Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV2000P2S2 is a 2000 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, 10/0/220/240 V tapped secondary terminals, Class E insulation, 3% voltage regulation and an EPN 4 enclosure reference.
£206.55
The ETE MV2000P2S2 is a robust 2000 VA (2 kVA) single-phase multi-voltage control transformer designed to provide reliable AC power for industrial control circuits, electrical panels and automation equipment. As part of the ETE MV multi-voltage control transformer series, it offers flexible primary voltage connections and a tapped secondary winding for industrial applications requiring voltage conversion and electrical isolation.
The MV2000P2S2 features a 20/0/380/420 V primary terminal arrangement and a 10/0/220/240 V secondary terminal arrangement. The transformer is designed for compatible 380 V and 420 V AC primary supplies, with secondary connections providing 220 V and 240 V AC voltage options. Its tapped secondary configuration includes a 10 V adjustment tap, for which the correct terminal connections must be confirmed with ETE.
With a rated apparent power of 2000 VA, Class E insulation and 3% voltage regulation, the MV2000P2S2 provides dependable performance for industrial electrical installations. Its dimensions of 192 × 145 × 185 mm and weight of 18 kg make it suitable for integration into appropriately sized electrical control cabinets, switchgear assemblies and machinery panels.
Industrial control transformers convert an AC supply into a voltage suitable for electrical control equipment while providing electrical isolation between primary and secondary circuits. The ETE MV2000P2S2 is designed for compatible 380 V and 420 V AC primary supplies, with a tapped secondary arrangement supporting 220 V and 240 V AC output requirements.
The transformer incorporates a 10/0/220/240 V secondary terminal arrangement. Its tapped winding provides voltage selection flexibility for applications requiring different control supply voltages. The 10 V adjustment tap must be connected according to the manufacturer's specified terminal arrangement, and the correct connections should be confirmed with ETE before installation.
Based on the 2000 VA rating, the theoretical full-load secondary current is approximately 8.3 A at 240 V AC or 9.1 A at 220 V AC, assuming the full rated apparent power is available at the selected output. Actual permissible loading and terminal current ratings must follow ETE's specifications.
The transformer's 3% voltage regulation helps limit secondary voltage variation between operating load conditions. Correct primary and secondary connections, suitable overcurrent protection, appropriate conductor sizing and adequate installation clearances are essential for safe and reliable operation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 2000 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | MV Multi-Voltage Control Transformers | |
| Model | MV2000P2S2 | |
| Product type | Multi-voltage control transformer | |
| Rated apparent power | 2000 VA (2 kVA) | |
| Number of phases | Single-phase | |
| Primary terminal arrangement | 20/0/380/420 V | |
| Nominal primary voltage options | 380/420 V AC | |
| Secondary terminal arrangement | 10/0/220/240 V | |
| Secondary voltage options | 220/240 V AC | |
| Secondary connection type | Tapped output per manufacturer datasheet | |
| Adjustment tap | 10 V; confirm terminal connections with ETE | |
| Voltage regulation | 3% | |
| Insulation class | E | |
| Length | 192 mm | |
| Width | 145 mm | |
| Height | 185 mm | |
| Dimensions (L × W × H) | 192 × 145 × 185 mm | |
| Weight | 18 kg | |
| Enclosure reference | EPN 4 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV2000P2S2 is a single-phase industrial control transformer designed to convert compatible 380 V or 420 V AC supplies into 220 V or 240 V AC for electrical control circuits, industrial machinery and automation equipment.
The transformer has a rated apparent power of 2000 VA (2 kVA), making it suitable for industrial applications requiring a substantial AC control power supply.
The transformer features a 20/0/380/420 V primary terminal arrangement for compatible 380 V and 420 V AC supplies. The correct primary terminal selection must follow ETE's connection instructions.
The transformer has a 10/0/220/240 V secondary terminal arrangement supporting 220 V and 240 V AC output configurations. The exact connections must follow the manufacturer's tapped winding diagram.
The 10 V adjustment tap is part of the transformer's tapped voltage arrangement. Its correct terminal connections and permitted use must be confirmed with ETE to ensure the required secondary voltage is obtained safely.
Based on the 2000 VA rating, the theoretical full-load secondary current is approximately 8.3 A at 240 V AC or 9.1 A at 220 V AC, assuming the full transformer rating is available at the selected voltage. Actual permissible loading must comply with ETE's specifications.
The transformer measures 192 mm long × 145 mm wide × 185 mm high and weighs 18 kg.
The MV2000P2S2 features Class E insulation and 3% voltage regulation, supporting dependable operation in industrial electrical control applications.
The specified enclosure reference is EPN 4, identifying the corresponding ETE enclosure size for installations requiring additional protective housing.
ETE MV multi-voltage control transformers provide dependable voltage conversion solutions for industrial electrical installations. The MV2000P2S2 combines a 2000 VA rating, flexible 380/420 V primary connections, 220/240 V tapped secondary options, Class E insulation and 3% voltage regulation, making it a practical choice for industrial control panel builders, machinery manufacturers and electrical maintenance engineers.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.