marked primary voltages gives approximately 6.58 A at 380 V and 5.95 A at 420 V. These are mathematical apparent-power equivalents rather than independently verified operating input currents.
The transformer provides AC output. It does not incorporate a rectifier or regulated DC power supply.
The transformer has Class E insulation and a specified 3% voltage regulation.
The transformer measures 192 mm long × 161 mm wide × 185 mm high and weighs 24 kg.
The specified compatible enclosure reference is ETE EPN 5. Final enclosure selection should account for the installation environment, mounting requirements, ventilation and the transformer's 24 kg weight.
Yes. Its 2500 VA rating, selectable secondary voltage connections and industrial transformer configuration make it suitable for appropriately designed control panels using compatible AC equipment.
The specified 3% voltage regulation describes secondary voltage variation under changing load conditions. Connected control equipment should have suitable operating voltage tolerances, particularly where electromagnetic devices produce high energisation demands.
The correct wiring information should be obtained from ETE or its approved technical documentation. This is especially important when using the 20 V primary adjustment tap or configuring the secondary winding for a particular control circuit.
The ETE MV2500P2S1 combines a substantial 2500 VA rating with flexible primary connections and selectable 55 V or 110 V AC secondary outputs. Its Class E insulation, 3% voltage regulation and EPN 5 enclosure compatibility make it a practical component for electrical panel builders, machinery manufacturers and maintenance engineers requiring higher-capacity industrial AC control power.