Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE DV750P6S6 is a 750 VA single-phase dual-input-voltage control transformer with 0/240/415 V primary terminals, a 24 V AC secondary output, Class E insulation, 4% voltage regulation and EPN 3 enclosure reference.
£102.23
The ETE DV750P6S6 is a robust 750 VA single-phase dual-input-voltage control transformer designed to provide a nominal 24 V AC secondary supply for industrial machinery, electrical control panels and automation systems. Part of the ETE DV transformer series, it accommodates nominal 240 V and 415 V AC primary supplies through its dedicated input terminals.
Featuring 0/240/415 V primary terminals and 0/24 V secondary terminals, the DV750P6S6 provides flexible input voltage selection while maintaining a dedicated 24 V AC output. Its separate primary and secondary windings provide electrical isolation, making it suitable for supplying compatible low-voltage control circuits.
With Class E insulation, 4% voltage regulation and a substantial 750 VA capacity, this transformer is designed for demanding industrial control applications. Its dimensions of 150 × 108 × 145 mm, weight of 7.6 kg and specified EPN 3 enclosure reference make it a practical choice for professionally designed electrical installations.
The ETE DV750P6S6 converts electrical power from a correctly selected 240 V or 415 V AC primary connection to a nominal 24 V AC secondary supply. Its dual-input arrangement helps standardise transformer selection across industrial equipment operating from different supply voltages. The appropriate primary terminals must be selected before energising the transformer.
At its rated 750 VA capacity, the transformer has a calculated nominal secondary current of 31.25 A at 24 V AC. The specified 4% voltage regulation describes secondary voltage variation between no-load and rated-load operation. Suitable overcurrent protection, wiring and load assessment remain essential for safe installation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 750 VA | |
|---|---|---|
| Primary Voltage | 0/240/415V | |
| Secondary Voltage | 0/24V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | DV Dual-Input-Voltage Control Transformers | |
| Model / SKU | DV750P6S6 | |
| Product type | Dual-input-voltage control transformer | |
| Phases | Single-phase | |
| Rated apparent power | 750 VA | |
| Primary terminals | 0/240/415 V | |
| Nominal primary voltage options | 240 V AC or 415 V AC | |
| Secondary terminals | 0/24 V | |
| Output connection | 24 V | |
| Nominal secondary voltage | 24 V AC | |
| Calculated nominal full-load secondary current | 31.25 A | |
| Insulation class | E | |
| Voltage regulation | 4% | |
| Enclosure reference | EPN 3 | |
| Length | 150 mm | |
| Width | 108 mm | |
| Height | 145 mm | |
| Weight | 7.6 kg | |
| Product range | ETE Stock Control Transformer Range | |
| Specification reference | ETE Price List March 2026 |
The ETE DV750P6S6 is a 750 VA single-phase dual-input-voltage control transformer used to supply nominal 24 V AC power to compatible industrial control equipment.
It features 0/240/415 V primary terminals, allowing selection of a nominal 240 V or 415 V AC primary connection.
The transformer has 0/24 V secondary terminals and a nominal 24 V AC output.
Its 750 VA rating corresponds to a calculated nominal secondary current of 31.25 A at 24 V AC.
The transformer has Class E insulation, 4% voltage regulation, dimensions of 150 × 108 × 145 mm, a weight of 7.6 kg and an EPN 3 enclosure reference.
The ETE DV750P6S6 combines flexible 240 V or 415 V AC primary connections with a dedicated 24 V AC output, 750 VA capacity and 4% voltage regulation, making it a practical transformer for industrial control panel and machinery applications.
The ETE XMS150P5S4 is a 150 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 110 V AC secondary output from a 415 V AC primary supply. Part of the ETE XMS series, it offers an enclosed transformer solution for industrial control panels, machinery and electrical automation systems.
Its 0/415 V primary terminals and 0/110 V secondary terminals provide a dedicated voltage conversion arrangement. The transformer's Class II construction incorporates protective insulation that does not rely on a protective earth connection for protection against electric shock.
With Class F insulation, an integral moulded housing and the choice of DIN rail or chassis mounting, the XMS150P5S4 is designed for flexible integration into industrial electrical cabinets. It measures 102 × 115.5 × 106 mm and weighs 3 kg.
The ETE XMS150P5S4 uses separate primary and secondary windings to provide electrical isolation while converting a nominal 415 V AC supply into a nominal 110 V AC output. Its enclosed construction and Class II protective insulation make it suitable for appropriately designed industrial control equipment where this form of electrical protection is required.
At 150 VA, the calculated nominal full-load secondary current is approximately 1.36 A at 110 V AC. The Class F insulation and integral moulded housing support industrial installation, while DIN rail or chassis mounting provides flexibility. Correct circuit protection and compliance with the manufacturer's installation requirements remain essential.
It is a 150 VA Class II enclosed safety/isolating transformer designed to supply nominal 110 V AC power from a 415 V AC input for compatible industrial control equipment.
