ETE DV400P6S5 is a 400 VA single-phase dual-input-voltage industrial control transformer with selectable 240 V AC or 415 V AC primary connections, a nominal 240 V AC secondary output, Class E insulation, 8% voltage regulation, dimensions of 120 x 108 x 120 mm, weight of 5.5 kg and EPH 3 or EPN 2 enclosure references.
£65.03
The ETE DV400P6S5 is a versatile 400 VA single-phase industrial control transformer designed to provide a nominal 240 V AC secondary output from either a 240 V AC or 415 V AC primary supply. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the established ETE DV dual-input-voltage stock control transformer range, developed for electrical panel builders, machinery manufacturers, OEMs and industrial automation applications requiring flexible primary voltage connections.
Featuring a 0/240/415 V primary terminal configuration, the DV400P6S5 allows the appropriate input connection to be selected according to the available supply voltage. Its 0/240 V secondary terminals provide a single nominal 240 V AC output, making it suitable for compatible control circuits, switching equipment and auxiliary electrical loads. The dual-input design helps standardise transformer selection across machinery and control panels intended for different industrial electrical supplies.
With a rated apparent power of 400 VA, Class E insulation and 8% voltage regulation, the ETE DV400P6S5 provides a practical solution for control systems requiring a dedicated AC supply. Its continuous-duty design, IP20 touch-proof terminals, Class H varnish impregnation and core earth connection support installation in appropriately designed industrial electrical assemblies.
The transformer measures 120 × 108 × 120 mm and weighs 5.5 kg. Its specified EPH 3 or EPN 2 enclosure references make it suitable for consideration in electrical control cabinets, machinery panels and appropriately enclosed transformer installations.
The ETE DV400P6S5 is designed for industrial electrical installations where the available primary supply may be either 240 V AC or 415 V AC. Its primary winding features 0/240/415 V terminals, allowing the correct connection to be selected during installation. When supplied through the appropriate primary terminals, the transformer provides a nominal 240 V AC secondary output through its 0/240 V terminals.
This dual-input arrangement is useful for electrical panel builders and OEM machinery manufacturers producing equipment for different supply configurations. On a 415 V AC supply, the transformer performs a step-down conversion to 240 V AC. On a 240 V AC supply, it provides a nominal 240 V AC secondary output through the transformer. The two primary voltage options are alternative connections and must not be treated as independent supplies that can be connected simultaneously.
The 400 VA rating corresponds to a calculated nominal full-load secondary current of approximately 1.67 A at 240 V AC. This value is obtained by dividing the transformer's rated apparent power by its nominal secondary voltage. Engineers should consider the total connected apparent power, load power factor, permissible voltage variation and any short-duration inrush requirements when determining whether the DV400P6S5 is suitable for a particular application.
The specified 8% voltage regulation is an important consideration for control circuits with defined operating voltage tolerances. Voltage regulation relates to the change in secondary voltage between no-load and rated-load conditions under the relevant test conditions. The actual secondary voltage may therefore vary with primary supply voltage and connected load rather than remaining exactly 240 V AC at all times.
