ETE MV150P2S2 is a 150 VA single-phase multi-voltage industrial control transformer with 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals. It has a tapped output with a 10 V adjustment tap requiring connection confirmation with ETE, Class E insulation, 10% voltage regulation, dimensions of 96 x 76 x 103 mm, weight of 2.3 kg and EPH 2 or EPN 1 enclosure references.
£32.93
The ETE MV150P2S2 is a compact 150 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, OEM machinery and automation systems requiring flexible AC voltage connections. Part of the ETE MV multi-voltage stock control transformer range, it features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, allowing electrical designers to select the appropriate connections for compatible industrial control circuits.
Unlike a conventional fixed-voltage transformer, the MV150P2S2 incorporates a multi-tapped primary and secondary arrangement. Its primary terminal markings accommodate different supply configurations, while its secondary winding provides a tapped AC output that must be connected according to the manufacturer's datasheet.
The secondary terminal arrangement includes a 10 V adjustment tap. This is an important consideration when specifying or installing the transformer: the exact terminal connections must be confirmed with ETE, particularly when the adjustment tap is required. The markings alone should not be used to infer every available voltage combination.
With a rated apparent power of 150 VA, Class E insulation and 10% voltage regulation, the ETE MV150P2S2 provides a practical solution for compatible industrial control loads. It measures 96 × 76 × 103 mm and weighs 2.3 kg, making it suitable for electrical cabinets and machinery panels where available space must be considered.
The transformer is listed in the ETE Stock Control Transformer Range, March 2026, with specified enclosure references of EPH 2 or EPN 1.
The ETE MV150P2S2 uses a tapped primary winding arrangement identified by the terminals 20/0/380/420 V. This configuration is intended to accommodate compatible industrial AC supply arrangements, with the actual connection determined by the manufacturer's wiring diagram.
The secondary terminals are marked 10/0/220/240 V. Rather than specifying one fixed output connection, ETE identifies this model as having a tapped output per datasheet. The terminal arrangement offers flexibility, but the exact output voltage depends on the approved primary and secondary connections.
The 10 V adjustment tap requires particular attention. It should not automatically be interpreted as a standalone 10 V power output or assumed to provide a particular voltage correction without confirmation. The correct function, terminal combinations and connection sequence should be verified directly with ETE.
This multi-voltage arrangement can be valuable for electrical panel builders and OEM machinery manufacturers who need to accommodate differing supply or control voltage requirements. However, the transformer's flexibility does not eliminate the need for careful voltage selection and verification.
The MV150P2S2 has a rated apparent power of 150 VA. For a single-phase transformer, the relationship between apparent power, nominal voltage and current can be expressed as:
Current (A) = Apparent power (VA) ÷ Voltage (V)
For example, if the manufacturer's approved connection provides a nominal 220 V AC output, a 150 VA rating corresponds to a calculated current of approximately 0.68 A.
If the approved connection provides a nominal 240 V AC output, the corresponding calculated current is approximately 0.63 A.
These values are mathematical calculations for the stated nominal voltages. They do not independently establish the correct terminal connections, permissible current on every tap or the manufacturer's protection requirements.
When selecting the transformer, engineers should assess the combined apparent power of connected equipment, operating voltage tolerances and any short-duration starting or inrush demands. The specified 10% voltage regulation must also be considered because secondary voltage can change with loading conditions.
The ETE MV150P2S2 has a specified 10% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under defined test conditions.
This means the actual output voltage may differ from the nominal voltage as the connected load changes. For control equipment with a narrow operating voltage tolerance, the regulation characteristic should be considered alongside primary supply variation and the selected secondary connection.
Voltage regulation is not the same as automatic electronic voltage stabilisation. The MV150P2S2 is an AC transformer, and its output should not be assumed to remain perfectly constant under all operating conditions.
Before installing the ETE MV150P2S2, confirm the available AC supply voltage, the required secondary voltage and the total connected load. The transformer must be connected using the correct primary and secondary terminals for the intended configuration.
Important connection note: The primary terminal markings 20/0/380/420 V and secondary terminal markings 10/0/220/240 V must be interpreted using the ETE wiring diagram. Confirm the 10 V adjustment tap connections directly with ETE before energising the transformer.
Suitable primary and secondary overcurrent protection, conductor sizing, protective earthing where required, ventilation and secure mechanical mounting should be considered as part of the installation design.
