ETE MV1500P1S1 is a 1500 VA (1.5 kVA) single-phase multi-voltage industrial control transformer with 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. It provides selectable nominal 55 V AC or 110 V AC output connections. The 10 V primary adjustment tap connections must be confirmed with ETE. Class E insulation, 4% voltage regulation, dimensions of 150 x 151 x 145 mm, weight of 14.2 kg and EPN 4 enclosure reference.
£150.75
The ETE MV1500P1S1 is a 1500 VA (1.5 kVA) single-phase multi-voltage industrial control transformer featuring a tapped primary winding and selectable 55 V AC or 110 V AC secondary output. Part of the ETE MV stock control transformer range, this model provides a higher-capacity AC control power solution for compatible industrial electrical panels, OEM machinery and automation systems.
The transformer features 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. Its tapped secondary winding allows the appropriate nominal output voltage to be selected for equipment requiring either 55 V AC or 110 V AC.
The MV1500P1S1 incorporates a 10 V primary adjustment tap. The precise function of this tap and its approved terminal connections must be confirmed with ETE before installation. The primary terminal markings alone must not be treated as a complete wiring diagram.
With a substantial 1500 VA apparent power rating, Class E insulation and 4% voltage regulation, the MV1500P1S1 is suitable for consideration in industrial control circuits with appropriately rated loads. Its dimensions are 150 × 151 × 145 mm, with a specified weight of 14.2 kg.
The transformer has an associated EPN 4 enclosure reference and is listed as MV1500P1S1 in the ETE Stock Control Transformer Range, March 2026.
The ETE MV1500P1S1 has a tapped primary winding identified by the terminals 10/0/220/240 V. This arrangement provides primary voltage connection options that must be selected according to the manufacturer's approved wiring instructions.
The 10 V primary adjustment tap forms part of the primary winding arrangement. Its exact purpose and permissible terminal combinations must be confirmed with ETE before energising the transformer.
The 10 V marking must not be interpreted as evidence of an independently rated 10 V supply input. Equally, the presence of 220 V and 240 V terminal markings does not remove the need to verify the correct primary connections.
Electrical designers and installers should confirm the available supply voltage, intended primary terminal selection and expected secondary output against the ETE connection diagram. Incorrect primary wiring may result in unsuitable output voltage or transformer damage.
The MV1500P1S1 features a tapped secondary winding identified by the terminals 0/55/110 V. This provides two nominal output voltage options for compatible industrial control equipment.
The 55 V AC secondary tap allows the transformer to provide a nominal 55 V AC output for equipment designed to operate at that voltage.
This option may be appropriate for specialist industrial machinery, replacement applications and control circuits that specifically require a 55 V AC supply.
The permissible loading of the 55 V tap and its approved terminal connection should be verified against ETE's technical documentation.
The 110 V AC secondary tap provides a nominal 110 V AC output for compatible industrial control systems, including appropriately rated contactors, relays and auxiliary control equipment.
The transformer's 1500 VA rating offers capacity for suitable connected loads, subject to the manufacturer's applicable terminal and winding ratings.
The 55 V and 110 V options are taps on the specified secondary winding, not two independent 1500 VA outputs. Any simultaneous use of multiple secondary taps must be confirmed with ETE, including permissible combined loading.
The ETE MV1500P1S1 has a rated apparent power of 1500 VA (1.5 kVA). The current corresponding to a nominal secondary voltage can be calculated using:
Current (A) = Apparent power (VA) ÷ Secondary voltage (V)
For a nominal 55 V AC output:
1500 VA ÷ 55 V = approximately 27.27 A
This is the mathematical current corresponding to the complete 1500 VA rating at 55 V AC. It does not independently establish the manufacturer's permissible current rating for the 55 V tap.
For a nominal 110 V AC output:
1500 VA ÷ 110 V = approximately 13.64 A
This is the mathematical current corresponding to the complete 1500 VA rating at 110 V AC.
The overall 1500 VA rating must not be counted separately for each secondary tap. Engineers should verify permissible tap loading, connected equipment demand, starting and inrush requirements, and suitable circuit protection before installation.
The ETE MV1500P1S1 has a specified 4% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under defined conditions.
The actual secondary voltage may vary with the primary supply and connected load. The nominal 55 V AC and 110 V AC outputs should therefore not be interpreted as electronically stabilised voltages.
The 4% regulation characteristic should be considered when selecting the transformer for control equipment with defined operating voltage tolerances. It is not the same as a guaranteed ±4% output voltage tolerance.
Before installing the ETE MV1500P1S1, verify the available primary supply, intended secondary output voltage, connected apparent power and correct terminal connections.
Primary wiring: The 10/0/220/240 V terminal arrangement includes a 10 V adjustment tap. Confirm the correct primary connections with ETE before energising the transformer.