It has 0/415 V primary terminals and 0/110 V secondary terminals, providing a nominal 110 V AC output.
Class II construction means the transformer incorporates protective insulation that does not rely on a protective earth connection for protection against electric shock.
Yes. The transformer supports DIN rail or chassis mounting and features an integral moulded housing.
It is rated at 150 VA, uses Class F insulation, measures 102 × 115.5 × 106 mm and weighs 3 kg.
The ETE XMS150P5S4 provides an enclosed Class II transformer solution combining a 415 V AC primary input, 110 V AC output, 150 VA rating, Class F insulation and flexible DIN rail or chassis mounting for industrial control applications.
The ETE XMS150P4S4 is a compact 150 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 110 V AC secondary output from a 240 V AC primary supply. Part of the ETE XMS transformer series, it offers an enclosed and electrically isolated power source for industrial machinery, electrical control panels and automation equipment.
The transformer features 0/240 V primary terminals and 0/110 V secondary terminals. Its Class II construction incorporates protective insulation that does not depend on a protective earth connection for protection against electric shock, making it suitable for installations requiring this equipment classification.
With Class F insulation, an integral moulded housing and DIN rail or chassis mounting, the ETE XMS150P4S4 offers convenient installation flexibility. Measuring 102 × 115.5 × 106 mm and weighing 3 kg, it is suited to professionally designed industrial electrical cabinets.
The ETE XMS150P4S4 converts a nominal 240 V AC primary supply into a nominal 110 V AC secondary output using separate transformer windings. This provides galvanic isolation between the input and output circuits, making it suitable for appropriately designed industrial electrical control systems.
Its 150 VA capacity corresponds to a calculated nominal full-load secondary current of approximately 1.36 A at 110 V AC. The integral moulded housing, Class II protective insulation and DIN rail or chassis mounting support practical installation. Correct circuit protection, load selection and adherence to installation instructions remain essential.
It is a 150 VA Class II enclosed safety/isolating transformer designed to provide 110 V AC power from a 240 V AC supply for compatible industrial control equipment.
The transformer features 0/240 V primary terminals and 0/110 V secondary terminals, providing a nominal 110 V AC output.
Class II means the transformer incorporates a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
The transformer supports DIN rail or chassis mounting and features an integral moulded housing.
It measures 102 × 115.5 × 106 mm, weighs 3 kg and uses Class F insulation.
The ETE XMS150P4S4 combines a 150 VA rating, 240 V AC primary input, 110 V AC secondary output, Class II enclosed construction and flexible DIN rail or chassis mounting for practical industrial control power applications.
The ETE MV300P1S1 is a versatile 300 VA single-phase multi-voltage control transformer designed to provide selectable 55 V AC or 110 V AC secondary outputs for industrial electrical control equipment. Part of the ETE MV multi-voltage transformer series, it is suitable for machinery, control panels and automation systems requiring different low-voltage AC supply options.
The transformer features 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. Its tapped secondary winding provides 55 V or 110 V output connections, allowing the appropriate nominal secondary voltage to be selected for compatible equipment.
With a 300 VA rating, Class E insulation and 8% voltage regulation, the ETE MV300P1S1 offers practical industrial control power conversion. It measures 120 × 100 × 120 mm, weighs 4.7 kg and has specified EPH 3 or EPN 2 enclosure references. Its 10 V primary adjustment tap requires connection confirmation with ETE before installation.
The ETE MV300P1S1 uses a tapped secondary winding to provide nominal 55 V AC and 110 V AC output options. This makes it useful where industrial control equipment requires one of these voltage levels. Its 10/0/220/240 V primary terminal arrangement also provides the specified multi-voltage input configuration, including a 10 V adjustment tap.
The transformer is rated at 300 VA, with a calculated nominal full-load current of approximately 2.73 A at 110 V AC. The permissible load on the 55 V tap must be established from the manufacturer's winding and tapping instructions rather than assuming the full 300 VA rating is available from every tap. Confirm the 10 V primary adjustment tap connections with ETE before energising the transformer.
It is a 300 VA single-phase multi-voltage control transformer designed to supply nominal 55 V or 110 V AC power to compatible industrial control equipment.
The transformer features 10/0/220/240 V primary terminals, including a 10 V adjustment tap. The correct connections must be confirmed with ETE.
Its 0/55/110 V secondary terminals provide nominal 55 V AC or 110 V AC output taps.
The transformer is rated at 300 VA, incorporates Class E insulation and has 8% voltage regulation.
The ETE MV300P1S1 measures 120 × 100 × 120 mm, weighs 4.7 kg and specifies EPH 3 or EPN 2 enclosure references.
The ETE MV300P1S1 combines a 300 VA rating, selectable 55 V and 110 V AC secondary taps, Class E insulation and 8% voltage regulation, offering flexible voltage conversion for industrial machinery and electrical control systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.