ETE MV100P2S2 is a 100 VA single-phase multi-voltage industrial control transformer with 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals. It features a tapped secondary output with a 10 V adjustment tap requiring connection confirmation with ETE, Class E insulation, 12% voltage regulation, dimensions of 85 x 70 x 93 mm, weight of 1.5 kg and EPH 1 or EPN 1 enclosure references.
£26.10
The ETE MV100P2S2 is a compact, versatile 100 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, OEM machinery and automation systems requiring flexible AC voltage connections. Part of the ETE MV multi-voltage stock control transformer range, it features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing multiple connection possibilities for appropriately designed electrical circuits.
Unlike a conventional transformer with a single fixed primary and secondary voltage, the MV100P2S2 incorporates a multi-tapped primary and secondary arrangement. This makes it particularly useful for panel builders and machinery manufacturers working with industrial supply systems and control equipment that require different nominal AC voltages. The precise voltage obtained depends on the selected terminal connections and the applied primary supply.
The transformer has a rated apparent power of 100 VA, Class E insulation and 12% voltage regulation. Its compact dimensions of 85 × 70 × 93 mm and weight of 1.5 kg make it a practical option for electrical control cabinets where installation space is limited.
A distinguishing feature of the MV100P2S2 is its 10 V secondary adjustment tap. Because the secondary terminals are marked 10/0/220/240 V, the actual terminal combinations must be confirmed against the manufacturer's datasheet. ETE should be consulted to verify the correct terminal connections before installation, particularly when using the 10 V adjustment tap.
The model is listed with EPH 1 or EPN 1 enclosure references in the ETE Stock Control Transformer Range, March 2026. It is suited to applications where the electrical designer requires a compact multi-voltage transformer rather than a fixed-output alternative.
The ETE MV100P2S2 differs from a standard single-voltage control transformer because it incorporates taps on both the primary and secondary windings. The primary terminals are identified as 20/0/380/420 V, while the secondary terminals are identified as 10/0/220/240 V. These markings are essential to correct installation and should be interpreted using the manufacturer's connection diagram.
The multi-voltage primary arrangement allows the transformer to be configured for compatible industrial AC supplies using the appropriate winding terminals. However, the terminal markings should not be treated as a list of independently selectable supply voltages without reference to the wiring diagram. The correct connection depends on the available supply voltage, intended operating configuration and manufacturer's instructions.
On the secondary side, the 10/0/220/240 V terminal arrangement provides a tapped output rather than a single fixed-voltage connection. The 10 V adjustment tap is particularly important because the voltage available between individual terminal combinations cannot be safely assumed from the terminal labels alone. Confirm the exact terminal connections with ETE before energising the transformer.
This arrangement is useful where a machinery manufacturer or panel builder requires flexibility in selecting the appropriate control circuit voltage. The transformer can form part of an industrial control power system, provided the selected connection is confirmed and the connected equipment is compatible with the resulting voltage.
The MV100P2S2 has a rated apparent power of 100 VA. The current available to a connected load depends on the actual secondary voltage selected. For example, dividing 100 VA by 240 V gives a calculated current of approximately 0.42 A, while dividing 100 VA by 220 V gives approximately 0.45 A.
These are calculated values for the stated nominal voltages, not confirmation of the correct terminal connections or a separate manufacturer-published current rating for every possible tap arrangement. The actual usable configuration and applicable load limits must be verified against the ETE datasheet.
When sizing the transformer, the combined apparent power of connected devices should be considered alongside operating voltage tolerance, starting characteristics and short-duration inrush demands. Electromagnetic contactors, relays and similar equipment may require additional consideration because their energisation demand can differ from their normal operating demand.
The specified 12% voltage regulation is another important design consideration. It describes the transformer's voltage regulation characteristic, meaning the actual secondary voltage may vary between no-load and rated-load operation. Equipment with narrow voltage tolerances should therefore be assessed carefully before connection.
The MV100P2S2 should be installed by a suitably qualified person familiar with industrial transformer wiring and electrical control circuits. Before installation, verify the available primary supply, required secondary output, total connected load and intended terminal arrangement.
Important: The 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals must be connected according to the ETE wiring diagram. The 10 V adjustment tap requires confirmation with ETE; it should not be connected based solely on an assumed voltage relationship.
