Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV200P1S3 is a 200 VA single-phase multi-voltage control transformer with 10/0/220/240 V primary terminals, two 12 V secondary windings configurable for 12 V AC parallel or 24 V AC series output, Class E insulation, 10% voltage regulation and EPH 2 or EPN 1 enclosure compatibility.
£36.15
The ETE MV200P1S3 is a versatile 200 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring flexible AC control voltage arrangements. Part of the ETE MV multi-voltage control transformer range, this model features 10/0/220/240 V primary terminals and two separate 0/12 V secondary windings, allowing the secondary outputs to be configured for 12 V AC parallel operation or 24 V AC series operation.
The MV200P1S3 is particularly useful for industrial installations where different low-voltage AC control requirements must be accommodated without changing the transformer model. Its dual secondary windings provide flexibility for supplying compatible relays, contactors, signalling devices, solenoid valves and other industrial control components. When correctly connected in parallel, the two secondary windings provide a nominal 12 V AC output; when connected in series with the correct winding polarity, they provide a nominal 24 V AC output.
The primary winding incorporates terminals marked 10/0/220/240 V, including a 10 V primary adjustment tap. The precise connection arrangement for this adjustment tap must be confirmed with ETE before installation. Correct terminal selection is essential to ensure the intended secondary voltage and safe transformer operation.
With a rated apparent power of 200 VA, Class E insulation and 10% voltage regulation, the MV200P1S3 provides practical voltage transformation for industrial control applications. Measuring 96 × 87 × 103 mm and weighing 2.8 kg, it is suitable for integration into electrical control cabinets. The specified compatible enclosure references are ETE EPH 2 or EPN 1.
The ETE MV200P1S3 is designed for industrial electrical control systems requiring a choice between 12 V AC and 24 V AC without changing the transformer itself. Its two separate 0/12 V secondary windings can be configured in parallel or series, providing useful flexibility for control panel manufacturers, machinery builders and maintenance engineers.
In the parallel configuration, the two 12 V secondary windings are connected with matching polarity to provide a nominal 12 V AC output. This arrangement is intended to combine the available current capacity of the two windings. Parallel connection must follow ETE's approved wiring diagram because incorrect polarity can create a damaging circulating current or an effective short circuit.
In the series configuration, the two 12 V windings are connected in the correct additive polarity to provide a nominal 24 V AC output. Incorrect series polarity can result in the winding voltages opposing each other rather than adding together. The correct terminal connections must therefore be verified before the transformer is energised.
The 200 VA apparent power rating gives a theoretical nominal output current of approximately 8.33 A at 24 V AC or 16.67 A at 12 V AC, assuming the full transformer rating is available in the relevant manufacturer-approved configuration. These figures are calculated from apparent power divided by output voltage and should not be treated as independently verified winding current ratings. The permissible current of each individual 12 V winding and the total allowable load must be confirmed from ETE's technical documentation.
The primary winding is marked 10/0/220/240 V and includes a 10 V adjustment tap. The terminal arrangement provides flexibility for compatible industrial AC supplies, but the adjustment tap must not be wired by assumption. Its exact purpose and permitted connection combinations should be confirmed directly with ETE or through the manufacturer's approved connection diagram.
The specified 10% voltage regulation is relevant when selecting equipment that must operate reliably across varying control circuit loads. Electromagnetic devices such as contactors, relays and solenoids may draw higher apparent power during initial energisation than during normal operation. The total connected load, simultaneous switching requirements and operating voltage tolerances should be assessed before selecting the transformer for a particular application.
With Class E insulation, a compact 96 × 87 × 103 mm construction and a weight of 2.8 kg, the MV200P1S3 is suitable for integration into appropriately designed industrial control cabinets. The specified EPH 2 or EPN 1 enclosure references offer compatible housing options where additional physical protection is required.
