ETE MV150P2S3 is a 150 VA single-phase multi-voltage industrial control transformer with 20/0/380/420 V primary terminals and dual 0/12 V secondary windings. Its secondary output can be configured for 12 V AC in parallel or 24 V AC in series. The 20 V primary adjustment tap connections must be confirmed with ETE. Class E insulation, 10% voltage regulation, dimensions of 96 x 76 x 103 mm, weight of 2.3 kg and EPH 2 or EPN 1 enclosure references.
£32.93
The ETE MV150P2S3 is a 150 VA single-phase multi-voltage industrial control transformer featuring a tapped primary winding and two independent 12 V AC secondary windings. Manufactured by Eastern Transformers & Equipment (ETE), it forms part of the MV stock control transformer range, designed for electrical panel builders, OEM machinery manufacturers and industrial automation applications.
The transformer features 20/0/380/420 V primary terminals and 0/12 V + 0/12 V secondary terminals. Its secondary windings can be connected in parallel to provide a nominal 12 V AC output, or in series to provide a nominal 24 V AC output. This dual-output flexibility makes it a practical choice for machinery and control panels requiring different low-voltage AC configurations.
A key feature of the MV150P2S3 is its 20 V primary adjustment tap. This provides additional primary connection flexibility, but the precise wiring arrangement must be established from the manufacturer's documentation. Confirm the correct primary terminal connections, including the 20 V adjustment tap, with ETE before installation.
Rated at 150 VA, with Class E insulation and 10% voltage regulation, the MV150P2S3 is designed for compatible industrial control loads. Its dimensions are 96 × 76 × 103 mm, with a specified weight of 2.3 kg. The applicable enclosure references are EPH 2 or EPN 1.
The ETE MV150P2S3 has a primary terminal arrangement marked 20/0/380/420 V. These markings identify the manufacturer's tapped primary configuration, which is intended for compatible industrial AC supply arrangements.
The inclusion of a 20 V primary adjustment tap is an important distinguishing feature. It provides a means of selecting an appropriate primary winding connection, but the exact relationship between the terminals and the applied supply must be confirmed using the ETE wiring diagram.
The terminal markings should not be interpreted as four independent primary supply options. In particular, the 20 V terminal must not be treated as an independently rated primary input without explicit manufacturer confirmation.
Important: Before energising the transformer, confirm the intended primary voltage and terminal connections with ETE. Incorrect primary wiring may result in an unsuitable secondary voltage, excessive winding current or transformer damage.
The MV150P2S3 incorporates two separate 0/12 V secondary windings. These provide flexibility for industrial control circuits requiring either a nominal 12 V AC or 24 V AC supply.
When the two secondary windings are correctly connected in parallel, the output remains at a nominal 12 V AC. The windings share the connected load, allowing their current capabilities to be combined within the transformer's overall 150 VA rating.
Correct winding polarity is essential. The secondary windings must be connected in phase according to the manufacturer's wiring diagram. An incorrect parallel connection can create excessive circulating current and damage the transformer.
When the two secondary windings are correctly connected in series, their nominal voltages add together to provide 24 V AC.
The winding connections must be arranged so that the voltages add rather than oppose one another. The manufacturer's terminal identification and connection diagram should always be followed.
The ability to select either 12 V AC or 24 V AC makes the MV150P2S3 suitable for consideration in machinery and control panel designs that use different low-voltage AC control equipment.
The 150 VA apparent power rating applies to the complete transformer, not independently to each secondary winding. The nominal current corresponding to each output configuration can be calculated using:
Current (A) = Apparent power (VA) ÷ Secondary voltage (V)
For a correctly configured 12 V AC parallel output:
150 VA ÷ 12 V = 12.50 A
This is the calculated total current corresponding to the transformer rating. It assumes correct parallel winding operation and does not constitute a separate manufacturer-published terminal current rating.
For a correctly configured 24 V AC series output:
150 VA ÷ 24 V = 6.25 A
This is the calculated nominal current corresponding to the transformer rating in the series configuration.
The selected transformer must be suitable for the total connected apparent power and the operating characteristics of the load. Where electromagnetic contactors, relays or other inductive devices are used, their energisation and inrush requirements should also be considered.
The ETE MV150P2S3 has a specified 10% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under defined operating or test conditions.
Consequently, the actual secondary voltage may vary as the load changes. Electrical designers should consider this characteristic when selecting equipment with defined operating voltage tolerances.
The MV150P2S3 is an AC transformer rather than an electronic voltage regulator. Its 12 V AC and 24 V AC ratings are nominal output values associated with the correct winding configurations.
The ETE MV150P2S3 should be installed by a suitably qualified person using the manufacturer's connection diagram. Before installation, confirm the available primary supply, required secondary output, connected load and intended winding arrangement.