Appropriate primary and secondary circuit protection, protective earthing, conductor sizing, ventilation and mechanical mounting should be incorporated into the installation design. The specified EPH 1 or EPN 1 enclosure references should be checked for suitability where an enclosed transformer arrangement is required.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 100 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model | MV100P2S2 | |
| Product type | Industrial multi-voltage control transformer | |
| Transformer configuration | Multi-tapped primary and secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 100 VA | |
| Primary terminal arrangement | 20/0/380/420 V | |
| Secondary terminal arrangement | 10/0/220/240 V | |
| Output connection | Tapped output per datasheet | |
| Secondary adjustment | 10 V adjustment tap; confirm terminal connections with ETE | |
| Input frequency | 50/60 Hz | |
| Duty | Continuous-rated control circuit transformer | |
| Insulation class | Class E | |
| Voltage regulation | 12% | |
| Terminal protection | IP20 touch-proof terminals | |
| Winding treatment | Class H varnish impregnation | |
| Core earthing | Core earth connection | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Design standard | Designed to EN 61558-1 | |
| Mounting | Suitable panel installation; DIN rail mounting option | |
| Calculated secondary current at 220 V AC | Approximately 0.45 A, based on 100 VA | |
| Calculated secondary current at 240 V AC | Approximately 0.42 A, based on 100 VA | |
| Length | 85 mm | |
| Width | 70 mm | |
| Height | 93 mm | |
| Dimensions (L × W × H) | 85 × 70 × 93 mm | |
| Weight | 1.5 kg | |
| Enclosure reference | EPH 1 or EPN 1 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV100P2S2 is a 100 VA single-phase multi-voltage control transformer intended for compatible industrial electrical control panels, OEM machinery and auxiliary circuits. Its tapped primary and secondary arrangements provide flexibility when selecting suitable AC voltage connections.
The primary terminal arrangement is 20/0/380/420 V. The correct connections must be selected according to the available AC supply and the manufacturer's wiring diagram.
The secondary terminal arrangement is 10/0/220/240 V. The transformer has a tapped secondary output, and the correct terminal combinations must be confirmed against the ETE datasheet.
No. The MV100P2S2 is specified with a tapped output per datasheet, rather than a single fixed output connection. The resulting voltage depends on the selected primary and secondary terminal connections.
The transformer includes a 10 V adjustment tap within its secondary terminal arrangement. Its exact use and the correct terminal combinations must be confirmed with ETE before installation. Do not assume the connection method from the terminal markings alone.
The ETE MV100P2S2 has a rated apparent power of 100 VA. The connected load must remain within the applicable transformer rating and operating limits.
At a nominal 240 V AC, a 100 VA rating corresponds to approximately 0.42 A, calculated by dividing 100 VA by 240 V. This calculation does not establish which terminal combination should be used.
At a nominal 220 V AC, a 100 VA rating corresponds to approximately 0.45 A, calculated by dividing 100 VA by 220 V. The correct secondary connection must still be verified against the manufacturer's documentation.
The MV100P2S2 has a Class E insulation system. ETE also specifies Class H varnish impregnation and states that the model is designed to EN 61558-1.
The ETE MV100P2S2 has a specified 12% voltage regulation. This should be considered when assessing the permissible operating voltage range of connected control equipment.
The transformer measures 85 mm long, 70 mm wide and 93 mm high, with a specified weight of 1.5 kg.
The specified enclosure references are EPH 1 or EPN 1. Final enclosure selection should account for the installation environment, mechanical dimensions, ventilation and electrical safety requirements.
ETE lists a DIN rail mounting option for the MV100P2S2. The appropriate mounting arrangement and components should be confirmed before installation.
No. The ETE MV100P2S2 is an AC control transformer. Equipment requiring DC power needs a suitable DC power supply or appropriately designed rectification and conditioning equipment.
The MV100P2S2 has an unusual 20/0/380/420 V primary and 10/0/220/240 V secondary terminal arrangement, including a 10 V adjustment tap. Confirming the connection diagram with ETE helps ensure that the intended voltage is obtained without relying on assumptions about the tap relationships.
When selecting the ETE MV100P2S2 100 VA transformer, confirm that the required primary and secondary voltages can be achieved using the manufacturer's approved terminal connections. The multi-tapped design offers flexibility, but it is essential to distinguish between terminal markings and confirmed operating configurations.
The transformer's 100 VA rating, 12% voltage regulation, Class E insulation and compact dimensions should all be considered during electrical design. Where the 10 V adjustment tap is required, obtain the correct connection details from ETE before proceeding.
The ETE MV100P2S2 combines a 100 VA rating with multi-tapped primary and secondary windings, Class E insulation, 12% voltage regulation and compact construction. Its 20/0/380/420 V primary and 10/0/220/240 V secondary terminal arrangements make it a flexible option for industrial control panels and OEM machinery, provided the intended connections, including the 10 V adjustment tap, are verified with ETE.