The MV200P1S3 supplies AC output and does not incorporate a rectifier or regulated DC power supply. Where connected equipment requires 12 V DC or 24 V DC, appropriate additional conversion equipment must be provided. Installation should include suitable primary and secondary circuit protection, protective earthing where required, conductor sizing, mounting and ventilation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 200 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Manufacturer part number | MV200P1S3 | |
| Product family | MV Multi-Voltage Control Transformers | |
| Product category | Industrial Control Transformers | |
| Transformer configuration | Multi-tapped primary with dual secondary windings | |
| Number of phases | Single-phase | |
| Rated apparent power | 200 VA | |
| Primary terminal arrangement | 10/0/220/240 V | |
| Primary voltage terminal markings | 220 V and 240 V | |
| Primary adjustment tap | 10 V | |
| Primary connection note | Confirm the correct 10 V adjustment tap connections with ETE before energising. | |
| Number of secondary windings | 2 | |
| Secondary winding 1 | 0/12 V | |
| Secondary winding 2 | 0/12 V | |
| Secondary terminal arrangement | 0/12 V + 0/12 V | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Calculated total output current at 12 V | Approximately 16.67 A, assuming the full 200 VA rating is available through the approved parallel connection. | |
| Calculated total output current at 24 V | Approximately 8.33 A, assuming the full 200 VA rating is available through the approved series connection. | |
| Calculated apparent-power current equivalent at 220 V | Approximately 0.91 A | |
| Calculated apparent-power current equivalent at 240 V | Approximately 0.83 A | |
| Insulation class | E | |
| Voltage regulation | 10% | |
| Length | 96 mm | |
| Width | 87 mm | |
| Height | 103 mm | |
| Overall dimensions (L × W × H) | 96 × 87 × 103 mm | |
| Weight | 2.8 kg | |
| Compatible enclosure references | EPH 2 or EPN 1 | |
| Typical installation | Industrial electrical control panels and machinery cabinets | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV200P1S3 is a 200 VA single-phase multi-voltage control transformer designed to provide nominal 12 V AC or 24 V AC output using two secondary windings connected in parallel or series.
The primary terminals are marked 10/0/220/240 V. The correct use of the 10 V primary adjustment tap must be confirmed with ETE before installation.
The 10 V primary adjustment tap provides an additional winding connection. Its precise function and relationship to the 0, 220 V and 240 V terminals must be verified using ETE's approved wiring information.
The transformer has two separate 0/12 V secondary windings, identified by the terminal arrangement 0/12 V + 0/12 V.
The two 12 V secondary windings can be connected in parallel with matching polarity to provide a nominal 12 V AC output. The connections must follow ETE's approved wiring diagram.
The two 12 V secondary windings can be connected in series with additive polarity to provide a nominal 24 V AC output.
No. Correct winding polarity is essential when connecting transformer secondaries in parallel. Incorrect connections can cause excessive circulating current, overheating or transformer damage. Follow the manufacturer's approved connection diagram.
If the windings are connected with opposing polarity, their voltages subtract rather than add. The correct additive series arrangement must be confirmed before using the transformer for a 24 V AC output.
The transformer has a rated apparent power of 200 VA. The total connected load must remain within the applicable transformer and winding ratings.
At 200 VA and 24 V AC, the theoretical nominal output current is approximately 8.33 A, assuming the full rated apparent power is available in the approved series configuration.
At 200 VA and 12 V AC, the theoretical nominal output current is approximately 16.67 A, assuming the full rated apparent power is available in the approved parallel configuration. Individual winding current limits must be verified.
The total transformer rating is 200 VA, but the individual secondary winding ratings have not been specified separately. The full 200 VA rating must not be assumed to apply independently to each winding.
The transformer provides 12 V AC or 24 V AC, depending on the secondary connection. It does not include a rectifier or regulated DC power supply.
The MV200P1S3 has Class E insulation and a specified 10% voltage regulation.
The transformer measures 96 mm long × 87 mm wide × 103 mm high and weighs 2.8 kg.
The specified compatible enclosure references are ETE EPH 2 or EPN 1. Final enclosure selection should account for the installation environment, mounting requirements and ventilation.
Yes. The transformer is intended for industrial control applications requiring compatible 12 V AC or 24 V AC circuits, provided the connected load, wiring arrangement and installation requirements are suitable.
The correct wiring information should be obtained from ETE or its approved technical documentation, particularly when using the 10 V primary adjustment tap or connecting the two 12 V secondary windings in series or parallel.
The ETE MV200P1S3 combines a 200 VA rating with flexible primary connections and two 12 V secondary windings that can be configured for 12 V or 24 V AC output. Its Class E insulation, 10% voltage regulation and compact construction make it a practical choice for electrical panel builders, machinery manufacturers and maintenance engineers requiring adaptable low-voltage AC control power.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.