Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE MV1000P1S1 is a 1000 VA single-phase multi-voltage control transformer with 10/0/220/240 V primary terminals, selectable 55 V AC or 110 V AC secondary taps, Class E insulation and 4% voltage regulation for industrial control applications.
£117.68
The ETE MV1000P1S1 is a robust 1000 VA (1 kVA) single-phase multi-voltage control transformer designed to provide reliable electrical isolation and selectable AC control voltages for industrial machinery, electrical control panels and automation systems. Part of the ETE MV Multi-Voltage transformer series, it features primary terminals marked 10/0/220/240 V and secondary terminals marked 0/55/110 V, allowing the selection of nominal 55 V AC or 110 V AC output connections.
Manufactured by Eastern Transformers & Equipment (ETE), the MV1000P1S1 is suitable for industrial installations requiring a dedicated control transformer with flexible primary voltage connections. Its primary winding incorporates nominal 220 V and 240 V connections, together with a 10 V primary adjustment tap whose correct terminal arrangement must be confirmed with ETE before installation.
With a rated capacity of 1000 VA, Class E insulation and 4% voltage regulation, the MV1000P1S1 combines substantial control power capability with practical voltage selection. Measuring 150 × 125 × 145 mm and weighing 9.8 kg, it is designed for integration into appropriately engineered industrial electrical equipment. The specified enclosure reference is EPN 3.
The ETE MV1000P1S1 features primary terminals marked 10/0/220/240 V, providing nominal 220 V and 240 V primary connection options alongside a 10 V adjustment tap.
This configuration makes the transformer suitable for electrical control systems where the available nominal supply voltage must be matched to the transformer connection. The appropriate primary terminals should be selected according to the supply voltage and the manufacturer's connection documentation.
The 10 V primary adjustment tap provides additional connection flexibility. However, the precise use of this adjustment tap and its relationship to the other primary terminals must be confirmed with ETE. It should not be treated as an independent 10 V output or connected on the basis of assumed terminal relationships.
The primary terminals are fixed winding connections rather than an automatic voltage-ranging input. All connections must be verified before the transformer is energised.
The MV1000P1S1 has secondary terminals marked 0/55/110 V, allowing the installer to select the required nominal secondary voltage for compatible industrial control equipment.
Unlike transformers with two separately specified secondary windings, the MV1000P1S1 is described with a single tapped secondary terminal arrangement. The 55 V and 110 V connections should therefore be selected according to ETE's wiring documentation rather than treated as independent outputs with separate full-power ratings.
The 1000 VA rating applies to the transformer as a whole. Connected loads must remain within the applicable transformer and winding limits, with suitable circuit protection and conductor sizing.
The ETE MV1000P1S1 has a specified 4% voltage regulation, describing the change in secondary voltage between the manufacturer's defined loading conditions. This characteristic is useful when selecting a transformer for control circuits where load demand may vary during operation.
Combined with its Class E insulation system, 1 kVA capacity and selectable secondary voltage taps, the transformer provides a practical solution for industrial electrical installations requiring isolated AC control power.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 1000 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | MV Multi-Voltage Transformers | |
| Model | MV1000P1S1 | |
| Product type | Multi-voltage control transformer | |
| Transformer configuration | Single-phase | |
| Rated apparent power | 1000 VA (1 kVA) | |
| Primary terminals | 10/0/220/240 V | |
| Primary nominal voltage connections | 220 V and 240 V | |
| Primary adjustment tap | 10 V; confirm connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary output connections | 55 V or 110 V taps | |
| Voltage regulation | 4% | |
| Insulation class | E | |
| Enclosure reference | EPN 3 | |
| Length | 150 mm | |
| Width | 125 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 125 × 145 mm | |
| Weight | 9.8 kg | |
| Manufacturer range | ETE stock control transformer range | |
| Specification reference | ETE stock control transformer price list, March 2026 |
The ETE MV1000P1S1 is a 1000 VA single-phase multi-voltage control transformer used to provide isolated 55 V AC or 110 V AC power for compatible industrial control circuits, machinery and electrical equipment.
The transformer has primary terminals marked 10/0/220/240 V, incorporating nominal 220 V and 240 V connections and a 10 V primary adjustment tap. The correct terminal arrangement must be confirmed with ETE.
The 10 V primary adjustment tap provides additional flexibility in the primary winding connection arrangement. The correct terminal connections and intended use must be confirmed with ETE before installation.
The MV1000P1S1 has secondary terminals marked 0/55/110 V, providing selectable nominal 55 V AC or 110 V AC output connections when correctly supplied and connected.
The manufacturer's specification identifies secondary terminals marked 0/55/110 V with selectable 55 V or 110 V taps. It does not specify two independent secondary windings. The correct connection arrangement should be confirmed using ETE's documentation.
The transformer has a rated apparent power of 1000 VA (1 kVA), suitable for compatible industrial control loads within its specified capacity.
The transformer has a specified 4% voltage regulation, describing the change in secondary voltage between the manufacturer's defined loading conditions.
The MV1000P1S1 measures 150 × 125 × 145 mm (L × W × H) and weighs 9.8 kg. Appropriate mechanical support and secure installation should be provided.
The transformer features a Class E insulation system, providing a defined insulation classification for industrial transformer applications.
The manufacturer's specified enclosure reference is EPN 3. This reference should be used when confirming suitable protective enclosure arrangements with ETE.
ETE MV multi-voltage transformers provide flexible voltage connections, dependable electrical isolation and robust construction for industrial control applications. The MV1000P1S1 combines a 1000 VA rating, 10/0/220/240 V primary terminals and selectable 55 V AC or 110 V AC secondary connections with Class E insulation and 4% voltage regulation, making it a practical choice for professional electrical panel builders and industrial equipment manufacturers.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.