Secondary wiring: The 0/55/110 V terminals provide nominal 55 V AC or 110 V AC output options. Select the correct tap according to the manufacturer's approved wiring diagram and the connected equipment's voltage requirements.
Mechanical installation: The transformer weighs 14.2 kg. Its supporting structure, mounting arrangement and installation method should be appropriate for this weight and the intended operating environment.
Suitable primary and secondary circuit protection, conductor sizing, protective earthing where applicable, ventilation and secure mechanical mounting should be incorporated into the installation design.
The specified EPN 4 enclosure reference should be checked against the intended installation requirements. This reference alone does not establish an enclosure protection rating or confirm that an enclosure is included.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 1500 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model / SKU | MV1500P1S1 | |
| Product type | Industrial multi-voltage control transformer | |
| Transformer configuration | Tapped primary and tapped secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 1500 VA | |
| Equivalent apparent power | 1.5 kVA | |
| Primary terminals | 10/0/220/240 V | |
| Primary adjustment tap | 10 V | |
| Primary connection note | Confirm connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary output options | 55 V AC or 110 V AC | |
| Output connection | 55 V or 110 V taps | |
| Insulation class | E | |
| Voltage regulation | 4% | |
| Calculated current at nominal 55 V AC | Approximately 27.27 A, based on 1500 VA | |
| Calculated current at nominal 110 V AC | Approximately 13.64 A, based on 1500 VA | |
| Length | 150 mm | |
| Width | 151 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 151 × 145 mm | |
| Weight | 14.2 kg | |
| Enclosure reference | EPN 4 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV1500P1S1 is a 1500 VA single-phase multi-voltage control transformer intended for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. It features a tapped primary and selectable 55 V AC or 110 V AC secondary output.
The MV1500P1S1 has a rated apparent power of 1500 VA, equivalent to 1.5 kVA.
The primary terminals are specified as 10/0/220/240 V. The correct connections, including the 10 V adjustment tap, must be confirmed with ETE.
The MV1500P1S1 includes a 10 V primary adjustment tap as part of its tapped primary winding. Its exact use and approved terminal connections must be confirmed with ETE before installation.
The secondary terminals are specified as 0/55/110 V, providing nominal 55 V AC and 110 V AC output options using the appropriate connections.
Yes. The MV1500P1S1 has a 55 V AC secondary tap. The correct terminal connection and permissible loading should be checked against ETE's technical documentation.
Yes. The MV1500P1S1 has a 110 V AC secondary tap for compatible industrial control equipment. The correct terminal connection must follow the manufacturer's instructions.
At a nominal 55 V AC output, 1500 VA corresponds mathematically to approximately 27.27 A. The permissible loading of the 55 V tap must still be verified against the manufacturer's documentation.
At a nominal 110 V AC output, 1500 VA corresponds mathematically to approximately 13.64 A. This calculated value is for load assessment and does not replace the manufacturer's terminal ratings.
Do not assume that both secondary taps can supply independent loads simultaneously. Any permitted simultaneous loading and combined current limits must be confirmed with ETE.
The MV1500P1S1 has a specified Class E insulation system.
The ETE MV1500P1S1 has a specified 4% voltage regulation. This describes a load-related voltage characteristic and should not be interpreted as a guaranteed ±4% output voltage tolerance.
The transformer measures 150 mm long, 151 mm wide and 145 mm high, with a specified weight of 14.2 kg.
The specified enclosure reference is EPN 4. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
No. The ETE MV1500P1S1 is an AC control transformer providing nominal 55 V AC or 110 V AC output connections. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
The MV1500P1S1 has a 10/0/220/240 V primary terminal arrangement incorporating a 10 V adjustment tap. Confirming the ETE connection diagram helps prevent incorrect wiring and ensures the intended primary configuration is selected.
When specifying the ETE MV1500P1S1, first confirm that the intended primary supply can be accommodated using the manufacturer's approved terminal arrangement. The 10 V adjustment tap must be connected only in accordance with ETE's instructions.
Next, confirm whether the connected equipment requires a nominal 55 V AC or 110 V AC output. Assess the total connected apparent power, any inrush requirements and the permissible loading of the selected secondary tap.
The transformer's 1500 VA rating, 4% voltage regulation, Class E insulation, 150 × 151 × 145 mm dimensions and 14.2 kg weight should all be considered during electrical and mechanical design.
The ETE MV1500P1S1 combines a 1500 VA (1.5 kVA) rating with a tapped 10/0/220/240 V primary and selectable 55 V AC or 110 V AC secondary connections. Its Class E insulation, 4% voltage regulation and EPN 4 enclosure reference make it a practical option for compatible higher-capacity industrial control applications. Always confirm the 10 V primary adjustment tap connections with ETE.