The DV400P6S5 incorporates Class E insulation, IP20 touch-proof terminals, Class H varnish impregnation and a core earth connection. For installations requiring additional protection, the specified enclosure references are EPH 3 or EPN 2. Appropriate primary and secondary overcurrent protection, conductor sizing, protective earthing, ventilation and mounting arrangements must be considered during installation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 400 VA | |
|---|---|---|
| Primary Voltage | 0/240/415V | |
| Secondary Voltage | 0/240V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | DV Dual-Input-Voltage Stock Control Transformer Range | |
| Model | DV400P6S5 | |
| Product type | Industrial control circuit transformer | |
| Transformer configuration | Dual-input-voltage primary, single-voltage secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 400 VA | |
| Primary voltage options | 240 V AC or 415 V AC | |
| Primary terminals | 0/240/415 V | |
| Secondary voltage | 240 V AC | |
| Secondary terminals | 0/240 V | |
| Output connection | 240 V | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | Class E | |
| Varnish impregnation | Class H | |
| Voltage regulation | 8% | |
| Terminal protection | IP20 touch-proof terminals | |
| Core earthing | Core earth connection | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Design standard | EN 61558-1 | |
| Calculated full-load secondary current | Approximately 1.67 A | |
| Calculated ideal primary current at 240 V AC | Approximately 1.67 A, excluding losses | |
| Calculated ideal primary current at 415 V AC | Approximately 0.96 A, excluding losses | |
| Length | 120 mm | |
| Width | 108 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 108 × 120 mm | |
| Weight | 5.5 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Installation type | Electrical control panel or suitable enclosure installation | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE DV400P6S5 is a 400 VA single-phase dual-input-voltage control transformer designed to provide a nominal 240 V AC output from either a 240 V AC or 415 V AC primary supply. It is suitable for compatible industrial machinery control circuits and auxiliary electrical equipment.
Dual-input voltage means the transformer has 0/240/415 V primary terminals, allowing the appropriate connection to be selected for either a 240 V AC or 415 V AC supply. Only the correct primary connection for the available supply should be used.
The ETE DV400P6S5 has a rated apparent power of 400 VA. The combined connected load must remain within the transformer's rating and applicable operating limits.
The transformer has 0/240/415 V primary terminals and 0/240 V secondary terminals. When correctly connected to either supported primary supply voltage, it provides a nominal 240 V AC secondary output.
Based on its 400 VA rating and 240 V AC secondary voltage, the calculated full-load secondary current is approximately 1.67 A. Actual transformer selection should also account for connected load characteristics and inrush requirements.
The DV400P6S5 uses a Class E insulation system. The ETE DV transformer range is described as being designed to EN 61558-1 and incorporating protective Class H varnish impregnation.
The transformer measures 120 mm long, 108 mm wide and 120 mm high, with a specified weight of 5.5 kg.
The ETE DV400P6S5 has a specified 8% voltage regulation. This should be considered when assessing the secondary voltage requirements of connected equipment under different load conditions.
The specified enclosure references are EPH 3 or EPN 2. The correct enclosure should be selected according to the installation environment, transformer dimensions, ventilation requirements and applicable electrical safety regulations.
Yes. The DV400P6S5 is intended for industrial control applications and can be incorporated into a suitably designed electrical control panel or enclosure, subject to appropriate mounting, ventilation, circuit protection and protective earthing.
No. The ETE DV400P6S5 provides a nominal 240 V AC secondary output, not 240 V DC. Applications requiring direct current need a suitable DC power supply or appropriately rated rectification and conditioning equipment.
No. The 0/240/415 V primary terminals provide alternative connections for the two supported input voltages. The transformer must be connected using the correct terminals for the available supply, following the manufacturer's instructions. It is not designed to combine two independent primary supplies.
When selecting the ETE DV400P6S5 400 VA transformer, confirm that the available primary supply is either 240 V AC or 415 V AC and that the connected equipment requires a nominal 240 V AC supply. The transformer's 400 VA apparent power rating must be sufficient for the combined operating loads, with appropriate consideration given to inrush currents and operating conditions.
Its 8% voltage regulation, Class E insulation, dimensions and enclosure requirements should also be considered during electrical design. The specified EPH 3 or EPN 2 enclosure references provide a starting point for enclosure selection, while final installation arrangements should be checked against the manufacturer's documentation and applicable electrical regulations.
The ETE DV400P6S5 combines dual-input-voltage flexibility with a 400 VA rating and a nominal 240 V AC secondary output. Its selectable 240 V AC or 415 V AC primary connection, Class E insulation, 8% voltage regulation and industrial construction make it a practical choice for electrical control panels, OEM machinery and automation applications requiring a dedicated AC control supply.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.