ETE MV200P1S1 is a 200 VA single-phase multi-voltage control transformer with 10/0/220/240 V primary terminals, selectable 55 V or 110 V AC secondary connections, Class E insulation and 10% voltage regulation for industrial control applications.
£36.15
The ETE MV200P1S1 is a 200 VA single-phase multi-voltage control transformer designed to provide reliable AC control power for industrial machinery, electrical control panels and automation equipment. Part of the ETE MV Multi-Voltage Series, it features 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals, providing selectable nominal 55 V AC or 110 V AC output connections.
Manufactured by Eastern Transformers & Equipment (ETE), the MV200P1S1 is intended for industrial applications requiring flexible transformer voltage connections. Its secondary winding is also identified as 55/0/55 V, providing a 110 V AC winding with a 55 V centre tap. This arrangement is particularly useful in appropriately designed industrial control systems requiring 110 V AC or centre-tapped 55-0-55 V supplies.
With a 200 VA rated capacity, Class E insulation and 10% voltage regulation, the transformer provides a practical solution for industrial control circuit power distribution. Its dimensions are 96 × 87 × 103 mm, with a weight of 2.8 kg. The specified enclosure references are EPH 2 or EPN 1.
Important installation note: The primary winding includes a 10 V adjustment tap. The exact terminal connections and intended adjustment arrangement must be confirmed with ETE before installation or energisation.
The ETE MV200P1S1 multi-voltage transformer incorporates a 10/0/220/240 V primary terminal arrangement, providing connection options for industrial installations with nominal 220 V AC or 240 V AC supplies. This flexibility makes the transformer useful for electrical panel builders, OEM machinery manufacturers and maintenance engineers working with different control supply requirements.
The primary winding includes a 10 V adjustment tap. This terminal arrangement must be interpreted using the manufacturer's wiring instructions, as the adjustment connection cannot be determined safely from the terminal markings alone.
Connection requirement: Confirm the correct primary terminal arrangement and the intended use of the 10 V adjustment tap with ETE before energising the transformer. The selected connections must match the available supply voltage and the manufacturer's approved configuration.
The MV200P1S1 features a 0/55/110 V secondary terminal arrangement, corresponding to the manufacturer's 55/0/55 V centre-tapped winding. This allows the transformer to provide a nominal 110 V AC output across the complete secondary winding or a nominal 55 V AC output between the appropriate centre-tap and outer terminal.
For applications using the complete 110 V secondary winding, the 200 VA rating corresponds to a calculated nominal current of approximately 1.82 A. This is useful when selecting appropriately rated industrial control equipment, including contactors, relays and switching circuits.
For a 55 V output connection, dividing the total transformer rating by 55 V gives a theoretical current of approximately 3.64 A. However, this calculation does not establish the permissible current of an individual half-winding. The allowable 55 V tap loading must be confirmed with ETE before designing a circuit around that current.
The centre-tapped winding arrangement may also be useful in control systems requiring a 55-0-55 V supply. Any centre-tap earthing, secondary circuit protection or simultaneous loading arrangement should follow the manufacturer's guidance and the requirements of the complete electrical installation.
The ETE MV200P1S1 measures 96 mm in length, 87 mm in width and 103 mm in height, with a weight of 2.8 kg. These dimensions allow it to be incorporated into appropriately designed industrial electrical cabinets and machinery control panels.
ETE specifies Class E insulation, Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection. The transformer is designed to EN 61558-1 for continuous-rated control circuit operation, with a specified ambient temperature range of −10 to +35 °C.
The manufacturer's enclosure references for this model are EPH 2 or EPN 1. The final installation should provide suitable mechanical support, ventilation, electrical protection, conductor sizing and protective earthing. Transformer selection should also account for steady-state load, contactor inrush requirements and the specified 10% voltage regulation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 200 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Manufacturer part number | MV200P1S1 | |
| Product series | MV Multi-Voltage Series | |
| Product type | Multi-voltage control circuit transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 200 VA | |
| Primary terminals | 10/0/220/240 V | |
| Nominal primary voltage connections | 220 V AC or 240 V AC, subject to correct manufacturer-specified wiring | |
| Primary adjustment tap | 10 V — confirm exact connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary winding arrangement | 55/0/55 V centre-tapped winding | |
| Secondary output connections | 55 V AC or 110 V AC | |
| Calculated secondary current at 110 V | Approximately 1.82 A at 200 VA | |
| Theoretical secondary current at 55 V | Approximately 3.64 A based on 200 VA; permissible individual tap loading requires manufacturer confirmation | |
| Operating frequency | 50/60 Hz | |
| Insulation class | E | |
| Voltage regulation | 10% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding impregnation | Class H varnish | |
| Core earth connection | Provided | |
| Ambient operating temperature | −10 to +35 °C | |
| Design standard | EN 61558-1 | |
| Duty rating | Continuous | |
| Length | 96 mm | |
| Width | 87 mm | |
| Height | 103 mm | |
| Dimensions (L × W × H) | 96 × 87 × 103 mm | |
| Weight | 2.8 kg | |
| Enclosure references | EPH 2 or EPN 1 | |
| Manufacturer catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV200P1S1 is a 200 VA single-phase multi-voltage control transformer used to supply compatible industrial control circuits requiring nominal 55 V AC or 110 V AC connections. Typical applications include control panels, contactors, relays and machinery control equipment.
The transformer has 10/0/220/240 V primary terminals, including a 10 V adjustment tap. The exact terminal connections and adjustment method must be confirmed with ETE before installation or energisation.
Yes. Its 0/55/110 V secondary terminals provide nominal 55 V AC and 110 V AC connection options. The secondary is also described as a 55/0/55 V centre-tapped winding. The permissible loading of each tap should be checked against the manufacturer's instructions.
At its 200 VA rating and nominal 110 V AC output, the calculated secondary current is approximately 1.82 A. The connected load and any switching inrush requirements should be considered when selecting the transformer.
Dividing the full 200 VA rating by 55 V gives a theoretical current of approximately 3.64 A. However, this does not establish the allowable current from an individual 55 V half-winding. The permissible tap current and loading arrangement must be confirmed with ETE.
The 10 V adjustment tap is part of the transformer's multi-voltage primary winding arrangement. Its exact function and connection method must be confirmed with ETE rather than inferred solely from the terminal markings.
The transformer measures 96 × 87 × 103 mm (length × width × height) and weighs 2.8 kg.
The MV200P1S1 features Class E insulation and 10% voltage regulation. ETE also specifies Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection.
The manufacturer's specified enclosure references are EPH 2 or EPN 1. The final enclosure selection should provide appropriate mechanical support, ventilation and electrical protection for the intended installation.
The ETE MV200P1S1 combines a 200 VA rating, flexible 10/0/220/240 V primary terminals and a centre-tapped 55/0/55 V secondary winding in a compact industrial control transformer. With Class E insulation, 10% voltage regulation and EPH 2 or EPN 1 enclosure options, it is a practical choice for electrical panel builders, OEM machinery manufacturers and industrial maintenance engineers. The 10 V primary adjustment tap and permissible secondary tap loading should be confirmed with ETE before commissioning.