Primary wiring: The 20/0/380/420 V terminals include a 20 V adjustment tap. Confirm the correct primary terminal connections with ETE before energising the transformer.
Secondary wiring: The two 0/12 V windings must be connected in parallel for 12 V AC or in series for 24 V AC. Correct winding polarity is essential in both configurations.
The installation must incorporate suitable primary and secondary circuit protection, appropriate conductor sizing, protective earthing, ventilation and secure mechanical mounting. The EPH 2 or EPN 1 enclosure references should be checked against the intended installation environment and mechanical requirements.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 150 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model / SKU | MV150P2S3 | |
| Product type | Industrial multi-voltage control transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 150 VA | |
| Primary terminal configuration | 20/0/380/420 V | |
| Primary adjustment tap | 20 V | |
| Primary connection note | Confirm terminal connections with ETE | |
| Secondary terminal configuration | 0/12 V + 0/12 V | |
| Secondary winding arrangement | Two nominal 12 V AC windings | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Output connection | 12 V parallel or 24 V series | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | E | |
| Voltage regulation | 10% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding treatment | Class H varnish impregnation | |
| Core earthing | Core earth connection | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Design standard | EN 61558-1 | |
| Calculated total secondary current at 12 V AC | Approximately 12.50 A with correctly connected parallel windings | |
| Calculated secondary current at 24 V AC | Approximately 6.25 A with correctly connected series windings | |
| Length | 96 mm | |
| Width | 76 mm | |
| Height | 103 mm | |
| Dimensions (L × W × H) | 96 × 76 × 103 mm | |
| Weight | 2.3 kg | |
| Enclosure reference | EPH 2 or EPN 1 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV150P2S3 is a 150 VA single-phase multi-voltage control transformer designed for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. Its dual secondary windings can provide either 12 V AC or 24 V AC.
The primary terminals are marked 20/0/380/420 V. The correct terminal connections, including the 20 V adjustment tap, must be confirmed with ETE.
The transformer includes a 20 V primary adjustment tap as part of its tapped primary arrangement. Its exact function and correct connections must be confirmed using the manufacturer's documentation.
The secondary terminals are specified as 0/12 V + 0/12 V, representing two separate nominal 12 V AC windings.
Yes. The two secondary windings can be connected in parallel to provide a nominal 12 V AC output, provided the correct winding polarity and manufacturer's wiring instructions are followed.
Yes. The two secondary windings can be connected in series to provide a nominal 24 V AC output, with the correct winding polarity so the voltages add together.
The ETE MV150P2S3 has a rated apparent power of 150 VA. This is the rating of the complete transformer rather than a separate 150 VA rating for each secondary winding.
At a nominal 12 V AC output, the 150 VA rating corresponds to approximately 12.50 A total when the secondary windings are correctly connected in parallel. This is a calculated value for load assessment.
At a nominal 24 V AC output, the 150 VA rating corresponds to approximately 6.25 A when the secondary windings are correctly connected in series. This is a calculated value for load assessment.
The MV150P2S3 has a specified Class E insulation system.
The ETE MV150P2S3 has a specified 10% voltage regulation. This should be considered when assessing the operating voltage requirements of connected equipment.
The transformer measures 96 mm long, 76 mm wide and 103 mm high, with a specified weight of 2.3 kg.
The specified enclosure references are EPH 2 or EPN 1. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
Correct winding polarity is essential when connecting the two 12 V secondary windings in series or parallel. Incorrect connections can cause opposing voltages, excessive circulating current or transformer damage. Always follow the ETE connection diagram.
No. The ETE MV150P2S3 provides a nominal 12 V AC or 24 V AC output, depending on the secondary configuration. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
The MV150P2S3 has a 20/0/380/420 V primary terminal arrangement that includes a 20 V adjustment tap. Confirming the connection diagram with ETE helps prevent incorrect wiring and ensures the intended operating voltage is selected.
When selecting the ETE MV150P2S3, confirm the intended primary connection using ETE's technical documentation. The 20 V primary adjustment tap must not be connected based on assumptions about the terminal markings.
Next, determine whether the connected equipment requires 12 V AC or 24 V AC. The secondary windings must then be configured correctly in parallel or series, with the appropriate winding polarity.
The transformer's 150 VA rating, 10% voltage regulation, Class E insulation, physical dimensions and enclosure requirements should be considered as part of the overall electrical design.
The ETE MV150P2S3 combines a 150 VA rating with a tapped primary winding and dual 12 V secondary windings. Its selectable 12 V AC parallel or 24 V AC series output, Class E insulation, 10% voltage regulation and compact construction make it a practical option for industrial control panels, OEM machinery and automation systems requiring flexible AC control power. Always confirm the 20 V primary adjustment tap connections with ETE.