ETE MV1500P2S2 Multi-Voltage Control Transformer 1500VA 20/0/380/420V to 10/0/220/240V

ETE MV1500P2S2 Multi-Voltage Control Transformer 1500VA 20/0/380/420V to 10/0/220/240V

ETE MV1500P2S2 is a 1500 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, 10/0/220/240 V tapped secondary terminals, a 10 V adjustment tap requiring ETE connection confirmation, Class E insulation and 4% voltage regulation.

SKU: MV1500P2S2MPN: MV1500P2S2
Price
List Price £201.00 ex VAT
Your Price (ex VAT) Save 25%
£150.75 25% OFF
You save £50.25 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £150.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£150.75

Why Choose the ETE MV1500P2S2 Multi-Voltage Control Transformer?

The ETE MV1500P2S2 is a robust 1500 VA (1.5 kVA) single-phase multi-voltage control transformer designed to provide reliable electrical isolation and adaptable AC control power for industrial machinery, electrical control panels and automation systems. Part of the ETE MV Multi-Voltage transformer series, it features primary terminals marked 20/0/380/420 V and secondary terminals marked 10/0/220/240 V, providing flexible voltage connection options for compatible industrial installations.

Manufactured by Eastern Transformers & Equipment (ETE), the MV1500P2S2 incorporates nominal 380 V and 420 V primary connections and a tapped secondary winding arrangement with 220 V and 240 V terminals. The transformer also features a 10 V adjustment tap, for which the correct terminal connections must be confirmed with ETE. The primary terminal arrangement additionally includes a terminal marked 20 V, with the appropriate connections to be determined from the manufacturer's wiring information.

With a rated capacity of 1500 VA, Class E insulation and 4% voltage regulation, the MV1500P2S2 offers substantial control power capability for industrial applications. Measuring 150 × 151 × 145 mm and weighing 14.2 kg, it is suitable for integration into appropriately engineered electrical equipment. The manufacturer's specified enclosure reference is EPN 4.

Key Advantages

  • 1500 VA (1.5 kVA) rated capacity supports substantial industrial control circuit loads.
  • Multi-voltage primary terminals marked 20/0/380/420 V provide flexible supply connection options.
  • 380 V and 420 V primary connections accommodate compatible industrial electrical supplies.
  • Tapped secondary winding provides 220 V and 240 V terminal options.
  • 10 V adjustment tap provides additional connection flexibility, subject to confirmation with ETE.
  • Electrical isolation between the primary supply and secondary control circuits.
  • 4% voltage regulation supports consistent secondary voltage performance under changing load conditions.
  • Class E insulation provides a defined insulation classification for industrial transformer applications.
  • Single-phase construction supports integration into compatible machinery and control equipment.
  • EPN 4 enclosure reference assists with selection of a suitable protective enclosure.

Key Features

  • ETE MV Multi-Voltage transformer series.
  • 1500 VA (1.5 kVA) rated apparent power.
  • Single-phase control transformer configuration.
  • Primary terminals: 20/0/380/420 V.
  • Nominal primary voltage connections: 380 V and 420 V.
  • Additional primary terminal: 20 V, with connections to be verified against ETE documentation.
  • Secondary terminals: 10/0/220/240 V.
  • Nominal secondary voltage terminals: 220 V and 240 V.
  • 10 V adjustment tap; confirm terminal connections with ETE.
  • Tapped secondary output configured according to the manufacturer's datasheet.
  • 4% voltage regulation.
  • Class E insulation system.
  • EPN 4 enclosure reference.
  • 150 × 151 × 145 mm overall dimensions.
  • 14.2 kg transformer weight.

Flexible Primary Connections for Industrial Electrical Supplies

The ETE MV1500P2S2 features primary terminals marked 20/0/380/420 V, providing nominal 380 V and 420 V connection options for compatible industrial power systems.

This arrangement is useful for electrical panel builders, OEM machinery manufacturers and control system integrators working with equipment designed for different nominal supply voltages. Selecting the appropriate primary connection helps match the transformer to the available electrical supply.

The primary terminal arrangement also includes a terminal marked 20 V. Its exact connection function must be established from ETE's wiring instructions rather than assumed from the terminal marking alone.

The transformer uses fixed winding connections rather than automatic voltage selection. The correct terminals must be identified before energising the equipment, with appropriate primary circuit protection and installation precautions.

Tapped 220 V and 240 V Secondary Connections

The MV1500P2S2 incorporates a tapped secondary winding with terminals marked 10/0/220/240 V. The manufacturer's specification identifies the output arrangement as tapped output per datasheet, allowing the correct secondary connection to be selected for the intended control circuit.

  • 220 V terminal: Provides a nominal 220 V connection option when wired according to the manufacturer's instructions.
  • 240 V terminal: Provides a nominal 240 V connection option when wired according to the manufacturer's instructions.
  • 10 V adjustment tap: Provides an additional winding connection whose exact function and terminal arrangement must be confirmed with ETE.