The specified EPH 2 or EPN 1 enclosure references should be checked against the installation requirements. The enclosure reference alone does not establish an environmental protection rating or confirm suitability for every installation location.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 150 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Control Transformer Range | |
| Model / SKU | MV150P2S2 | |
| Product type | Multi-voltage industrial control transformer | |
| Transformer configuration | Multi-tapped primary and secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 150 VA | |
| Primary terminals | 20/0/380/420 V | |
| Secondary terminals | 10/0/220/240 V | |
| Output connection | Tapped output per datasheet | |
| Adjustment tap | 10 V adjustment tap | |
| Connection note | Confirm terminal connections with ETE | |
| Insulation class | E | |
| Voltage regulation | 10% | |
| Calculated current at a nominal 220 V AC output | Approximately 0.68 A, based on 150 VA | |
| Calculated current at a nominal 240 V AC output | Approximately 0.63 A, based on 150 VA | |
| Length | 96 mm | |
| Width | 76 mm | |
| Height | 103 mm | |
| Dimensions (L × W × H) | 96 × 76 × 103 mm | |
| Weight | 2.3 kg | |
| Enclosure reference | EPH 2 or EPN 1 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV150P2S2 is a 150 VA single-phase multi-voltage control transformer intended for compatible industrial electrical control panels, OEM machinery and auxiliary circuits. Its tapped primary and secondary arrangements provide flexibility for suitable AC voltage connections.
The primary terminals are specified as 20/0/380/420 V. The correct connections must be selected according to the available supply voltage and the ETE wiring diagram.
The secondary terminals are specified as 10/0/220/240 V. The transformer has a tapped output, and the appropriate terminal combinations must be confirmed against the ETE datasheet.
No. The MV150P2S2 is specified with a tapped output per datasheet, rather than one fixed output connection. The resulting voltage depends on the approved primary and secondary terminal connections.
The MV150P2S2 includes a 10 V adjustment tap in its secondary terminal arrangement. Its exact function and correct terminal connections must be confirmed with ETE before installation.
Do not assume the 10 V adjustment tap is a standalone load output. The manufacturer identifies it as an adjustment tap, and the correct connections and permissible use must be confirmed with ETE.
The ETE MV150P2S2 has a rated apparent power of 150 VA. Connected equipment must remain within the applicable transformer rating and operating limits.
At a nominal 220 V AC, a 150 VA rating corresponds to approximately 0.68 A. This is a calculated value and does not establish which terminal combination should be used.
At a nominal 240 V AC, a 150 VA rating corresponds to approximately 0.63 A. The correct output connection and permissible loading must still be verified against the manufacturer's documentation.
The MV150P2S2 has a specified Class E insulation system.
The ETE MV150P2S2 has a specified 10% voltage regulation. This should be considered when assessing the operating voltage requirements of connected control equipment.
The transformer measures 96 mm long, 76 mm wide and 103 mm high, with a specified weight of 2.3 kg.
The specified enclosure references are EPH 2 or EPN 1. Final enclosure selection should consider the installation environment, dimensions, ventilation and applicable electrical requirements.
No. The ETE MV150P2S2 is an AC control transformer. Equipment requiring DC power needs an appropriate DC power supply or suitable rectification and conditioning equipment.
The MV150P2S2 has 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, including a 10 V adjustment tap. Confirming the ETE connection diagram helps ensure that the intended voltage is obtained without making unsafe assumptions about the winding taps.
When specifying the ETE MV150P2S2, verify the intended primary supply and secondary output using the manufacturer's approved wiring configuration. The 150 VA rating must be sufficient for the connected control equipment, with suitable consideration given to load characteristics and inrush demands.
Its Class E insulation, 10% voltage regulation, 96 × 76 × 103 mm dimensions and 2.3 kg weight should be considered during electrical and mechanical design. Where an enclosure is required, check the specified EPH 2 or EPN 1 references against the installation requirements.
Most importantly, the 10 V adjustment tap and all other terminal connections must be verified with ETE before installation.
The ETE MV150P2S2 combines a 150 VA rating with a multi-tapped primary and secondary arrangement, Class E insulation and 10% voltage regulation. Its compact dimensions and specified EPH 2 or EPN 1 enclosure references make it a practical option for compatible industrial control applications requiring flexible AC voltage connections. Always confirm the intended terminal configuration, including the 10 V adjustment tap, with ETE.