ETE MV150P3S3 is a 150 VA single-phase multi-voltage control transformer with dual 120 V primary windings configurable for 120 V parallel or 240 V series operation, dual 12 V secondary windings configurable for 12 V parallel or 24 V series output, Class E insulation and 10% voltage regulation.
£32.93
The ETE MV150P3S3 is a versatile 150 VA single-phase multi-voltage control transformer featuring dual 120 V primary windings and dual 12 V secondary windings. Part of the ETE MV Multi-Voltage Series, it provides flexible electrical connections for industrial control panels, machinery, automation systems and OEM equipment requiring a nominal 12 V AC or 24 V AC output.
Its 0/120 V + 0/120 V primary terminals allow the two primary windings to be connected in parallel for a 120 V AC supply or in series for a 240 V AC supply. The 0/12 V + 0/12 V secondary terminals offer corresponding flexibility, with parallel connection providing 12 V AC and series connection providing 24 V AC.
With Class E insulation, 10% voltage regulation, dimensions of 96 × 76 × 103 mm and a weight of 2.3 kg, the MV150P3S3 provides a compact control power solution. The specified enclosure references are EPH 2 or EPN 1.
The ETE MV150P3S3 incorporates two separate 0/120 V primary windings, providing a flexible alternative to a transformer with a single fixed primary voltage. This design allows the transformer to operate from either a nominal 120 V AC or 240 V AC supply, depending on how the primary windings are connected.
For a nominal 120 V AC supply, the two primary windings are connected in parallel according to the manufacturer's wiring diagram. Correct winding polarity is essential to prevent opposing connections and potentially damaging circulating currents.
For a nominal 240 V AC supply, the two 120 V primary windings are connected in series, allowing the supply voltage to be shared across the windings. The correct series connection must be established using the manufacturer's terminal identification and connection instructions.
This dual-primary arrangement makes the MV150P3S3 suitable for electrical panel builders and OEM machinery manufacturers producing equipment for installations with different supply voltages. The primary winding configuration must be selected before energisation, and the manufacturer's wiring diagram must be followed.
The transformer features two separate 0/12 V secondary windings, enabling a nominal 12 V AC or 24 V AC output depending on the selected winding arrangement. This provides flexibility for industrial control circuits requiring different low-voltage AC supplies.
When the two 12 V secondary windings are connected correctly in parallel, the transformer provides a nominal 12 V AC output. Based on its total 150 VA rating, the calculated full-load output current is approximately 12.5 A.
Parallel connection requires the windings to have the correct polarity and matching voltages. Incorrect connections may cause excessive circulating current, overheating or transformer damage. The manufacturer's connection diagram should always be followed.
When the two secondary windings are connected in the correct series-aiding arrangement, their voltages combine to provide a nominal 24 V AC output. At 150 VA, the calculated full-load secondary current is approximately 6.25 A.
This configuration is suitable for appropriately rated 24 V AC control equipment, including relays, contactors, actuators and signalling devices. The total load, switching inrush and voltage regulation requirements should be considered during transformer selection.
Engineering note: The calculated output currents assume the full 150 VA rating is available in the selected winding configuration. The manufacturer's connection instructions, permissible winding loading and terminal ratings should be checked before installation.
With dimensions of 96 mm in length, 76 mm in width and 103 mm in height, the MV150P3S3 is well suited to installation within industrial control panels and electrical machinery cabinets. Its 2.3 kg weight allows it to be accommodated within appropriately designed mounting arrangements.
The transformer features Class E insulation, Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection. It is designed to EN 61558-1 for continuous-rated control circuit applications, with a specified ambient temperature range of −10 to +35 °C.
A DIN rail mounting option is available for this transformer size, providing flexibility for compatible panel installations. The specified enclosure references are EPH 2 or EPN 1. Suitable mechanical support, ventilation, conductor sizing, protective earthing and electrical protection should be incorporated into the complete installation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 150 VA | |
|---|---|---|
| Primary Voltage | 0/120V + 0/120V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Manufacturer part number | MV150P3S3 | |
| Product series | MV Multi-Voltage Series | |
| Product type | Multi-voltage control circuit transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 150 VA | |
| Primary terminals | 0/120 V + 0/120 V | |
| Number of primary windings | Two | |
| Individual primary winding voltage | 120 V AC | |
| Parallel primary connection | 120 V AC | |
| Series primary connection | 240 V AC | |
| Secondary terminals | 0/12 V + 0/12 V | |
| Number of secondary windings | Two | |
| Individual secondary winding voltage | 12 V AC | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Calculated secondary current at 12 V | Approximately 12.5 A, based on 150 VA with correctly connected parallel windings | |
| Calculated secondary current at 24 V | Approximately 6.25 A, based on 150 VA with correctly connected series windings | |
| Operating frequency | 50/60 Hz | |
| Insulation class | E | |
| Voltage regulation | 10% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding impregnation | Class H varnish | |
| Core earth connection | Provided | |
| Ambient operating temperature | −10 to +35 °C | |
| Design standard | EN 61558-1 | |
| Duty rating | Continuous | |
| Mounting | Panel mounting; DIN rail mounting option | |
| Length | 96 mm | |
| Width | 76 mm | |
| Height | 103 mm | |
| Dimensions (L × W × H) | 96 × 76 × 103 mm | |
| Weight | 2.3 kg | |
| Enclosure references | EPH 2 or EPN 1 | |
| Manufacturer catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV150P3S3 is a 150 VA single-phase multi-voltage control transformer used to supply compatible industrial control circuits requiring 12 V AC or 24 V AC. Its dual primary windings also support connection to either a 120 V AC or 240 V AC supply.
Yes. The transformer has two 0/120 V primary windings. Correctly connecting these windings in parallel provides 120 V AC primary operation, while connecting them in series provides 240 V AC primary operation. The manufacturer's winding polarity and wiring instructions must be followed.
The transformer has two 0/12 V secondary windings. Connecting them correctly in parallel provides a nominal 12 V AC output, while a correctly phased series connection provides a nominal 24 V AC output.
At the full 150 VA rating, the calculated secondary current is approximately 12.5 A at 12 V AC when the two secondary windings are correctly connected in parallel, subject to the manufacturer's permitted winding and terminal ratings.
With the secondary windings correctly connected in series, the 150 VA rating corresponds to a calculated nominal secondary current of approximately 6.25 A at 24 V AC.
Correct winding polarity is essential when connecting the primary or secondary windings in series or parallel. Incorrect connections can produce unintended voltages or excessive circulating currents. The manufacturer's terminal markings and wiring diagram must be followed before energising the transformer.
The transformer measures 96 × 76 × 103 mm (length × width × height) and weighs 2.3 kg.
The MV150P3S3 features Class E insulation and 10% voltage regulation. It also incorporates Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection.
The manufacturer's specified enclosure references are EPH 2 or EPN 1. The final enclosure and mounting arrangement should provide suitable ventilation, mechanical support and electrical protection.
The ETE MV150P3S3 offers a flexible industrial control power solution with a 150 VA rating, dual 120 V primary windings and dual 12 V secondary windings. Its configurable 120 V or 240 V input and 12 V or 24 V output arrangements, combined with Class E insulation, 10% voltage regulation and EPH 2 or EPN 1 enclosure options, make it a practical choice for industrial panel builders, OEM machinery manufacturers and automation engineers.