ETE MV100P3S3 is a 100 VA single-phase multi-voltage industrial control transformer with dual 0/120 V primary windings for 120 V parallel or 240 V series connection and dual 0/12 V secondary windings for 12 V parallel or 24 V series output. It features Class E insulation, 12% voltage regulation, dimensions of 85 x 70 x 93 mm, weight of 1.5 kg and EPH 1 or EPN 1 enclosure references.
£26.10
The ETE MV100P3S3 is a versatile 100 VA single-phase multi-voltage industrial control transformer designed to accommodate 120 V AC or 240 V AC primary supplies and provide a selectable 12 V AC or 24 V AC secondary output. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the established ETE MV multi-voltage stock control transformer range, developed for electrical panel builders, machinery manufacturers and industrial automation applications requiring flexible voltage configurations.
The MV100P3S3 features two 0/120 V primary windings and two 0/12 V secondary windings. By connecting the primary windings in parallel, the transformer can operate from a nominal 120 V AC supply. Connecting the primary windings in series allows operation from a nominal 240 V AC supply. This arrangement enables a single transformer model to accommodate two commonly used control supply voltages.
On the secondary side, the two 12 V windings provide additional flexibility. When connected correctly in parallel, they provide a nominal 12 V AC output with the combined winding current capability. When connected correctly in series, they provide a nominal 24 V AC output. This makes the MV100P3S3 a practical solution for control panels and machinery incorporating compatible 12 V AC or 24 V AC equipment.
With a 100 VA rated apparent power, Class E insulation and 12% voltage regulation, the MV100P3S3 provides a flexible AC control power solution. Its compact dimensions of 85 × 70 × 93 mm and weight of 1.5 kg make it suitable for installation planning in electrical cabinets where space is limited.
The transformer is specified with EPH 1 or EPN 1 enclosure references in the ETE Stock Control Transformer Range, March 2026. Its dual-primary and dual-secondary winding arrangement offers particular value to OEMs seeking to standardise transformer selection across equipment with different supply and control voltage requirements.
The ETE MV100P3S3 uses two separate primary windings, each rated for a nominal 120 V AC. This arrangement allows the transformer to be configured for either a 120 V AC or 240 V AC input without changing the transformer itself. The required configuration is determined by how the two primary windings are connected.
For a nominal 120 V AC supply, the two primary windings are connected in parallel. Both windings operate at the same applied voltage, with the total primary current shared between them when connected correctly.
For a nominal 240 V AC supply, the two primary windings are connected in series. In this configuration, the applied voltage is distributed across the two windings so that each operates at its intended nominal voltage.
Important: Series and parallel winding connections must be made with the correct polarity and terminal identification. Incorrect wiring can cause excessive current, incorrect output voltage or transformer damage. The manufacturer's wiring diagram must be followed, and the installation should be completed by a suitably qualified person.
The MV100P3S3 also incorporates two secondary windings, each providing a nominal 12 V AC. These windings can be connected in either series or parallel, allowing the transformer to supply compatible equipment requiring different low-voltage AC control supplies.
For a nominal 12 V AC output, the secondary windings are connected in parallel. When correctly connected with matching polarity, the output voltage remains 12 V AC while the winding current capabilities are combined.
For a nominal 24 V AC output, the secondary windings are connected in series. The voltage contributions of the two 12 V windings add together, producing a nominal 24 V AC output.
This flexibility is useful for OEM machinery and electrical control panels where the same transformer design may be required to support either 12 V AC or 24 V AC control equipment. The correct secondary configuration should be selected during installation and verified before connecting the load.
The 100 VA apparent power rating applies to the transformer as a whole, not independently to each secondary winding. When the secondary windings are correctly connected in parallel for a nominal 12 V AC output, the calculated total full-load current is approximately 8.33 A.
When the secondary windings are correctly connected in series for a nominal 24 V AC output, the calculated full-load current is approximately 4.17 A.
These figures are derived from the transformer's 100 VA rating and the relevant nominal secondary voltage. They are calculated values for load assessment rather than independent confirmation of terminal current ratings or overcurrent protection requirements.
The transformer's 12% voltage regulation should also be considered when assessing connected equipment. Actual secondary voltage may vary between no-load and rated-load conditions, and the total connected load should remain within the applicable transformer rating.
Before installing the ETE MV100P3S3, confirm the available primary supply voltage, required secondary output voltage and total connected apparent power. The transformer must be configured using the correct primary and secondary winding arrangements.
For 120 V AC primary operation, connect the two 120 V primary windings in parallel according to the manufacturer's wiring diagram. For 240 V AC primary operation, connect the windings in series according to the same instructions.
For a 12 V AC secondary output, the two 12 V windings must be connected in parallel with the correct polarity. For a 24 V AC secondary output, they must be connected in series with the correct polarity so their voltages add rather than oppose one another.