The 10 V adjustment tap must not be assumed to provide an independent 10 V supply or a particular voltage correction without confirmation of the manufacturer's wiring arrangement. The correct output connections should be established from the relevant ETE datasheet before installation.

The 1500 VA rating applies to the transformer as a whole. Connected loads must remain within the applicable transformer and winding limits, with appropriate circuit protection, conductor sizing and consideration of equipment starting currents.

Reliable Industrial Control Power with 4% Voltage Regulation

The ETE MV1500P2S2 has a specified 4% voltage regulation, describing the change in secondary voltage between the manufacturer's defined loading conditions. This characteristic is useful when selecting a control transformer for industrial equipment where the connected electrical load may vary during operation.

Combined with its Class E insulation system, 1.5 kVA rated capacity and multi-voltage winding arrangement, the transformer provides a practical solution for industrial control applications requiring isolated AC power and selectable voltage connections.

Typical Applications

  • Industrial electrical control panels requiring nominal 220 V AC or 240 V AC control power.
  • Machinery control systems operating from compatible 380 V or 420 V AC supplies.
  • Industrial automation and machine control equipment.
  • Contactor, relay and control device circuits within the transformer rating.
  • OEM machinery and industrial equipment manufacturing.
  • Manufacturing plant and production line control systems.
  • Industrial process control installations.
  • Electrical switchgear and control panel integration.
  • Applications requiring a 1.5 kVA single-phase control transformer with tapped voltage connections.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 1500 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 10/0/220/240V
Phase Single Phase
Manufacturer Eastern Transformers & Equipment (ETE)
Series MV Multi-Voltage Transformers
Model MV1500P2S2
Product type Multi-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 1500 VA (1.5 kVA)
Primary terminals 20/0/380/420 V
Primary nominal voltage connections 380 V and 420 V
Additional primary terminal marking 20 V
Secondary terminals 10/0/220/240 V
Secondary nominal voltage terminals 220 V and 240 V
Output connection Tapped output per datasheet
Adjustment tap 10 V; confirm terminal connections with ETE
Voltage regulation 4%
Insulation class E
Enclosure reference EPN 4
Length 150 mm
Width 151 mm
Height 145 mm
Dimensions (L × W × H) 150 × 151 × 145 mm
Weight 14.2 kg
Manufacturer range ETE stock control transformer range
Specification reference ETE stock control transformer price list, March 2026

Frequently Asked Questions

What is the ETE MV1500P2S2 used for?

The ETE MV1500P2S2 is a 1500 VA single-phase multi-voltage control transformer used to provide isolated AC control power for compatible industrial machinery, electrical panels and automation systems.

What primary input voltages does the MV1500P2S2 support?

The transformer has primary terminals marked 20/0/380/420 V, incorporating nominal 380 V and 420 V connections. The correct wiring arrangement, including the additional 20 V terminal, should be verified against ETE's documentation.

What is the purpose of the 20 V primary terminal?

The primary terminal arrangement includes a terminal marked 20 V. The manufacturer's supplied specification does not define its exact connection function, so the correct arrangement must be confirmed with ETE before installation.

What secondary output voltages are available?

The MV1500P2S2 has secondary terminals marked 10/0/220/240 V, incorporating nominal 220 V and 240 V output connections. The output must be wired according to the manufacturer's datasheet.

What is the purpose of the 10 V adjustment tap?

The 10 V adjustment tap provides an additional winding connection. Its precise function and correct terminal arrangement must be confirmed with ETE, and it should not be assumed to provide an independent 10 V output.

Can the MV1500P2S2 provide both 220 V AC and 240 V AC?

The transformer has secondary terminals marked for nominal 220 V and 240 V connections. The appropriate output is selected using the manufacturer's specified tapped winding arrangement rather than by assuming two independent full-capacity secondary outputs.

What is the power rating of the ETE MV1500P2S2?

The transformer has a rated apparent power of 1500 VA (1.5 kVA), suitable for compatible industrial control loads within its specified capacity.

What is the voltage regulation of the MV1500P2S2?

The transformer has a specified 4% voltage regulation, describing the change in secondary voltage between the manufacturer's defined loading conditions.

What are the dimensions, weight and insulation class?

The MV1500P2S2 measures 150 × 151 × 145 mm (L × W × H), weighs 14.2 kg and features a Class E insulation system.

What enclosure reference is specified for the MV1500P2S2?

The manufacturer's specified enclosure reference is EPN 4. This reference can be used when confirming a suitable protective enclosure arrangement with ETE.

Trusted ETE Transformer Engineering

ETE MV multi-voltage transformers provide flexible winding connections, dependable electrical isolation and robust control power solutions for industrial applications. The MV1500P2S2 combines a 1500 VA rating, 20/0/380/420 V primary terminals and 10/0/220/240 V tapped secondary terminals with Class E insulation and 4% voltage regulation, making it a practical choice for professional electrical panel builders and industrial equipment manufacturers.