Appropriate primary and secondary circuit protection, protective earthing, conductor sizing, ventilation and mechanical mounting should be incorporated into the installation design. The specified EPH 1 or EPN 1 enclosure references should be checked where additional physical protection is required.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 100 VA | |
|---|---|---|
| Primary Voltage | 0/120V + 0/120V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model | MV100P3S3 | |
| Product type | Industrial multi-voltage control transformer | |
| Transformer configuration | Dual primary windings and dual secondary windings | |
| Number of phases | Single-phase | |
| Rated apparent power | 100 VA | |
| Primary terminals | 0/120 V + 0/120 V | |
| Primary winding arrangement | Two nominal 120 V windings | |
| Primary input at 120 V AC | Windings connected in parallel | |
| Primary input at 240 V AC | Windings connected in series | |
| Secondary terminals | 0/12 V + 0/12 V | |
| Secondary winding arrangement | Two nominal 12 V windings | |
| Secondary output at 12 V AC | Windings connected in parallel | |
| Secondary output at 24 V AC | Windings connected in series | |
| Output connection | 12 V parallel or 24 V series | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | Class E | |
| Voltage regulation | 12% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding treatment | Class H varnish impregnation | |
| Core earthing | Core earth connection | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Design standard | Designed to EN 61558-1 | |
| Calculated full-load secondary current at 12 V AC | Approximately 8.33 A total, with correctly connected parallel windings | |
| Calculated full-load secondary current at 24 V AC | Approximately 4.17 A, with correctly connected series windings | |
| Calculated ideal primary current at 120 V AC | Approximately 0.83 A total, excluding losses | |
| Calculated ideal primary current at 240 V AC | Approximately 0.42 A, excluding losses | |
| Length | 85 mm | |
| Width | 70 mm | |
| Height | 93 mm | |
| Dimensions (L × W × H) | 85 × 70 × 93 mm | |
| Weight | 1.5 kg | |
| Enclosure reference | EPH 1 or EPN 1 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV100P3S3 is a 100 VA single-phase multi-voltage control transformer designed for compatible industrial electrical control circuits. Its dual primary windings support 120 V AC or 240 V AC supplies, while its dual secondary windings provide selectable 12 V AC or 24 V AC outputs.
The primary terminals are specified as 0/120 V + 0/120 V, representing two separate nominal 120 V primary windings. They can be connected in parallel for 120 V AC or in series for 240 V AC operation.
Yes. For a nominal 120 V AC primary supply, the two 120 V primary windings are connected in parallel using the correct terminal polarity and manufacturer's wiring instructions.
Yes. For a nominal 240 V AC primary supply, the two 120 V primary windings are connected in series using the correct terminal polarity and manufacturer's wiring instructions.
The secondary terminals are specified as 0/12 V + 0/12 V, representing two separate nominal 12 V secondary windings. These can be connected in parallel for 12 V AC or in series for 24 V AC output.
A nominal 12 V AC output is obtained by connecting the two 12 V secondary windings in parallel. Correct winding polarity and the manufacturer's connection diagram are essential.
A nominal 24 V AC output is obtained by connecting the two 12 V secondary windings in series, with the correct polarity so their voltages add together.
The ETE MV100P3S3 has a rated apparent power of 100 VA. This rating applies to the complete transformer rather than separately to each secondary winding.
At a nominal 12 V AC output, the 100 VA rating corresponds to approximately 8.33 A total when the secondary windings are correctly connected in parallel. This is a calculated value, not a circuit protection specification.
At a nominal 24 V AC output, the 100 VA rating corresponds to approximately 4.17 A when the secondary windings are correctly connected in series. This is a calculated value for load assessment.
The MV100P3S3 uses a Class E insulation system. ETE also specifies Class H varnish impregnation and states that the model is designed to EN 61558-1.
The ETE MV100P3S3 has a specified 12% voltage regulation. This should be considered when assessing the operating voltage tolerances of connected equipment.
The transformer measures 85 mm long, 70 mm wide and 93 mm high, with a specified weight of 1.5 kg.
The specified enclosure references are EPH 1 or EPN 1. Final enclosure selection should account for the installation environment, mechanical dimensions, ventilation and electrical safety requirements.
Correct polarity is essential when connecting transformer windings in series or parallel. Incorrect connections can produce opposing voltages, excessive circulating currents, incorrect output voltage or transformer damage. The ETE connection diagram should always be followed.
No. The ETE MV100P3S3 provides 12 V AC or 24 V AC, depending on the secondary winding configuration. Equipment requiring DC power needs an appropriate DC power supply or rectification and conditioning equipment.
When selecting the ETE MV100P3S3 100 VA transformer, verify that the intended primary supply is either 120 V AC or 240 V AC and that the connected equipment requires a nominal 12 V AC or 24 V AC output. The primary and secondary windings must be configured independently according to the required operating voltages.
The transformer's 100 VA rating, 12% voltage regulation, Class E insulation, physical dimensions and enclosure requirements should all be considered during electrical design. Connected loads must remain within the applicable transformer rating, and any significant inrush requirements should be assessed.
The ETE MV100P3S3 combines dual 120 V primary windings and dual 12 V secondary windings in a compact 100 VA control transformer. Its selectable 120 V AC or 240 V AC input and 12 V AC or 24 V AC output, together with Class E insulation, 12% voltage regulation and compact construction, make it a flexible choice for OEM machinery, industrial electrical panels and automation applications requiring configurable AC control power.